Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)

During daily practice, we find various situations in which the 1/1 correspondence between panoramic x-ray (OPG) and reality seems not to be respected. In the studied literature, there are articles on this subject, but our study was made based on cases in a highly frequented dental imaging clinic in...

Full description

Bibliographic Details
Main Authors: Tonea Marinela, Ivanciu Crina, Trascu C., Dogioiu F.C., Damian I., Cosconel Cristiana, Epistatu D.
Format: Article
Language:English
Published: Sciendo 2016-08-01
Series:ARS Medica Tomitana
Subjects:
Online Access:https://doi.org/10.1515/arsm-2016-0033
id doaj-d13acba388f544a19d556418d05db16c
record_format Article
spelling doaj-d13acba388f544a19d556418d05db16c2021-09-06T19:40:04ZengSciendoARS Medica Tomitana1841-40362016-08-0122319620210.1515/arsm-2016-0033arsm-2016-0033Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)Tonea Marinela0Ivanciu Crina1Trascu C.2Dogioiu F.C.3Damian I.4Cosconel Cristiana5Epistatu D.6 Carol Davila University of Medicine and Pharmacy, Bucharest Carol Davila University of Medicine and Pharmacy, Bucharest Carol Davila University of Medicine and Pharmacy, Bucharest Carol Davila University of Medicine and Pharmacy, Bucharest Faculty of Medicine, “Ovidius” University, Constanta Carol Davila University of Medicine and Pharmacy, Bucharest Carol Davila University of Medicine and Pharmacy, BucharestDuring daily practice, we find various situations in which the 1/1 correspondence between panoramic x-ray (OPG) and reality seems not to be respected. In the studied literature, there are articles on this subject, but our study was made based on cases in a highly frequented dental imaging clinic in Bucharest. The study was carried out on a number of 24 patients selected from the radiology department. Using Romexis Viewer software, with soft’s specific feature, measurements have been made (in approximately horizontal and approximately vertical axis) in three different areas: anterior, bicuspid and molar. Various results have been obtained, depending on the studied area. CBCT measured length of anterior teeth was higher than that measured on OPG, in the majority of cases. Molar width (mesio-distal distance) parameter variation was very small between OPG and CBCT.https://doi.org/10.1515/arsm-2016-0033panoramic radiographycbctdimensional measurements
collection DOAJ
language English
format Article
sources DOAJ
author Tonea Marinela
Ivanciu Crina
Trascu C.
Dogioiu F.C.
Damian I.
Cosconel Cristiana
Epistatu D.
spellingShingle Tonea Marinela
Ivanciu Crina
Trascu C.
Dogioiu F.C.
Damian I.
Cosconel Cristiana
Epistatu D.
Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)
ARS Medica Tomitana
panoramic radiography
cbct
dimensional measurements
author_facet Tonea Marinela
Ivanciu Crina
Trascu C.
Dogioiu F.C.
Damian I.
Cosconel Cristiana
Epistatu D.
author_sort Tonea Marinela
title Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)
title_short Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)
title_full Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)
title_fullStr Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)
title_full_unstemmed Comparative dimensional study between panoramic X-ray (OPG) and cone beam CT (CBCT)
title_sort comparative dimensional study between panoramic x-ray (opg) and cone beam ct (cbct)
publisher Sciendo
series ARS Medica Tomitana
issn 1841-4036
publishDate 2016-08-01
description During daily practice, we find various situations in which the 1/1 correspondence between panoramic x-ray (OPG) and reality seems not to be respected. In the studied literature, there are articles on this subject, but our study was made based on cases in a highly frequented dental imaging clinic in Bucharest. The study was carried out on a number of 24 patients selected from the radiology department. Using Romexis Viewer software, with soft’s specific feature, measurements have been made (in approximately horizontal and approximately vertical axis) in three different areas: anterior, bicuspid and molar. Various results have been obtained, depending on the studied area. CBCT measured length of anterior teeth was higher than that measured on OPG, in the majority of cases. Molar width (mesio-distal distance) parameter variation was very small between OPG and CBCT.
topic panoramic radiography
cbct
dimensional measurements
url https://doi.org/10.1515/arsm-2016-0033
work_keys_str_mv AT toneamarinela comparativedimensionalstudybetweenpanoramicxrayopgandconebeamctcbct
AT ivanciucrina comparativedimensionalstudybetweenpanoramicxrayopgandconebeamctcbct
AT trascuc comparativedimensionalstudybetweenpanoramicxrayopgandconebeamctcbct
AT dogioiufc comparativedimensionalstudybetweenpanoramicxrayopgandconebeamctcbct
AT damiani comparativedimensionalstudybetweenpanoramicxrayopgandconebeamctcbct
AT cosconelcristiana comparativedimensionalstudybetweenpanoramicxrayopgandconebeamctcbct
AT epistatud comparativedimensionalstudybetweenpanoramicxrayopgandconebeamctcbct
_version_ 1717769391191359488