Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro

Background ― The treatment of the cancer, especially in more aggressive metastatic forms is more effective at early disease stage. However, existing diagnostic techniques are not sensitive enough for early cancer detection. An alternative, perspective diagnostic approach can be based on photoacousti...

Full description

Bibliographic Details
Main Authors: Yurii M. Ishbulatov, Viktoriia V. Skazkina, Anatoly S. Karavaev, Olga A. Inozemtseva, Daniil N. Bratashov, Arkady S. Abdurashitov, Oleg V. Grishin, Alexey N. Hramkov, Vladimir P. Zharov
Format: Article
Language:English
Published: Limited liability company «Science and Innovations» (Saratov) 2020-06-01
Series:Russian Open Medical Journal
Subjects:
Online Access:http://www.romj.org/node/314
id doaj-d7125f6c06db409fa96353481a6b1a1e
record_format Article
spelling doaj-d7125f6c06db409fa96353481a6b1a1e2021-10-06T12:15:49ZengLimited liability company «Science and Innovations» (Saratov)Russian Open Medical Journal2304-34152020-06-0192e020910.15275/rusomj.2020.0209Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitroYurii M. IshbulatovViktoriia V. SkazkinaAnatoly S. KaravaevOlga A. InozemtsevaDaniil N. BratashovArkady S. AbdurashitovOleg V. GrishinAlexey N. HramkovVladimir P. ZharovBackground ― The treatment of the cancer, especially in more aggressive metastatic forms is more effective at early disease stage. However, existing diagnostic techniques are not sensitive enough for early cancer detection. An alternative, perspective diagnostic approach can be based on photoacoustic (PA) method of irradiation of cancer cells in biotissue, blood and lymph by laser pulses. The fast thermal expansion of heated zones into cells associated with intrinsic or artificial PA contrast agents leads to generation of acoustic waves detected with ultrasound transducers. In particular, melanoma cells with melanin as a PA marker are darker than normal red blood cells and, therefore, produce greater acoustic responses. This technique can theoretically detect even a single cancer cell in the tissue and blood background; however, a robust algorithm of automated response detection is yet to be developed. Objective ― The main aim is to develop the approach for data pre-analysis that can improve the sensitivity and noise resistance of the automated in individual cancer cell detection algorithm, based on estimation of the amplitude of the acoustic responses. Methods ― Acoustic responses were obtained from a round polyurethane tube with human blood, or solution of the mouse melanoma cells in 10 mol/L concentration. In control experiments the laser was blocked by an opaque film. Many (up to 1000) acoustic responses were obtained from normal blood cells and pigmented cancer cells. Spectral analysis of the acoustic responses was used to find the spectral ranges that provide valuable diagnostic information with the sufficient signal-to-noise ratio. Results ― It was estimated that relevant diagnostics information in the acoustic responses is limited to the 0-12 MHz frequency band. Application of the 8th order low-pass Butterwort filter with 12 MHz cut-off frequency improved the signal-to-noise ratio from 21.14±10.39 to 110.81±56.94 for the cancer-related responses, and from 1.04±0.1 to 2.23±0.33 for the normal blood responses. Conclusions ― Adoption of low-pass filtering during the pre-analysis of acoustic responses results in better sensitivity of automated cancer cells detection algorithm.http://www.romj.org/node/314melanomaearly diagnosticsphotoacoustic flow cytometryspectral analysis
collection DOAJ
language English
format Article
sources DOAJ
author Yurii M. Ishbulatov
Viktoriia V. Skazkina
Anatoly S. Karavaev
Olga A. Inozemtseva
Daniil N. Bratashov
Arkady S. Abdurashitov
Oleg V. Grishin
Alexey N. Hramkov
Vladimir P. Zharov
spellingShingle Yurii M. Ishbulatov
Viktoriia V. Skazkina
Anatoly S. Karavaev
Olga A. Inozemtseva
Daniil N. Bratashov
Arkady S. Abdurashitov
Oleg V. Grishin
Alexey N. Hramkov
Vladimir P. Zharov
Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro
Russian Open Medical Journal
melanoma
early diagnostics
photoacoustic flow cytometry
spectral analysis
author_facet Yurii M. Ishbulatov
Viktoriia V. Skazkina
Anatoly S. Karavaev
Olga A. Inozemtseva
Daniil N. Bratashov
Arkady S. Abdurashitov
Oleg V. Grishin
Alexey N. Hramkov
Vladimir P. Zharov
author_sort Yurii M. Ishbulatov
title Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro
title_short Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro
title_full Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro
title_fullStr Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro
title_full_unstemmed Comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro
title_sort comparing the spectral properties of the laser-induced acoustic responses from blood and cancer cells in vitro
publisher Limited liability company «Science and Innovations» (Saratov)
series Russian Open Medical Journal
issn 2304-3415
publishDate 2020-06-01
description Background ― The treatment of the cancer, especially in more aggressive metastatic forms is more effective at early disease stage. However, existing diagnostic techniques are not sensitive enough for early cancer detection. An alternative, perspective diagnostic approach can be based on photoacoustic (PA) method of irradiation of cancer cells in biotissue, blood and lymph by laser pulses. The fast thermal expansion of heated zones into cells associated with intrinsic or artificial PA contrast agents leads to generation of acoustic waves detected with ultrasound transducers. In particular, melanoma cells with melanin as a PA marker are darker than normal red blood cells and, therefore, produce greater acoustic responses. This technique can theoretically detect even a single cancer cell in the tissue and blood background; however, a robust algorithm of automated response detection is yet to be developed. Objective ― The main aim is to develop the approach for data pre-analysis that can improve the sensitivity and noise resistance of the automated in individual cancer cell detection algorithm, based on estimation of the amplitude of the acoustic responses. Methods ― Acoustic responses were obtained from a round polyurethane tube with human blood, or solution of the mouse melanoma cells in 10 mol/L concentration. In control experiments the laser was blocked by an opaque film. Many (up to 1000) acoustic responses were obtained from normal blood cells and pigmented cancer cells. Spectral analysis of the acoustic responses was used to find the spectral ranges that provide valuable diagnostic information with the sufficient signal-to-noise ratio. Results ― It was estimated that relevant diagnostics information in the acoustic responses is limited to the 0-12 MHz frequency band. Application of the 8th order low-pass Butterwort filter with 12 MHz cut-off frequency improved the signal-to-noise ratio from 21.14±10.39 to 110.81±56.94 for the cancer-related responses, and from 1.04±0.1 to 2.23±0.33 for the normal blood responses. Conclusions ― Adoption of low-pass filtering during the pre-analysis of acoustic responses results in better sensitivity of automated cancer cells detection algorithm.
topic melanoma
early diagnostics
photoacoustic flow cytometry
spectral analysis
url http://www.romj.org/node/314
work_keys_str_mv AT yuriimishbulatov comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT viktoriiavskazkina comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT anatolyskaravaev comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT olgaainozemtseva comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT daniilnbratashov comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT arkadysabdurashitov comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT olegvgrishin comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT alexeynhramkov comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
AT vladimirpzharov comparingthespectralpropertiesofthelaserinducedacousticresponsesfrombloodandcancercellsinvitro
_version_ 1716840797328900096