Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface

Coastal aquifers and the deeper subsurface are increasingly exploited. The accompanying perforation of the subsurface for those purposes has increased the risk of short-circuiting of originally separated aquifers. This study shows how this short-circuiting negatively impacts the freshwater recovery...

Full description

Bibliographic Details
Main Authors: K. G. Zuurbier, P. J. Stuyfzand
Format: Article
Language:English
Published: Copernicus Publications 2017-02-01
Series:Hydrology and Earth System Sciences
Online Access:http://www.hydrol-earth-syst-sci.net/21/1173/2017/hess-21-1173-2017.pdf
id doaj-da6a0416a4fd4fc0bceee7c1190811f4
record_format Article
spelling doaj-da6a0416a4fd4fc0bceee7c1190811f42020-11-24T23:05:09ZengCopernicus PublicationsHydrology and Earth System Sciences1027-56061607-79382017-02-012121173118810.5194/hess-21-1173-2017Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurfaceK. G. Zuurbier0P. J. Stuyfzand1KWR Watercycle Research Institute, Groningenhaven 7, 3433 PE Nieuwegein, the NetherlandsKWR Watercycle Research Institute, Groningenhaven 7, 3433 PE Nieuwegein, the NetherlandsCoastal aquifers and the deeper subsurface are increasingly exploited. The accompanying perforation of the subsurface for those purposes has increased the risk of short-circuiting of originally separated aquifers. This study shows how this short-circuiting negatively impacts the freshwater recovery efficiency (RE) during aquifer storage and recovery (ASR) in coastal aquifers. ASR was applied in a shallow saltwater aquifer overlying a deeper, confined saltwater aquifer, which was targeted for seasonal aquifer thermal energy storage (ATES). Although both aquifers were considered properly separated (i.e., a continuous clay layer prevented rapid groundwater flow between both aquifers), intrusion of deeper saltwater into the shallower aquifer quickly terminated the freshwater recovery. The presumable pathway was a nearby ATES borehole. This finding was supported by field measurements, hydrochemical analyses, and variable-density solute transport modeling (SEAWAT version 4; Langevin et al., 2007). The potentially rapid short-circuiting during storage and recovery can reduce the RE of ASR to null. When limited mixing with ambient groundwater is allowed, a linear RE decrease by short-circuiting with increasing distance from the ASR well within the radius of the injected ASR bubble was observed. Interception of deep short-circuiting water can mitigate the observed RE decrease, although complete compensation of the RE decrease will generally be unattainable. Brackish water upconing from the underlying aquitard towards the shallow recovery wells of the ASR system with multiple partially penetrating wells (MPPW-ASR) was observed. This <q>leakage</q> may lead to a lower recovery efficiency than based on current ASR performance estimations.http://www.hydrol-earth-syst-sci.net/21/1173/2017/hess-21-1173-2017.pdf
collection DOAJ
language English
format Article
sources DOAJ
author K. G. Zuurbier
P. J. Stuyfzand
spellingShingle K. G. Zuurbier
P. J. Stuyfzand
Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface
Hydrology and Earth System Sciences
author_facet K. G. Zuurbier
P. J. Stuyfzand
author_sort K. G. Zuurbier
title Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface
title_short Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface
title_full Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface
title_fullStr Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface
title_full_unstemmed Consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface
title_sort consequences and mitigation of saltwater intrusion induced by short-circuiting during aquifer storage and recovery in a coastal subsurface
publisher Copernicus Publications
series Hydrology and Earth System Sciences
issn 1027-5606
1607-7938
publishDate 2017-02-01
description Coastal aquifers and the deeper subsurface are increasingly exploited. The accompanying perforation of the subsurface for those purposes has increased the risk of short-circuiting of originally separated aquifers. This study shows how this short-circuiting negatively impacts the freshwater recovery efficiency (RE) during aquifer storage and recovery (ASR) in coastal aquifers. ASR was applied in a shallow saltwater aquifer overlying a deeper, confined saltwater aquifer, which was targeted for seasonal aquifer thermal energy storage (ATES). Although both aquifers were considered properly separated (i.e., a continuous clay layer prevented rapid groundwater flow between both aquifers), intrusion of deeper saltwater into the shallower aquifer quickly terminated the freshwater recovery. The presumable pathway was a nearby ATES borehole. This finding was supported by field measurements, hydrochemical analyses, and variable-density solute transport modeling (SEAWAT version 4; Langevin et al., 2007). The potentially rapid short-circuiting during storage and recovery can reduce the RE of ASR to null. When limited mixing with ambient groundwater is allowed, a linear RE decrease by short-circuiting with increasing distance from the ASR well within the radius of the injected ASR bubble was observed. Interception of deep short-circuiting water can mitigate the observed RE decrease, although complete compensation of the RE decrease will generally be unattainable. Brackish water upconing from the underlying aquitard towards the shallow recovery wells of the ASR system with multiple partially penetrating wells (MPPW-ASR) was observed. This <q>leakage</q> may lead to a lower recovery efficiency than based on current ASR performance estimations.
url http://www.hydrol-earth-syst-sci.net/21/1173/2017/hess-21-1173-2017.pdf
work_keys_str_mv AT kgzuurbier consequencesandmitigationofsaltwaterintrusioninducedbyshortcircuitingduringaquiferstorageandrecoveryinacoastalsubsurface
AT pjstuyfzand consequencesandmitigationofsaltwaterintrusioninducedbyshortcircuitingduringaquiferstorageandrecoveryinacoastalsubsurface
_version_ 1725627254146334720