Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated Spectroradiometer

The international standard IEC62670-3 (International Electrotechnical Committee) “Photovoltaic Concentrators (CPV) Performance Testing—Part 3—Performance Measurements and Power Rating” sets the guidelines for power measurements of a CPV device, both in indoor and outdoor conditions. When measuring i...

Full description

Bibliographic Details
Main Authors: Diego Pavanello, Roberto Galleano, Robert P. Kenny
Format: Article
Language:English
Published: MDPI AG 2018-01-01
Series:Applied Sciences
Subjects:
Online Access:http://www.mdpi.com/2076-3417/8/2/186
id doaj-d94486bdc741437db4fa2b930417fb29
record_format Article
spelling doaj-d94486bdc741437db4fa2b930417fb292020-11-24T21:44:29ZengMDPI AGApplied Sciences2076-34172018-01-018218610.3390/app8020186app8020186Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated SpectroradiometerDiego Pavanello0Roberto Galleano1Robert P. Kenny2Directorate C—Energy, Transport and Climate, European Commission Joint Research Centre, I-21027 Ispra, ItalyDirectorate C—Energy, Transport and Climate, European Commission Joint Research Centre, I-21027 Ispra, ItalyDirectorate C—Energy, Transport and Climate, European Commission Joint Research Centre, I-21027 Ispra, ItalyThe international standard IEC62670-3 (International Electrotechnical Committee) “Photovoltaic Concentrators (CPV) Performance Testing—Part 3—Performance Measurements and Power Rating” sets the guidelines for power measurements of a CPV device, both in indoor and outdoor conditions. When measuring in outdoor conditions, the acquired data have to be filtered a posteriori, in order to select only those points measured with ambient conditions close to the Concentrator Standard Operating Conditions (CSOC). The most stringent requirement to be met is related to the three Spectral Matching Ratios (SMR), which have all to be within the limit of 1.00 ± 0.03. SMR are usually determined by the ratio of the currents of component cells to monitor the outdoor spectral ratio conditions during the CPV device power measurements. Experience demonstrates that obtaining real world data meeting these strict conditions is very difficult in practice. However, increasing the acceptable range would make the entire filtering process less appropriate from a physical point of view. Given the importance of correctly measuring the SMR, an estimation of their associated measurement uncertainties is needed to allow a proper assessment of the validity of the 3% limit. In this study a Monte Carlo simulation has been used, to allow the estimation of the propagation of uncertainties in expressions having the and integral form. The method consists of applying both random and wavelength correlated errors to the measured spectra and to the measured spectral responses of the three CPV cell junctions, according to the measurement uncertainties of the European Solar Test Installation (ESTI). The experimental data used in this study have been acquired during clear sky conditions in May 2016, at ESTI’s facilities in Ispra, northern Italy (45°49′ N 8°37′ E).http://www.mdpi.com/2076-3417/8/2/186concentrator photovoltaicsmeasurement uncertaintyInternational standardsMonte Carlo simulation
collection DOAJ
language English
format Article
sources DOAJ
author Diego Pavanello
Roberto Galleano
Robert P. Kenny
spellingShingle Diego Pavanello
Roberto Galleano
Robert P. Kenny
Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated Spectroradiometer
Applied Sciences
concentrator photovoltaics
measurement uncertainty
International standards
Monte Carlo simulation
author_facet Diego Pavanello
Roberto Galleano
Robert P. Kenny
author_sort Diego Pavanello
title Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated Spectroradiometer
title_short Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated Spectroradiometer
title_full Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated Spectroradiometer
title_fullStr Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated Spectroradiometer
title_full_unstemmed Uncertainty Propagation of Spectral Matching Ratios Measured Using a Calibrated Spectroradiometer
title_sort uncertainty propagation of spectral matching ratios measured using a calibrated spectroradiometer
publisher MDPI AG
series Applied Sciences
issn 2076-3417
publishDate 2018-01-01
description The international standard IEC62670-3 (International Electrotechnical Committee) “Photovoltaic Concentrators (CPV) Performance Testing—Part 3—Performance Measurements and Power Rating” sets the guidelines for power measurements of a CPV device, both in indoor and outdoor conditions. When measuring in outdoor conditions, the acquired data have to be filtered a posteriori, in order to select only those points measured with ambient conditions close to the Concentrator Standard Operating Conditions (CSOC). The most stringent requirement to be met is related to the three Spectral Matching Ratios (SMR), which have all to be within the limit of 1.00 ± 0.03. SMR are usually determined by the ratio of the currents of component cells to monitor the outdoor spectral ratio conditions during the CPV device power measurements. Experience demonstrates that obtaining real world data meeting these strict conditions is very difficult in practice. However, increasing the acceptable range would make the entire filtering process less appropriate from a physical point of view. Given the importance of correctly measuring the SMR, an estimation of their associated measurement uncertainties is needed to allow a proper assessment of the validity of the 3% limit. In this study a Monte Carlo simulation has been used, to allow the estimation of the propagation of uncertainties in expressions having the and integral form. The method consists of applying both random and wavelength correlated errors to the measured spectra and to the measured spectral responses of the three CPV cell junctions, according to the measurement uncertainties of the European Solar Test Installation (ESTI). The experimental data used in this study have been acquired during clear sky conditions in May 2016, at ESTI’s facilities in Ispra, northern Italy (45°49′ N 8°37′ E).
topic concentrator photovoltaics
measurement uncertainty
International standards
Monte Carlo simulation
url http://www.mdpi.com/2076-3417/8/2/186
work_keys_str_mv AT diegopavanello uncertaintypropagationofspectralmatchingratiosmeasuredusingacalibratedspectroradiometer
AT robertogalleano uncertaintypropagationofspectralmatchingratiosmeasuredusingacalibratedspectroradiometer
AT robertpkenny uncertaintypropagationofspectralmatchingratiosmeasuredusingacalibratedspectroradiometer
_version_ 1725909840561176576