Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation

A delta-connected STATCOM with cascade multilevel full H-bridge (FHB) converter has been applied for phase balancing and power factor correction of unbalanced load in a three-phase, three-wire power distribution system. In this paper, a feedforward compensation formula is presented for the STATCOM b...

Full description

Bibliographic Details
Main Authors: Wei-Neng Chang, Ching-Huan Liao
Format: Article
Language:English
Published: MDPI AG 2017-07-01
Series:Energies
Subjects:
FHB
Online Access:https://www.mdpi.com/1996-1073/10/7/921
id doaj-da4deeae49e543b5b796858e63ede394
record_format Article
spelling doaj-da4deeae49e543b5b796858e63ede3942020-11-24T22:37:33ZengMDPI AGEnergies1996-10732017-07-0110792110.3390/en10070921en10070921Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load CompensationWei-Neng Chang0Ching-Huan Liao1Department of Electrical Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan Dist., 333 Tao-Yuan City, TaiwanNational Chung-Shan Institute of Science and Technology, 486, 6th Neighborhood, Sec. Jia’an, Zhongzheng Road, Longtan Dist., 325 Tao-Yuan City, TaiwanA delta-connected STATCOM with cascade multilevel full H-bridge (FHB) converter has been applied for phase balancing and power factor correction of unbalanced load in a three-phase, three-wire power distribution system. In this paper, a feedforward compensation formula is presented for the STATCOM by using the symmetrical components method to compensate unbalanced load. Computer simulation is performed for preliminary verification. Accordingly, a hardware prototype employing a TMS320F2812 DSP-based system is built for final verification test. Experimental results show that the proposed STATCOM is very effective for real-time unbalanced load compensation.https://www.mdpi.com/1996-1073/10/7/921FHBhardware testload compensationSTATCOMsymmetrical components method
collection DOAJ
language English
format Article
sources DOAJ
author Wei-Neng Chang
Ching-Huan Liao
spellingShingle Wei-Neng Chang
Ching-Huan Liao
Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation
Energies
FHB
hardware test
load compensation
STATCOM
symmetrical components method
author_facet Wei-Neng Chang
Ching-Huan Liao
author_sort Wei-Neng Chang
title Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation
title_short Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation
title_full Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation
title_fullStr Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation
title_full_unstemmed Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation
title_sort design and implementation of a statcom based on a multilevel fhb converter with delta-connected configuration for unbalanced load compensation
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2017-07-01
description A delta-connected STATCOM with cascade multilevel full H-bridge (FHB) converter has been applied for phase balancing and power factor correction of unbalanced load in a three-phase, three-wire power distribution system. In this paper, a feedforward compensation formula is presented for the STATCOM by using the symmetrical components method to compensate unbalanced load. Computer simulation is performed for preliminary verification. Accordingly, a hardware prototype employing a TMS320F2812 DSP-based system is built for final verification test. Experimental results show that the proposed STATCOM is very effective for real-time unbalanced load compensation.
topic FHB
hardware test
load compensation
STATCOM
symmetrical components method
url https://www.mdpi.com/1996-1073/10/7/921
work_keys_str_mv AT weinengchang designandimplementationofastatcombasedonamultilevelfhbconverterwithdeltaconnectedconfigurationforunbalancedloadcompensation
AT chinghuanliao designandimplementationofastatcombasedonamultilevelfhbconverterwithdeltaconnectedconfigurationforunbalancedloadcompensation
_version_ 1725716612776984576