Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

<strong><em>Introduction:</em></strong> Geometric distortion, an important parameter in neurology and oncology<strong>.</strong> The current study aimed to design and construct a new three<strong>-</strong>dimensional (3D) phantom using a 3D printer in...

Full description

Bibliographic Details
Main Authors: sadegh shurche, Mohammad Yousefi sooteh
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2019-09-01
Series:Iranian Journal of Medical Physics
Subjects:
MRI
Online Access:http://ijmp.mums.ac.ir/article_12037_d2c3ad88d4cbf3cebb2a7bb5886d4e03.pdf
id doaj-e1082ec3461b4c52a9807fdb8733f774
record_format Article
spelling doaj-e1082ec3461b4c52a9807fdb8733f7742020-11-25T00:51:29ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722345-36722019-09-0116537738410.22038/ijmp.2018.35346.144212037Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging Systemsadegh shurche0Mohammad Yousefi sooteh1Physics and medical engineering Department, Medical Faculty, Tehran University of Medical Sciences, Tehran, IranDepartment of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran<strong><em>Introduction:</em></strong> Geometric distortion, an important parameter in neurology and oncology<strong>.</strong> The current study aimed to design and construct a new three<strong>-</strong>dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. <strong><em>Material and Methods:</em></strong> In this study, a new phantom containing 13,824 reference features (control points) was designed with AutoCAD software, fabricated with a 3D printer, and filled with vegetable oil. This phantom was tested on the Siemens 3 Tesla Prisma MRI model using a 64-channel head coil. Six-slice computed tomography (CT) scan images were used as a reference. Moreover, the reference features of MRI images were matched with those of CT scan images using a 3D reference model. The reproducibility of the phantom was investigated on three different days (three different imaging sessions per day). <strong><em>Results:</em></strong> The obtained 3D results indicated that the non-uniformity of field and nonlinearity of the gradients and imaging reproducibility could lead to geometric distortion. The mean Euclidean distance error for MRI volume was less than 1 mm. The maximum Euclidean error was 1.5 mm. Distortion in the whole volume was pronounced more specifically at the edges of the magnetic field. <strong><em>Conclusion: </em></strong>The results showed that the amount of distortion in the middle of the field was less than at its sides. This phantom can be used to check the distortion filters on the device. Furthermore, this phantom can be used to study geometric distortion in scenarios that require a small study volume, such as prostate studies.http://ijmp.mums.ac.ir/article_12037_d2c3ad88d4cbf3cebb2a7bb5886d4e03.pdfMRIDistortionPhantom
collection DOAJ
language English
format Article
sources DOAJ
author sadegh shurche
Mohammad Yousefi sooteh
spellingShingle sadegh shurche
Mohammad Yousefi sooteh
Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Iranian Journal of Medical Physics
MRI
Distortion
Phantom
author_facet sadegh shurche
Mohammad Yousefi sooteh
author_sort sadegh shurche
title Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
title_short Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
title_full Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
title_fullStr Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
title_full_unstemmed Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
title_sort fabrication of new 3d phantom for the measurement of geometric distortion in magnetic resonance imaging system
publisher Mashhad University of Medical Sciences
series Iranian Journal of Medical Physics
issn 2345-3672
2345-3672
publishDate 2019-09-01
description <strong><em>Introduction:</em></strong> Geometric distortion, an important parameter in neurology and oncology<strong>.</strong> The current study aimed to design and construct a new three<strong>-</strong>dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. <strong><em>Material and Methods:</em></strong> In this study, a new phantom containing 13,824 reference features (control points) was designed with AutoCAD software, fabricated with a 3D printer, and filled with vegetable oil. This phantom was tested on the Siemens 3 Tesla Prisma MRI model using a 64-channel head coil. Six-slice computed tomography (CT) scan images were used as a reference. Moreover, the reference features of MRI images were matched with those of CT scan images using a 3D reference model. The reproducibility of the phantom was investigated on three different days (three different imaging sessions per day). <strong><em>Results:</em></strong> The obtained 3D results indicated that the non-uniformity of field and nonlinearity of the gradients and imaging reproducibility could lead to geometric distortion. The mean Euclidean distance error for MRI volume was less than 1 mm. The maximum Euclidean error was 1.5 mm. Distortion in the whole volume was pronounced more specifically at the edges of the magnetic field. <strong><em>Conclusion: </em></strong>The results showed that the amount of distortion in the middle of the field was less than at its sides. This phantom can be used to check the distortion filters on the device. Furthermore, this phantom can be used to study geometric distortion in scenarios that require a small study volume, such as prostate studies.
topic MRI
Distortion
Phantom
url http://ijmp.mums.ac.ir/article_12037_d2c3ad88d4cbf3cebb2a7bb5886d4e03.pdf
work_keys_str_mv AT sadeghshurche fabricationofnew3dphantomforthemeasurementofgeometricdistortioninmagneticresonanceimagingsystem
AT mohammadyousefisooteh fabricationofnew3dphantomforthemeasurementofgeometricdistortioninmagneticresonanceimagingsystem
_version_ 1725245568294322176