The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function

Purpose: To evaluate the alteration of lower lid configuration and function with anterior transposition surgery of the inferior oblique (IO) muscle. Patients and Methods: A prospective clinical trial was conducted on a consecutive series of patients underwent anterior transposition of the IO as a so...

Full description

Bibliographic Details
Main Authors: Tugba Goncu, Sevim Cakmak, Ali Akal, Halit Oguz
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2016;volume=64;issue=1;spage=33;epage=37;aulast=Goncu
id doaj-e02fc34456af42dd9cc18bf3a3570bdb
record_format Article
spelling doaj-e02fc34456af42dd9cc18bf3a3570bdb2020-11-24T23:57:22ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892016-01-01641333710.4103/0301-4738.178138The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and functionTugba GoncuSevim CakmakAli AkalHalit OguzPurpose: To evaluate the alteration of lower lid configuration and function with anterior transposition surgery of the inferior oblique (IO) muscle. Patients and Methods: A prospective clinical trial was conducted on a consecutive series of patients underwent anterior transposition of the IO as a sole operation. All patients received a thorough ophthalmic examination 1 day before and 3 months after surgery. Output parameters were consisted of palpebral fissure, margin reflex distance 1–2, lower lid function, hertel value, and lower lid crease. The differences of the collected data were calculated for statistical significance by using the Wilcoxon test. Results: A total of 19 eyes of 16 consecutive patients were included. The median preoperative grade of IO overaction was 3.5 (ranging from 3 to 4), which decreased to 0 (ranging from 0 to 2) postoperatively (P < 0.05). No significant change was observed in all parameters 3 months postoperatively (P > 0.05). Conclusion: In this study, no significant effect on lower lid configuration and function was observed following IO anterior transposition in which the disinserted muscle was placed posterior to inferior rectus insertion.http://www.ijo.in/article.asp?issn=0301-4738;year=2016;volume=64;issue=1;spage=33;epage=37;aulast=GoncuInferior eyelid functioninferior oblique anterior transpositionlower lid creasepalpebral fissure
collection DOAJ
language English
format Article
sources DOAJ
author Tugba Goncu
Sevim Cakmak
Ali Akal
Halit Oguz
spellingShingle Tugba Goncu
Sevim Cakmak
Ali Akal
Halit Oguz
The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function
Indian Journal of Ophthalmology
Inferior eyelid function
inferior oblique anterior transposition
lower lid crease
palpebral fissure
author_facet Tugba Goncu
Sevim Cakmak
Ali Akal
Halit Oguz
author_sort Tugba Goncu
title The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function
title_short The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function
title_full The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function
title_fullStr The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function
title_full_unstemmed The effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function
title_sort effect of anterior transposition of the inferior oblique muscle on eyelid configuration and function
publisher Wolters Kluwer Medknow Publications
series Indian Journal of Ophthalmology
issn 0301-4738
1998-3689
publishDate 2016-01-01
description Purpose: To evaluate the alteration of lower lid configuration and function with anterior transposition surgery of the inferior oblique (IO) muscle. Patients and Methods: A prospective clinical trial was conducted on a consecutive series of patients underwent anterior transposition of the IO as a sole operation. All patients received a thorough ophthalmic examination 1 day before and 3 months after surgery. Output parameters were consisted of palpebral fissure, margin reflex distance 1–2, lower lid function, hertel value, and lower lid crease. The differences of the collected data were calculated for statistical significance by using the Wilcoxon test. Results: A total of 19 eyes of 16 consecutive patients were included. The median preoperative grade of IO overaction was 3.5 (ranging from 3 to 4), which decreased to 0 (ranging from 0 to 2) postoperatively (P < 0.05). No significant change was observed in all parameters 3 months postoperatively (P > 0.05). Conclusion: In this study, no significant effect on lower lid configuration and function was observed following IO anterior transposition in which the disinserted muscle was placed posterior to inferior rectus insertion.
topic Inferior eyelid function
inferior oblique anterior transposition
lower lid crease
palpebral fissure
url http://www.ijo.in/article.asp?issn=0301-4738;year=2016;volume=64;issue=1;spage=33;epage=37;aulast=Goncu
work_keys_str_mv AT tugbagoncu theeffectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
AT sevimcakmak theeffectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
AT aliakal theeffectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
AT halitoguz theeffectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
AT tugbagoncu effectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
AT sevimcakmak effectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
AT aliakal effectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
AT halitoguz effectofanteriortranspositionoftheinferiorobliquemuscleoneyelidconfigurationandfunction
_version_ 1725454343633633280