Use of a Sampling Area-Adjusted Adenosine Triphosphate Bioluminescence Assay Based on Digital Image Quantification to Assess the Cleanliness of Hospital Surfaces

Contaminated surfaces play an important role in the transmission of pathogens. We sought to establish a criterion that could indicate “cleanliness” using a sampling area–adjusted adenosine triphosphate (ATP) assay. In the first phase of the study, target surfaces were selected for swab sampling befo...

Full description

Bibliographic Details
Main Authors: Yu-Huai Ho, Lih-Shinn Wang, Hui-Li Jiang, Chih-Hui Chang, Chia-Jung Hsieh, Dan-Chi Chang, Hsin-Yu Tu, Tan-Yun Chiu, Huei-Jen Chao, Chun-Chieh Tseng
Format: Article
Language:English
Published: MDPI AG 2016-06-01
Series:International Journal of Environmental Research and Public Health
Subjects:
Online Access:http://www.mdpi.com/1660-4601/13/6/576
Description
Summary:Contaminated surfaces play an important role in the transmission of pathogens. We sought to establish a criterion that could indicate “cleanliness” using a sampling area–adjusted adenosine triphosphate (ATP) assay. In the first phase of the study, target surfaces were selected for swab sampling before and after daily cleaning; then, an aerobic colony count (ACC) plate assay of bacteria and antibiotic-resistant bacteria was conducted. ATP swabs were also tested, and the ATP readings were reported as relative light units (RLUs). The results of the ACC and ATP assays were adjusted according to the sampling area. During the second phase of the study, a new cleaning process employing sodium dichloroisocyanurate (NaDCC) was implemented for comparison. Using the criterion of 2.5 colony-forming units (CFU)/cm2, 45% of the sampled sites were successfully cleaned during phase one of the study. During phase two, the pass rates of the surface samples (64%) were significantly improved, except under stringent (5 RLU/cm2) and lax (500 RLU) ATP criteria. Using receiver-operating characteristic curve analysis, the best cut-off point for an area-adjusted ATP level was 7.34 RLU/cm2, which corresponded to culture-assay levels of <2.5 CFU/cm2. An area adjustment of the ATP assay improved the degree of correlation with the ACC-assay results from weak to moderate.
ISSN:1660-4601