Study on malachite green residue detection system

In this work, a malachite green residue detection system for aquaculture monitoring was established. The system includes a new method based on DNA adapter body of malachite green sensor, a handheld electrochemical detector, and the combination of the two, which constitute a set of high performance,...

Full description

Bibliographic Details
Main Authors: Shen Tong, Zhou Tong, Wan Ying, Su Yan
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201818907003
id doaj-dca46a06c43546b3bc826118e84a2fb6
record_format Article
spelling doaj-dca46a06c43546b3bc826118e84a2fb62021-04-02T10:00:53ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011890700310.1051/matecconf/201818907003matecconf_meamt2018_07003Study on malachite green residue detection systemShen TongZhou TongWan YingSu YanIn this work, a malachite green residue detection system for aquaculture monitoring was established. The system includes a new method based on DNA adapter body of malachite green sensor, a handheld electrochemical detector, and the combination of the two, which constitute a set of high performance, convenient and portable malachite green residue detection system. According to the experimental results, the detection of this system is range from 1.0 x 10-3ng . ml-1 to 10ng . mi-1. Hence, the detection system proposed in this paper can meet the accuracy convenience and quick detection of malachite green residue in aquatic products water.https://doi.org/10.1051/matecconf/201818907003
collection DOAJ
language English
format Article
sources DOAJ
author Shen Tong
Zhou Tong
Wan Ying
Su Yan
spellingShingle Shen Tong
Zhou Tong
Wan Ying
Su Yan
Study on malachite green residue detection system
MATEC Web of Conferences
author_facet Shen Tong
Zhou Tong
Wan Ying
Su Yan
author_sort Shen Tong
title Study on malachite green residue detection system
title_short Study on malachite green residue detection system
title_full Study on malachite green residue detection system
title_fullStr Study on malachite green residue detection system
title_full_unstemmed Study on malachite green residue detection system
title_sort study on malachite green residue detection system
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2018-01-01
description In this work, a malachite green residue detection system for aquaculture monitoring was established. The system includes a new method based on DNA adapter body of malachite green sensor, a handheld electrochemical detector, and the combination of the two, which constitute a set of high performance, convenient and portable malachite green residue detection system. According to the experimental results, the detection of this system is range from 1.0 x 10-3ng . ml-1 to 10ng . mi-1. Hence, the detection system proposed in this paper can meet the accuracy convenience and quick detection of malachite green residue in aquatic products water.
url https://doi.org/10.1051/matecconf/201818907003
work_keys_str_mv AT shentong studyonmalachitegreenresiduedetectionsystem
AT zhoutong studyonmalachitegreenresiduedetectionsystem
AT wanying studyonmalachitegreenresiduedetectionsystem
AT suyan studyonmalachitegreenresiduedetectionsystem
_version_ 1724168129048739840