Implementation of real-time digital filter for the R wave detection

Quantification of the instantaneous heart rate is based on the detection of the R wave of the electrocardiographic signal. This process requires the implementation of strategies for real-time filtering for the time of occurrence of each R wave. Various mathematical techniques have been implemented f...

Full description

Bibliographic Details
Main Authors: Javier E. González-Barajas, Cristian Velandia-Cárdenas, Johann Nieto-Camacho
Format: Article
Language:English
Published: Instituto Tecnológico Metropolitano 2015-01-01
Series:TecnoLógicas
Subjects:
Online Access:http://itmojs.itm.edu.co/index.php/tecnologicas/article/view/659/654
id doaj-d48ceadd04bb4229941c48c9d26b391e
record_format Article
spelling doaj-d48ceadd04bb4229941c48c9d26b391e2020-11-25T01:46:35ZengInstituto Tecnológico MetropolitanoTecnoLógicas0123-77992256-53372015-01-011835758610.22430/22565337.217Implementation of real-time digital filter for the R wave detectionJavier E. González-Barajas0Cristian Velandia-Cárdenas1Johann Nieto-Camacho2 Universidad Santo Tomás Universidad Santo Tomás Universidad Santo TomásQuantification of the instantaneous heart rate is based on the detection of the R wave of the electrocardiographic signal. This process requires the implementation of strategies for real-time filtering for the time of occurrence of each R wave. Various mathematical techniques have been implemented for the detection of the R wave and these require digital systems with high performance computing. At present, there are opportunities to implement filtering strategies in low-cost devices in real time. The principal goal of this paper is to present the results obtained by implementing a real-time digital filter for the detection of the R wave of the ECG signal. The implemented strategy is based on the averaging and derived filters theory, which have been implemented on an ARM programmable device and open hardware. The filtering system provides a binary signal indicating the occurrence of the R wave and is input to a system for quantifying the instantaneous heart rate. The results in this paper are the basis for the implementation of a system for the quantification of heart rate in real time, which is presented the step of detecting R-wave.http://itmojs.itm.edu.co/index.php/tecnologicas/article/view/659/654R wavecomplex cardiacdigital filterreal timeaveraging
collection DOAJ
language English
format Article
sources DOAJ
author Javier E. González-Barajas
Cristian Velandia-Cárdenas
Johann Nieto-Camacho
spellingShingle Javier E. González-Barajas
Cristian Velandia-Cárdenas
Johann Nieto-Camacho
Implementation of real-time digital filter for the R wave detection
TecnoLógicas
R wave
complex cardiac
digital filter
real time
averaging
author_facet Javier E. González-Barajas
Cristian Velandia-Cárdenas
Johann Nieto-Camacho
author_sort Javier E. González-Barajas
title Implementation of real-time digital filter for the R wave detection
title_short Implementation of real-time digital filter for the R wave detection
title_full Implementation of real-time digital filter for the R wave detection
title_fullStr Implementation of real-time digital filter for the R wave detection
title_full_unstemmed Implementation of real-time digital filter for the R wave detection
title_sort implementation of real-time digital filter for the r wave detection
publisher Instituto Tecnológico Metropolitano
series TecnoLógicas
issn 0123-7799
2256-5337
publishDate 2015-01-01
description Quantification of the instantaneous heart rate is based on the detection of the R wave of the electrocardiographic signal. This process requires the implementation of strategies for real-time filtering for the time of occurrence of each R wave. Various mathematical techniques have been implemented for the detection of the R wave and these require digital systems with high performance computing. At present, there are opportunities to implement filtering strategies in low-cost devices in real time. The principal goal of this paper is to present the results obtained by implementing a real-time digital filter for the detection of the R wave of the ECG signal. The implemented strategy is based on the averaging and derived filters theory, which have been implemented on an ARM programmable device and open hardware. The filtering system provides a binary signal indicating the occurrence of the R wave and is input to a system for quantifying the instantaneous heart rate. The results in this paper are the basis for the implementation of a system for the quantification of heart rate in real time, which is presented the step of detecting R-wave.
topic R wave
complex cardiac
digital filter
real time
averaging
url http://itmojs.itm.edu.co/index.php/tecnologicas/article/view/659/654
work_keys_str_mv AT javieregonzalezbarajas implementationofrealtimedigitalfilterfortherwavedetection
AT cristianvelandiacardenas implementationofrealtimedigitalfilterfortherwavedetection
AT johannnietocamacho implementationofrealtimedigitalfilterfortherwavedetection
_version_ 1725018578788286464