Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients

Abstract This work aimed to investigate the effect of different shim techniques, voxel sizes, and repetition time (TR) on using theT2 and T2* sequences to determine their optimum settings to investigate the quantification of iron in transfused dependent sickle cell patients. The effect of each of th...

Full description

Bibliographic Details
Main Authors: Azza Ahmed, Amani Baldo, A. Sulieman, Hind Mirghani, Fouad A. Abolaban, I. I. Suliman, Isam Salih
Format: Article
Language:English
Published: Nature Publishing Group 2021-04-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-021-88116-8
id doaj-d8249cc277474e8ea0ad63c55d14c7a6
record_format Article
spelling doaj-d8249cc277474e8ea0ad63c55d14c7a62021-04-25T11:33:10ZengNature Publishing GroupScientific Reports2045-23222021-04-0111111010.1038/s41598-021-88116-8Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patientsAzza Ahmed0Amani Baldo1A. Sulieman2Hind Mirghani3Fouad A. Abolaban4I. I. Suliman5Isam Salih6Sudan Atomic Energy CommissionJaffar Bin Auf Paediatric HospitalRadiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz UniversityJaffar Bin Auf Paediatric HospitalNuclear Engineering Department, Faculty of Engineering, King Abdulaziz UniversitySudan Atomic Energy CommissionSudan Atomic Energy CommissionAbstract This work aimed to investigate the effect of different shim techniques, voxel sizes, and repetition time (TR) on using theT2 and T2* sequences to determine their optimum settings to investigate the quantification of iron in transfused dependent sickle cell patients. The effect of each of these parameters was investigated on phantoms of different Gadolinium (Gd) concentrations, on 10 volunteers and 25 patients using a1 5T MRI Philips scanner. No significant difference between the three shim techniques was noticed in either T2 or T2* sequence measurements. Pixel sizes of 1 × 1 and 2 × 2 mm provided optimum results for T2 measurements. At 1 × 1 mm pixel size the T2* measurements experienced less error in measurements than the size of 2.5 × 2.5 mm used in the literature. Even though the slice thickness variation did not provide any changes in T2 measurements, the 12 mm provided optimum T2* measurements. TR variation did not yield significant changes on either T2 or T2* measurements. These results indicate that both T2 and T2* sequences can be further improved by providing more reliable measurements and reducing acquisition time.https://doi.org/10.1038/s41598-021-88116-8
collection DOAJ
language English
format Article
sources DOAJ
author Azza Ahmed
Amani Baldo
A. Sulieman
Hind Mirghani
Fouad A. Abolaban
I. I. Suliman
Isam Salih
spellingShingle Azza Ahmed
Amani Baldo
A. Sulieman
Hind Mirghani
Fouad A. Abolaban
I. I. Suliman
Isam Salih
Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients
Scientific Reports
author_facet Azza Ahmed
Amani Baldo
A. Sulieman
Hind Mirghani
Fouad A. Abolaban
I. I. Suliman
Isam Salih
author_sort Azza Ahmed
title Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients
title_short Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients
title_full Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients
title_fullStr Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients
title_full_unstemmed Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients
title_sort optimisation of t2 and t2* sequences in mri for better quantification of iron on transfused dependent sickle cell patients
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2021-04-01
description Abstract This work aimed to investigate the effect of different shim techniques, voxel sizes, and repetition time (TR) on using theT2 and T2* sequences to determine their optimum settings to investigate the quantification of iron in transfused dependent sickle cell patients. The effect of each of these parameters was investigated on phantoms of different Gadolinium (Gd) concentrations, on 10 volunteers and 25 patients using a1 5T MRI Philips scanner. No significant difference between the three shim techniques was noticed in either T2 or T2* sequence measurements. Pixel sizes of 1 × 1 and 2 × 2 mm provided optimum results for T2 measurements. At 1 × 1 mm pixel size the T2* measurements experienced less error in measurements than the size of 2.5 × 2.5 mm used in the literature. Even though the slice thickness variation did not provide any changes in T2 measurements, the 12 mm provided optimum T2* measurements. TR variation did not yield significant changes on either T2 or T2* measurements. These results indicate that both T2 and T2* sequences can be further improved by providing more reliable measurements and reducing acquisition time.
url https://doi.org/10.1038/s41598-021-88116-8
work_keys_str_mv AT azzaahmed optimisationoft2andt2sequencesinmriforbetterquantificationofironontransfuseddependentsicklecellpatients
AT amanibaldo optimisationoft2andt2sequencesinmriforbetterquantificationofironontransfuseddependentsicklecellpatients
AT asulieman optimisationoft2andt2sequencesinmriforbetterquantificationofironontransfuseddependentsicklecellpatients
AT hindmirghani optimisationoft2andt2sequencesinmriforbetterquantificationofironontransfuseddependentsicklecellpatients
AT fouadaabolaban optimisationoft2andt2sequencesinmriforbetterquantificationofironontransfuseddependentsicklecellpatients
AT iisuliman optimisationoft2andt2sequencesinmriforbetterquantificationofironontransfuseddependentsicklecellpatients
AT isamsalih optimisationoft2andt2sequencesinmriforbetterquantificationofironontransfuseddependentsicklecellpatients
_version_ 1721509618316738560