Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors

Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when P...

Full description

Bibliographic Details
Main Authors: Fernando Álvarez Gómez, Ricardo Albarracín-Sánchez, Fernando Garnacho Vecino, Ricardo Granizo Arrabé
Format: Article
Language:English
Published: MDPI AG 2018-02-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/18/3/720
id doaj-d3309ef92e324698a9940b0039bcff63
record_format Article
spelling doaj-d3309ef92e324698a9940b0039bcff632020-11-25T01:05:58ZengMDPI AGSensors1424-82202018-02-0118372010.3390/s18030720s18030720Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and SensorsFernando Álvarez Gómez0Ricardo Albarracín-Sánchez1Fernando Garnacho Vecino2Ricardo Granizo Arrabé3Department of Electrical Engineering, Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, SpainDepartment of Electrical Engineering, Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, SpainDepartment of Electrical Engineering, Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, SpainDepartment of Electrical Engineering, Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, SpainPartial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when PD measurements are carried out on-site and on-line. For utilities, the most attractive characteristics of on-line measurements are that once the sensors are installed in the grid, the electrical service is uninterrupted and that electrical systems are tested in real operating conditions. In medium-voltage (MV) and HV installations, one of the critical points where an insulation defect can occur is inside metal-clad switchgears (including the cable terminals connected to them). Thus, this kind of equipment is increasingly being monitored to carry out proper maintenance based on their condition. This paper presents a study concerning the application of different electromagnetic measuring techniques (compliant with IEC 62478 and IEC 60270 standards), together with the use of suitable sensors, which enable the evaluation of the insulation condition mainly in MV switchgears. The main scope is to give a general overview about appropriate types of electromagnetic measuring methods and sensors to be applied, while considering the level of detail and accuracy in the diagnosis and the particular fail-save requirements of the electrical installations where the switchgears are located.http://www.mdpi.com/1424-8220/18/3/720partial dischargesinsulation diagnosisswitchgearsUHF antennasHF sensors
collection DOAJ
language English
format Article
sources DOAJ
author Fernando Álvarez Gómez
Ricardo Albarracín-Sánchez
Fernando Garnacho Vecino
Ricardo Granizo Arrabé
spellingShingle Fernando Álvarez Gómez
Ricardo Albarracín-Sánchez
Fernando Garnacho Vecino
Ricardo Granizo Arrabé
Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors
Sensors
partial discharges
insulation diagnosis
switchgears
UHF antennas
HF sensors
author_facet Fernando Álvarez Gómez
Ricardo Albarracín-Sánchez
Fernando Garnacho Vecino
Ricardo Granizo Arrabé
author_sort Fernando Álvarez Gómez
title Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors
title_short Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors
title_full Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors
title_fullStr Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors
title_full_unstemmed Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors
title_sort diagnosis of insulation condition of mv switchgears by application of different partial discharge measuring methods and sensors
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2018-02-01
description Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when PD measurements are carried out on-site and on-line. For utilities, the most attractive characteristics of on-line measurements are that once the sensors are installed in the grid, the electrical service is uninterrupted and that electrical systems are tested in real operating conditions. In medium-voltage (MV) and HV installations, one of the critical points where an insulation defect can occur is inside metal-clad switchgears (including the cable terminals connected to them). Thus, this kind of equipment is increasingly being monitored to carry out proper maintenance based on their condition. This paper presents a study concerning the application of different electromagnetic measuring techniques (compliant with IEC 62478 and IEC 60270 standards), together with the use of suitable sensors, which enable the evaluation of the insulation condition mainly in MV switchgears. The main scope is to give a general overview about appropriate types of electromagnetic measuring methods and sensors to be applied, while considering the level of detail and accuracy in the diagnosis and the particular fail-save requirements of the electrical installations where the switchgears are located.
topic partial discharges
insulation diagnosis
switchgears
UHF antennas
HF sensors
url http://www.mdpi.com/1424-8220/18/3/720
work_keys_str_mv AT fernandoalvarezgomez diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors
AT ricardoalbarracinsanchez diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors
AT fernandogarnachovecino diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors
AT ricardogranizoarrabe diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors
_version_ 1725192149222293504