Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion

The Council for Scientific and Industrial Research (CSIR) conducts research into the effect of underwater explosions on maritime structures and equipment. One of the parameters that are required to be measured to a large degree of accuracy is the shock wave velocity in close proximity (10 - 120 char...

Full description

Bibliographic Details
Main Authors: A. Roux, G.N. Nurick
Format: Article
Language:English
Published: Academy of Science of South Africa 2010-01-01
Series:South African Journal of Science
Online Access:http://192.168.0.118/index.php/sajs/article/view/10053
id doaj-d9ebfaeb290c40bc9bbdb389c2b2e91d
record_format Article
spelling doaj-d9ebfaeb290c40bc9bbdb389c2b2e91d2021-04-04T20:06:32ZengAcademy of Science of South AfricaSouth African Journal of Science1996-74892010-01-011059/10Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosionA. Roux0G.N. Nurick1Council for Scientific and Industrial Research, 5 John Costas Street, Plankenbrug, Stellenbosch 7600, South Africa.Blast Impact and Survivability Research Unit, Department of Mechanical Engineering, University of Cape TownThe Council for Scientific and Industrial Research (CSIR) conducts research into the effect of underwater explosions on maritime structures and equipment. One of the parameters that are required to be measured to a large degree of accuracy is the shock wave velocity in close proximity (10 - 120 charge radii) of the explosion, without having to revert to the streak photography method. This distance is in the region where the near field crosses over to the far field, and it would be expected that the distance - time curve would not be linear. The streak photography method produces accuracy in the very near field of the explosion, but is not recommended for accurate measurements at distances beyond 20 charge radii. We investigated the response of an optical sensor constructed to measure the light flash of an underwater blast to determine the moment of explosion. By measurement of the time taken between this moment and the time when the shock wave reaches the pressure sensors, accurate measurements of the distance - time history (and hence shock wave velocity) could be calculated. Twelve general purpose phototransistors were used in a parallel configuration to enhance the sensitivity of the sensor. These transistors were connected directly to a conditioning amplifier which formed the interface between the transistors and the data acquisition equipment. The results that were obtained confirmed that the light intensity of the flash of the explosion increased to a maximum within several microseconds. Measurements of the average velocity of the shock wave propagation, based on the flash measurement as a marker, correlated to within 0.1%, meaning that this method of marking the moment of explosion to within several microseconds had been successful. This method can therefore be used in similar underwater blast measurement applications when a measurement marker of the moment of explosion is required.http://192.168.0.118/index.php/sajs/article/view/10053
collection DOAJ
language English
format Article
sources DOAJ
author A. Roux
G.N. Nurick
spellingShingle A. Roux
G.N. Nurick
Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion
South African Journal of Science
author_facet A. Roux
G.N. Nurick
author_sort A. Roux
title Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion
title_short Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion
title_full Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion
title_fullStr Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion
title_full_unstemmed Experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion
title_sort experimental response of an optical sensor used to determine the moment of blast by sensing the flash of the explosion
publisher Academy of Science of South Africa
series South African Journal of Science
issn 1996-7489
publishDate 2010-01-01
description The Council for Scientific and Industrial Research (CSIR) conducts research into the effect of underwater explosions on maritime structures and equipment. One of the parameters that are required to be measured to a large degree of accuracy is the shock wave velocity in close proximity (10 - 120 charge radii) of the explosion, without having to revert to the streak photography method. This distance is in the region where the near field crosses over to the far field, and it would be expected that the distance - time curve would not be linear. The streak photography method produces accuracy in the very near field of the explosion, but is not recommended for accurate measurements at distances beyond 20 charge radii. We investigated the response of an optical sensor constructed to measure the light flash of an underwater blast to determine the moment of explosion. By measurement of the time taken between this moment and the time when the shock wave reaches the pressure sensors, accurate measurements of the distance - time history (and hence shock wave velocity) could be calculated. Twelve general purpose phototransistors were used in a parallel configuration to enhance the sensitivity of the sensor. These transistors were connected directly to a conditioning amplifier which formed the interface between the transistors and the data acquisition equipment. The results that were obtained confirmed that the light intensity of the flash of the explosion increased to a maximum within several microseconds. Measurements of the average velocity of the shock wave propagation, based on the flash measurement as a marker, correlated to within 0.1%, meaning that this method of marking the moment of explosion to within several microseconds had been successful. This method can therefore be used in similar underwater blast measurement applications when a measurement marker of the moment of explosion is required.
url http://192.168.0.118/index.php/sajs/article/view/10053
work_keys_str_mv AT aroux experimentalresponseofanopticalsensorusedtodeterminethemomentofblastbysensingtheflashoftheexplosion
AT gnnurick experimentalresponseofanopticalsensorusedtodeterminethemomentofblastbysensingtheflashoftheexplosion
_version_ 1724164130082914304