Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facility

This paper reports the results of different heat emitter system measurements, which were carried out at the nZEB test facility near Tallinn University of Technology in early 2018. Radiators, underfloor heating, air heaters and radiant ceiling panels are studied as coupled with different control sche...

Full description

Bibliographic Details
Main Authors: Võsa Karl-Villem, Ferrantelli Andrea, Kurnitski Jarek
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/37/e3sconf_clima2019_04005.pdf
id doaj-d1bf182890e64e679192eb46ef8bc189
record_format Article
spelling doaj-d1bf182890e64e679192eb46ef8bc1892021-02-02T01:47:04ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011110400510.1051/e3sconf/201911104005e3sconf_clima2019_04005Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facilityVõsa Karl-Villem0Ferrantelli Andrea1Kurnitski JarekNearly Zero Energy Buildings Research Group, Ehitajate tee 5, 19086 Tallinn, Tallinn University of TechnologyNearly Zero Energy Buildings Research Group, Ehitajate tee 5, 19086 Tallinn, Tallinn University of TechnologyThis paper reports the results of different heat emitter system measurements, which were carried out at the nZEB test facility near Tallinn University of Technology in early 2018. Radiators, underfloor heating, air heaters and radiant ceiling panels are studied as coupled with different control schemes ranging from ON-OFF to PI-type control. The objective is to assess and quantify the control accuracy and thermal comfort parameters among different configurations. Scheduled heating dummies are used to simulate internal heat gains within the otherwise unoccupied test rooms. Along with outdoor temperature variation, the heating demand is therefore constantly changing and the control systems are continuously adjusting the heat output to maintain the desired indoor air temperatures. Control accuracy is then determined from the temperature deviations against this set value. Air stratification within the room is assessed with vertical temperature gradient calculations from measured air temperatures at different heights. The operative temperature at the point of expected occupancy is calculated from surrounding air and enclosing surface temperatures. The quantified results provide a comprehensive comparison between the different system configurations, enabling further energy simulations in related software packages since these parameters directly influence the energy usage within a system.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/37/e3sconf_clima2019_04005.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Võsa Karl-Villem
Ferrantelli Andrea
Kurnitski Jarek
spellingShingle Võsa Karl-Villem
Ferrantelli Andrea
Kurnitski Jarek
Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facility
E3S Web of Conferences
author_facet Võsa Karl-Villem
Ferrantelli Andrea
Kurnitski Jarek
author_sort Võsa Karl-Villem
title Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facility
title_short Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facility
title_full Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facility
title_fullStr Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facility
title_full_unstemmed Experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in TUT nZEB test facility
title_sort experimental study of radiator, underfloor, ceiling and air heater systems heat emission performance in tut nzeb test facility
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2019-01-01
description This paper reports the results of different heat emitter system measurements, which were carried out at the nZEB test facility near Tallinn University of Technology in early 2018. Radiators, underfloor heating, air heaters and radiant ceiling panels are studied as coupled with different control schemes ranging from ON-OFF to PI-type control. The objective is to assess and quantify the control accuracy and thermal comfort parameters among different configurations. Scheduled heating dummies are used to simulate internal heat gains within the otherwise unoccupied test rooms. Along with outdoor temperature variation, the heating demand is therefore constantly changing and the control systems are continuously adjusting the heat output to maintain the desired indoor air temperatures. Control accuracy is then determined from the temperature deviations against this set value. Air stratification within the room is assessed with vertical temperature gradient calculations from measured air temperatures at different heights. The operative temperature at the point of expected occupancy is calculated from surrounding air and enclosing surface temperatures. The quantified results provide a comprehensive comparison between the different system configurations, enabling further energy simulations in related software packages since these parameters directly influence the energy usage within a system.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/37/e3sconf_clima2019_04005.pdf
work_keys_str_mv AT vosakarlvillem experimentalstudyofradiatorunderfloorceilingandairheatersystemsheatemissionperformanceintutnzebtestfacility
AT ferrantelliandrea experimentalstudyofradiatorunderfloorceilingandairheatersystemsheatemissionperformanceintutnzebtestfacility
AT kurnitskijarek experimentalstudyofradiatorunderfloorceilingandairheatersystemsheatemissionperformanceintutnzebtestfacility
_version_ 1724311110014730240