Temporary electrical installations by contractors in power plants and industry
The paper deals with the topic of the installation and connection of temporary field electrical installations by external contractors in power plants and large industrial plants. One of the possible solutions and a detailed description of the equipment are recommended, and a way of connecting and in...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Electrical Engineering Institute Nikola Tesla
2017-01-01
|
Series: | Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" |
Subjects: | |
Online Access: | http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2017/0350-85281727057S.pdf |
id |
doaj-d1f6fbc61e144beba864a2d54cf07235 |
---|---|
record_format |
Article |
spelling |
doaj-d1f6fbc61e144beba864a2d54cf072352020-11-25T00:34:29ZengElectrical Engineering Institute Nikola TeslaZbornik Radova: Elektrotehnički Institut "Nikola Tesla"0350-85282406-12122017-01-012727576910.5937/zeint27-155920350-85281727057STemporary electrical installations by contractors in power plants and industrySimić Ninoslav0Mrvić Jovan1Jasika Ranko2University of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaThe paper deals with the topic of the installation and connection of temporary field electrical installations by external contractors in power plants and large industrial plants. One of the possible solutions and a detailed description of the equipment are recommended, and a way of connecting and installing of a temporary field electrical installation is given. The distribution of a temporary field electrical installation containing connecting cables, a main distribution cabinet with associated protective devices, isolation and instrument transformers, electrical installations from the contractor's distribution cabinets to the other distribution cabinet and the junction box is described. The significance of the contractor's training was recognized and, on a characteristic example, an explanation of possible synchronization of still valid rules and new standards regarding the application of the protective measure - electrical separation was shown on a characteristic example. The boundaries of the contractor's responsibility regarding the correctness of electrical installations are clearly given. Finally, one way of running and connecting a temporary electrical installation is proposed in accordance with applicable laws, regulations and standards.http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2017/0350-85281727057S.pdflow voltage electrical installationsprotection against electric shockconstruction installations |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Simić Ninoslav Mrvić Jovan Jasika Ranko |
spellingShingle |
Simić Ninoslav Mrvić Jovan Jasika Ranko Temporary electrical installations by contractors in power plants and industry Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" low voltage electrical installations protection against electric shock construction installations |
author_facet |
Simić Ninoslav Mrvić Jovan Jasika Ranko |
author_sort |
Simić Ninoslav |
title |
Temporary electrical installations by contractors in power plants and industry |
title_short |
Temporary electrical installations by contractors in power plants and industry |
title_full |
Temporary electrical installations by contractors in power plants and industry |
title_fullStr |
Temporary electrical installations by contractors in power plants and industry |
title_full_unstemmed |
Temporary electrical installations by contractors in power plants and industry |
title_sort |
temporary electrical installations by contractors in power plants and industry |
publisher |
Electrical Engineering Institute Nikola Tesla |
series |
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" |
issn |
0350-8528 2406-1212 |
publishDate |
2017-01-01 |
description |
The paper deals with the topic of the installation and connection of temporary field electrical installations by external contractors in power plants and large industrial plants. One of the possible solutions and a detailed description of the equipment are recommended, and a way of connecting and installing of a temporary field electrical installation is given. The distribution of a temporary field electrical installation containing connecting cables, a main distribution cabinet with associated protective devices, isolation and instrument transformers, electrical installations from the contractor's distribution cabinets to the other distribution cabinet and the junction box is described. The significance of the contractor's training was recognized and, on a characteristic example, an explanation of possible synchronization of still valid rules and new standards regarding the application of the protective measure - electrical separation was shown on a characteristic example. The boundaries of the contractor's responsibility regarding the correctness of electrical installations are clearly given. Finally, one way of running and connecting a temporary electrical installation is proposed in accordance with applicable laws, regulations and standards. |
topic |
low voltage electrical installations protection against electric shock construction installations |
url |
http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2017/0350-85281727057S.pdf |
work_keys_str_mv |
AT simicninoslav temporaryelectricalinstallationsbycontractorsinpowerplantsandindustry AT mrvicjovan temporaryelectricalinstallationsbycontractorsinpowerplantsandindustry AT jasikaranko temporaryelectricalinstallationsbycontractorsinpowerplantsandindustry |
_version_ |
1725313176119017472 |