Study on malachite green residue detection system
In this work, a malachite green residue detection system for aquaculture monitoring was established. The system includes a new method based on DNA adapter body of malachite green sensor, a handheld electrochemical detector, and the combination of the two, which constitute a set of high performance,...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://doi.org/10.1051/matecconf/201818907003 |
id |
doaj-dca46a06c43546b3bc826118e84a2fb6 |
---|---|
record_format |
Article |
spelling |
doaj-dca46a06c43546b3bc826118e84a2fb62021-04-02T10:00:53ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011890700310.1051/matecconf/201818907003matecconf_meamt2018_07003Study on malachite green residue detection systemShen TongZhou TongWan YingSu YanIn this work, a malachite green residue detection system for aquaculture monitoring was established. The system includes a new method based on DNA adapter body of malachite green sensor, a handheld electrochemical detector, and the combination of the two, which constitute a set of high performance, convenient and portable malachite green residue detection system. According to the experimental results, the detection of this system is range from 1.0 x 10-3ng . ml-1 to 10ng . mi-1. Hence, the detection system proposed in this paper can meet the accuracy convenience and quick detection of malachite green residue in aquatic products water.https://doi.org/10.1051/matecconf/201818907003 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Shen Tong Zhou Tong Wan Ying Su Yan |
spellingShingle |
Shen Tong Zhou Tong Wan Ying Su Yan Study on malachite green residue detection system MATEC Web of Conferences |
author_facet |
Shen Tong Zhou Tong Wan Ying Su Yan |
author_sort |
Shen Tong |
title |
Study on malachite green residue detection system |
title_short |
Study on malachite green residue detection system |
title_full |
Study on malachite green residue detection system |
title_fullStr |
Study on malachite green residue detection system |
title_full_unstemmed |
Study on malachite green residue detection system |
title_sort |
study on malachite green residue detection system |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2018-01-01 |
description |
In this work, a malachite green residue detection system for aquaculture monitoring was established. The system includes a new method based on DNA adapter body of malachite green sensor, a handheld electrochemical detector, and the combination of the two, which constitute a set of high performance, convenient and portable malachite green residue detection system. According to the experimental results, the detection of this system is range from 1.0 x 10-3ng . ml-1 to 10ng . mi-1. Hence, the detection system proposed in this paper can meet the accuracy convenience and quick detection of malachite green residue in aquatic products water. |
url |
https://doi.org/10.1051/matecconf/201818907003 |
work_keys_str_mv |
AT shentong studyonmalachitegreenresiduedetectionsystem AT zhoutong studyonmalachitegreenresiduedetectionsystem AT wanying studyonmalachitegreenresiduedetectionsystem AT suyan studyonmalachitegreenresiduedetectionsystem |
_version_ |
1724168129048739840 |