PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters
A new type of PLL-less Direct Power Control with robust implementation and deadbeat response is presented for grid-tie inverters. In this work a novel positive sequence detector is also implemented which ensures the elimination of perturbation at the output current due to harmonics content. The cont...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Spanish |
Published: |
Universitat Politecnica de Valencia
2015-04-01
|
Series: | Revista Iberoamericana de Automática e Informática Industrial RIAI |
Subjects: | |
Online Access: | https://polipapers.upv.es/index.php/RIAI/article/view/9393 |
id |
doaj-db52ebbd8ccf4f70b5fa53c47c8b56ff |
---|---|
record_format |
Article |
spelling |
doaj-db52ebbd8ccf4f70b5fa53c47c8b56ff2021-02-02T06:43:32ZspaUniversitat Politecnica de ValenciaRevista Iberoamericana de Automática e Informática Industrial RIAI1697-79121697-79202015-04-0112219920710.1016/j.riai.2015.02.0046428PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase InvertersJ.R. Fischer0S.A. González1I. Carugati2M.G. Judewicz3D.O. Carrica4Universidad Nacional de Mar del PlataUniversidad Nacional de Mar del PlataUniversidad Nacional de Mar del PlataUniversidad Nacional de Mar del PlataUniversidad Nacional de Mar del PlataA new type of PLL-less Direct Power Control with robust implementation and deadbeat response is presented for grid-tie inverters. In this work a novel positive sequence detector is also implemented which ensures the elimination of perturbation at the output current due to harmonics content. The control algorithm has an intrinsic synchronization scheme which avoids an additional three-phase PLL. This maximizes the response time and power tracking achieving precise power step reference change in less than 200 μs. The results obtained are shown with both simulations and experiential results in a 15kW three-phase inverter that verifies the performance of the proposed controller, yielding low-harmonics output currents even in abnormal operating situations.https://polipapers.upv.es/index.php/RIAI/article/view/9393Control Directo de PotenciaControl de Corriente Predictivo RobustoInversor de Tensión Controlado en CorrienteDistorsión Armónica |
collection |
DOAJ |
language |
Spanish |
format |
Article |
sources |
DOAJ |
author |
J.R. Fischer S.A. González I. Carugati M.G. Judewicz D.O. Carrica |
spellingShingle |
J.R. Fischer S.A. González I. Carugati M.G. Judewicz D.O. Carrica PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters Revista Iberoamericana de Automática e Informática Industrial RIAI Control Directo de Potencia Control de Corriente Predictivo Robusto Inversor de Tensión Controlado en Corriente Distorsión Armónica |
author_facet |
J.R. Fischer S.A. González I. Carugati M.G. Judewicz D.O. Carrica |
author_sort |
J.R. Fischer |
title |
PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters |
title_short |
PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters |
title_full |
PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters |
title_fullStr |
PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters |
title_full_unstemmed |
PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters |
title_sort |
pll-less robust deadbeat-response direct power control of grid-tie three-phase inverters |
publisher |
Universitat Politecnica de Valencia |
series |
Revista Iberoamericana de Automática e Informática Industrial RIAI |
issn |
1697-7912 1697-7920 |
publishDate |
2015-04-01 |
description |
A new type of PLL-less Direct Power Control with robust implementation and deadbeat response is presented for grid-tie inverters. In this work a novel positive sequence detector is also implemented which ensures the elimination of perturbation at the output current due to harmonics content. The control algorithm has an intrinsic synchronization scheme which avoids an additional three-phase PLL. This maximizes the response time and power tracking achieving precise power step reference change in less than 200 μs. The results obtained are shown with both simulations and experiential results in a 15kW three-phase inverter that verifies the performance of the proposed controller, yielding low-harmonics output currents even in abnormal operating situations. |
topic |
Control Directo de Potencia Control de Corriente Predictivo Robusto Inversor de Tensión Controlado en Corriente Distorsión Armónica |
url |
https://polipapers.upv.es/index.php/RIAI/article/view/9393 |
work_keys_str_mv |
AT jrfischer plllessrobustdeadbeatresponsedirectpowercontrolofgridtiethreephaseinverters AT sagonzalez plllessrobustdeadbeatresponsedirectpowercontrolofgridtiethreephaseinverters AT icarugati plllessrobustdeadbeatresponsedirectpowercontrolofgridtiethreephaseinverters AT mgjudewicz plllessrobustdeadbeatresponsedirectpowercontrolofgridtiethreephaseinverters AT docarrica plllessrobustdeadbeatresponsedirectpowercontrolofgridtiethreephaseinverters |
_version_ |
1724300812232949760 |