The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs

The mathematical model of the steady flow distribution in the water supply system  containing a pipe network together with pump stations and regulatory reservoirs has been presented. This mathematical model allows  to guarantee  the possibility of the parallel engagement of any number of  pumping st...

Full description

Bibliographic Details
Main Authors: Сергей Васильевич Дядюн, Ольга Николаевна Штельма
Format: Article
Language:English
Published: PC Technology Center 2014-02-01
Series:Tehnologìčnij Audit ta Rezervi Virobnictva
Subjects:
Online Access:http://journals.uran.ua/tarp/article/view/21690
id doaj-d7d8912132944a7ea0580f9186a6977c
record_format Article
spelling doaj-d7d8912132944a7ea0580f9186a6977c2020-11-25T02:02:28ZengPC Technology CenterTehnologìčnij Audit ta Rezervi Virobnictva2226-37802312-83722014-02-0114(15)161810.15587/2312-8372.2014.2169021690The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirsСергей Васильевич Дядюн0Ольга Николаевна Штельма1O.M. Beketov National University of Urban Economy in Kharkiv, 12, Revolution St., Kharkov, Ukraine, 61 002O.M. Beketov National University of Urban Economy in Kharkiv, 12, Revolution St., Kharkov, Ukraine, 61 002The mathematical model of the steady flow distribution in the water supply system  containing a pipe network together with pump stations and regulatory reservoirs has been presented. This mathematical model allows  to guarantee  the possibility of the parallel engagement of any number of  pumping stations aggregates without the need for prior equivalenting their characteristics. The mathematical model of steady flow distribution in the water supply system, containing pumping stations and regulatory reservoirs has been  used to analyze the quality of its operation under the implementation of the  control actions at the pumping stations, solving the problem of evaluating the effectiveness of operational planning modes of water supply systems  operation throughout the examined time interval, as well as to control the  correctness of taken decisions on the management of the technological processes of  water supply and water distribution.  The method of imitational modeling of real functioning water supply systems has been used to carry out the research.http://journals.uran.ua/tarp/article/view/21690mathematical modelingmodelwater supply systemssteady flow distributionpump stationregulatory reservoirs
collection DOAJ
language English
format Article
sources DOAJ
author Сергей Васильевич Дядюн
Ольга Николаевна Штельма
spellingShingle Сергей Васильевич Дядюн
Ольга Николаевна Штельма
The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs
Tehnologìčnij Audit ta Rezervi Virobnictva
mathematical modeling
model
water supply systems
steady flow distribution
pump station
regulatory reservoirs
author_facet Сергей Васильевич Дядюн
Ольга Николаевна Штельма
author_sort Сергей Васильевич Дядюн
title The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs
title_short The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs
title_full The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs
title_fullStr The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs
title_full_unstemmed The mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs
title_sort mathematical modelling of water supply systems contaiing a pipe network, pump stations and regulatory reservoirs
publisher PC Technology Center
series Tehnologìčnij Audit ta Rezervi Virobnictva
issn 2226-3780
2312-8372
publishDate 2014-02-01
description The mathematical model of the steady flow distribution in the water supply system  containing a pipe network together with pump stations and regulatory reservoirs has been presented. This mathematical model allows  to guarantee  the possibility of the parallel engagement of any number of  pumping stations aggregates without the need for prior equivalenting their characteristics. The mathematical model of steady flow distribution in the water supply system, containing pumping stations and regulatory reservoirs has been  used to analyze the quality of its operation under the implementation of the  control actions at the pumping stations, solving the problem of evaluating the effectiveness of operational planning modes of water supply systems  operation throughout the examined time interval, as well as to control the  correctness of taken decisions on the management of the technological processes of  water supply and water distribution.  The method of imitational modeling of real functioning water supply systems has been used to carry out the research.
topic mathematical modeling
model
water supply systems
steady flow distribution
pump station
regulatory reservoirs
url http://journals.uran.ua/tarp/article/view/21690
work_keys_str_mv AT sergejvasilʹevičdâdûn themathematicalmodellingofwatersupplysystemscontaiingapipenetworkpumpstationsandregulatoryreservoirs
AT olʹganikolaevnaštelʹma themathematicalmodellingofwatersupplysystemscontaiingapipenetworkpumpstationsandregulatoryreservoirs
AT sergejvasilʹevičdâdûn mathematicalmodellingofwatersupplysystemscontaiingapipenetworkpumpstationsandregulatoryreservoirs
AT olʹganikolaevnaštelʹma mathematicalmodellingofwatersupplysystemscontaiingapipenetworkpumpstationsandregulatoryreservoirs
_version_ 1724952714922688512