Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite

Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospita...

Full description

Bibliographic Details
Main Authors: Zhao Y, Zhang Q, Meng Q, Wu F, Zhang L, Tang Y, Guan Y, An L
Format: Article
Language:English
Published: Dove Medical Press 2017-07-01
Series:International Journal of Nanomedicine
Subjects:
IgE
Online Access:https://www.dovepress.com/quantum-dots-based-lateral-flow-immunoassay-combined-with-image-analys-peer-reviewed-article-IJN
id doaj-d5ee6a2d07ba4aefb8592283fa3bf52f
record_format Article
spelling doaj-d5ee6a2d07ba4aefb8592283fa3bf52f2020-11-24T23:44:15ZengDove Medical PressInternational Journal of Nanomedicine1178-20132017-07-01Volume 124805481233582Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to miteZhao YZhang QMeng QWu FZhang LTang YGuan YAn LYan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospital, Qingdao University, Yantai, 3Department of Ophthalmology, The First Affiliated Hospital, Harbin Medical University, Harbin, 4Department of Burn and Plastic Surgery, The First Affiliated Hospital of Qinhuangdao, Qinhuangdao, People’s Republic of China *These authors contributed equally to this work Abstract: Semiquantitative and rapid detection of specific IgE (sIgE) with well clinical relevance to house dust mite (HDM) are promising for prevalence rhinitis and asthma patients due to the increasing air pollution. However, the conventional IgE measurement systems are time-consuming, complicated and require special instruments. Herein, we overcome the above limitations of sIgE to HDM detection system by developing a quantum dot nanobeads-based lateral flow immunoassay and an image analysis procedure. The proposed detection system could semiquantitatively measure the IgE in a linear range of 0.2–10 U/mL. Moreover, there is a well correlation between the developed detection system and the clinical symptoms by a comparison study using 56 positive patients’ sera and 40 healthy control sera. The proposed detection system is simple, robust and easy-to-use and promising for in home test. Keywords: lateral flow immunoassay, quantum dots, house dust mite, IgE https://www.dovepress.com/quantum-dots-based-lateral-flow-immunoassay-combined-with-image-analys-peer-reviewed-article-IJNLateral flow immunoassayQuantum dotsHouse dust miteIgE
collection DOAJ
language English
format Article
sources DOAJ
author Zhao Y
Zhang Q
Meng Q
Wu F
Zhang L
Tang Y
Guan Y
An L
spellingShingle Zhao Y
Zhang Q
Meng Q
Wu F
Zhang L
Tang Y
Guan Y
An L
Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite
International Journal of Nanomedicine
Lateral flow immunoassay
Quantum dots
House dust mite
IgE
author_facet Zhao Y
Zhang Q
Meng Q
Wu F
Zhang L
Tang Y
Guan Y
An L
author_sort Zhao Y
title Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite
title_short Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite
title_full Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite
title_fullStr Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite
title_full_unstemmed Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite
title_sort quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of ige antibody to mite
publisher Dove Medical Press
series International Journal of Nanomedicine
issn 1178-2013
publishDate 2017-07-01
description Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospital, Qingdao University, Yantai, 3Department of Ophthalmology, The First Affiliated Hospital, Harbin Medical University, Harbin, 4Department of Burn and Plastic Surgery, The First Affiliated Hospital of Qinhuangdao, Qinhuangdao, People’s Republic of China *These authors contributed equally to this work Abstract: Semiquantitative and rapid detection of specific IgE (sIgE) with well clinical relevance to house dust mite (HDM) are promising for prevalence rhinitis and asthma patients due to the increasing air pollution. However, the conventional IgE measurement systems are time-consuming, complicated and require special instruments. Herein, we overcome the above limitations of sIgE to HDM detection system by developing a quantum dot nanobeads-based lateral flow immunoassay and an image analysis procedure. The proposed detection system could semiquantitatively measure the IgE in a linear range of 0.2–10 U/mL. Moreover, there is a well correlation between the developed detection system and the clinical symptoms by a comparison study using 56 positive patients’ sera and 40 healthy control sera. The proposed detection system is simple, robust and easy-to-use and promising for in home test. Keywords: lateral flow immunoassay, quantum dots, house dust mite, IgE 
topic Lateral flow immunoassay
Quantum dots
House dust mite
IgE
url https://www.dovepress.com/quantum-dots-based-lateral-flow-immunoassay-combined-with-image-analys-peer-reviewed-article-IJN
work_keys_str_mv AT zhaoy quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
AT zhangq quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
AT mengq quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
AT wuf quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
AT zhangl quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
AT tangy quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
AT guany quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
AT anl quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite
_version_ 1725499347282427904