FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITY

The finite-element calculation of the static stress-strain state of the middle ear was made in this paper. The malleus, incus and stapes models were constructed on the basis of tomographic data. The tympanic membrane model was obtained using the equations of elliptic hyperboloids. The tympanic membr...

Full description

Bibliographic Details
Main Authors: Gennadi I. Mikhasev, Sergei M. Bosiakov, Lyudmila G. Petrova, Marina M. Maisyuk
Format: Article
Language:English
Published: University of Niš 2015-12-01
Series:Facta Universitatis. Series: Mechanical Engineering
Online Access:http://casopisi.junis.ni.ac.rs/index.php/FUMechEng/article/view/942
id doaj-de0e8ab64d1247e1ac989ccff77e769b
record_format Article
spelling doaj-de0e8ab64d1247e1ac989ccff77e769b2020-11-25T04:03:23ZengUniversity of NišFacta Universitatis. Series: Mechanical Engineering0354-20252335-01642015-12-01133249257599FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITYGennadi I. Mikhasev0Sergei M. Bosiakov1Lyudmila G. Petrova2Marina M. Maisyuk3Belarussian State UniversityBelarussian State UniversityNationalL Centre of OtorhinolaryngologyNationalL Centre of OtorhinolaryngologyThe finite-element calculation of the static stress-strain state of the middle ear was made in this paper. The malleus, incus and stapes models were constructed on the basis of tomographic data. The tympanic membrane model was obtained using the equations of elliptic hyperboloids. The tympanic membrane consists of the pars tensa and pars flaccida, which have different thicknesses and elasticity moduli. Absolute deformations of the tympanic membrane were defined at different values of negative pressure in the tympanic cavity. The critical values of elastic modulus for the pars tensa posterosuperior quadrant were found for the point at which the tympanic membrane touches the auditory ossicles. Obtained results can be used to predict the thickness of a cartilaginous graft which is overlaid on the posterosuperior quadrant of the pars tensa in order to eliminate the retraction pocket.http://casopisi.junis.ni.ac.rs/index.php/FUMechEng/article/view/942
collection DOAJ
language English
format Article
sources DOAJ
author Gennadi I. Mikhasev
Sergei M. Bosiakov
Lyudmila G. Petrova
Marina M. Maisyuk
spellingShingle Gennadi I. Mikhasev
Sergei M. Bosiakov
Lyudmila G. Petrova
Marina M. Maisyuk
FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITY
Facta Universitatis. Series: Mechanical Engineering
author_facet Gennadi I. Mikhasev
Sergei M. Bosiakov
Lyudmila G. Petrova
Marina M. Maisyuk
author_sort Gennadi I. Mikhasev
title FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITY
title_short FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITY
title_full FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITY
title_fullStr FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITY
title_full_unstemmed FINITE-ELEMENT MODELLING OF THE TYMPANIC MEMBRANE RETRACTION POCKET UNDER NEGATIVE PRESSURE IN THE TYMPANIC CAVITY
title_sort finite-element modelling of the tympanic membrane retraction pocket under negative pressure in the tympanic cavity
publisher University of Niš
series Facta Universitatis. Series: Mechanical Engineering
issn 0354-2025
2335-0164
publishDate 2015-12-01
description The finite-element calculation of the static stress-strain state of the middle ear was made in this paper. The malleus, incus and stapes models were constructed on the basis of tomographic data. The tympanic membrane model was obtained using the equations of elliptic hyperboloids. The tympanic membrane consists of the pars tensa and pars flaccida, which have different thicknesses and elasticity moduli. Absolute deformations of the tympanic membrane were defined at different values of negative pressure in the tympanic cavity. The critical values of elastic modulus for the pars tensa posterosuperior quadrant were found for the point at which the tympanic membrane touches the auditory ossicles. Obtained results can be used to predict the thickness of a cartilaginous graft which is overlaid on the posterosuperior quadrant of the pars tensa in order to eliminate the retraction pocket.
url http://casopisi.junis.ni.ac.rs/index.php/FUMechEng/article/view/942
work_keys_str_mv AT gennadiimikhasev finiteelementmodellingofthetympanicmembraneretractionpocketundernegativepressureinthetympaniccavity
AT sergeimbosiakov finiteelementmodellingofthetympanicmembraneretractionpocketundernegativepressureinthetympaniccavity
AT lyudmilagpetrova finiteelementmodellingofthetympanicmembraneretractionpocketundernegativepressureinthetympaniccavity
AT marinammaisyuk finiteelementmodellingofthetympanicmembraneretractionpocketundernegativepressureinthetympaniccavity
_version_ 1724440385696038912