Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage Sags

<b> </b>This<b> </b>paper presents the preliminary results of our research activity aimed at forecasting the number of voltage sags in distribution networks. The final goal of the research is to develop proper algorithms that the network operators could use to forecast how ma...

Full description

Bibliographic Details
Main Authors: Michele De Santis, Leonardo Di Stasio, Christian Noce, Paola Verde, Pietro Varilone
Format: Article
Language:English
Published: MDPI AG 2021-02-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/5/1264
id doaj-e25c711aa17246f0bbc8f857fabbc625
record_format Article
spelling doaj-e25c711aa17246f0bbc8f857fabbc6252021-02-26T00:04:23ZengMDPI AGEnergies1996-10732021-02-01141264126410.3390/en14051264Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage SagsMichele De Santis0Leonardo Di Stasio1Christian Noce2Paola Verde3Pietro Varilone4Department of Ingegneria, Università Niccolò Cusano di Roma, 00166 Roma, ItalyDepartment of Ingegneria elettrica e dell’informazione “Maurizio Scarano”, Università di Cassino e dell-informazione, 03043 Cassino, ItalyE-distribuzione S.p.A., 00198 Roma, ItalyDepartment of Ingegneria elettrica e dell’informazione “Maurizio Scarano”, Università di Cassino e dell-informazione, 03043 Cassino, ItalyDepartment of Ingegneria elettrica e dell’informazione “Maurizio Scarano”, Università di Cassino e dell-informazione, 03043 Cassino, Italy<b> </b>This<b> </b>paper presents the preliminary results of our research activity aimed at forecasting the number of voltage sags in distribution networks. The final goal of the research is to develop proper algorithms that the network operators could use to forecast how many voltage sags will occur at a given site. The availability of four years of measurements at Italian Medium Voltage (MV) networks allowed the statistical analyses of the sample voltage sags without performing model-based simulations of the electric systems in short-circuit conditions. The challenge we faced was to overcome the barrier of the extremely long measurement times that are considered mandatory to obtain a forecast with adequate confidence. The method we have presented uses the random variable <i>time to next event</i> to characterize the statistics of the voltage sags instead of the variable <i>number of sags</i>, which usually is expressed on an annual basis. The choice of this variable allows the use of a large data set, even if only a few years of measurements are available. The statistical characterization of the measured voltage sags by the variable<i> time to next event</i> requires preliminary data-conditioning steps, since the voltage sags that are measured can be divided in two main categories, i.e., rare voltage sags and clusters of voltage sags. Only the rare voltage sags meet the conditions of a Poisson process, and they can be used to forecast the performance that can be expected in the future. However, the clusters do not have the characteristics of memoryless events because they are sequential, time-dependent phenomena the occurrences of which are due to exogenic factors, such as rain, lightning strikes, wind, and other adverse weather conditions. In this paper, we show that filtering the clusters out from all the measured sags is crucial for making successful forecast. In addition, we show that a filter, equal for all of the nodes of the system, represents the origin of the most important critical aspects in the successive steps of the forecasting method. In the paper, we also provide a means of tracking the main problems that are encountered. The initial results encouraged the future development of new efficient techniques of filtering on a site-by-site basis to eliminate the clusters.https://www.mdpi.com/1996-1073/14/5/1264power qualityforecasting methodvoltage sags
collection DOAJ
language English
format Article
sources DOAJ
author Michele De Santis
Leonardo Di Stasio
Christian Noce
Paola Verde
Pietro Varilone
spellingShingle Michele De Santis
Leonardo Di Stasio
Christian Noce
Paola Verde
Pietro Varilone
Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage Sags
Energies
power quality
forecasting method
voltage sags
author_facet Michele De Santis
Leonardo Di Stasio
Christian Noce
Paola Verde
Pietro Varilone
author_sort Michele De Santis
title Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage Sags
title_short Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage Sags
title_full Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage Sags
title_fullStr Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage Sags
title_full_unstemmed Initial Results of an Extensive, Long-term Study of the Forecasting of Voltage Sags
title_sort initial results of an extensive, long-term study of the forecasting of voltage sags
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2021-02-01
description <b> </b>This<b> </b>paper presents the preliminary results of our research activity aimed at forecasting the number of voltage sags in distribution networks. The final goal of the research is to develop proper algorithms that the network operators could use to forecast how many voltage sags will occur at a given site. The availability of four years of measurements at Italian Medium Voltage (MV) networks allowed the statistical analyses of the sample voltage sags without performing model-based simulations of the electric systems in short-circuit conditions. The challenge we faced was to overcome the barrier of the extremely long measurement times that are considered mandatory to obtain a forecast with adequate confidence. The method we have presented uses the random variable <i>time to next event</i> to characterize the statistics of the voltage sags instead of the variable <i>number of sags</i>, which usually is expressed on an annual basis. The choice of this variable allows the use of a large data set, even if only a few years of measurements are available. The statistical characterization of the measured voltage sags by the variable<i> time to next event</i> requires preliminary data-conditioning steps, since the voltage sags that are measured can be divided in two main categories, i.e., rare voltage sags and clusters of voltage sags. Only the rare voltage sags meet the conditions of a Poisson process, and they can be used to forecast the performance that can be expected in the future. However, the clusters do not have the characteristics of memoryless events because they are sequential, time-dependent phenomena the occurrences of which are due to exogenic factors, such as rain, lightning strikes, wind, and other adverse weather conditions. In this paper, we show that filtering the clusters out from all the measured sags is crucial for making successful forecast. In addition, we show that a filter, equal for all of the nodes of the system, represents the origin of the most important critical aspects in the successive steps of the forecasting method. In the paper, we also provide a means of tracking the main problems that are encountered. The initial results encouraged the future development of new efficient techniques of filtering on a site-by-site basis to eliminate the clusters.
topic power quality
forecasting method
voltage sags
url https://www.mdpi.com/1996-1073/14/5/1264
work_keys_str_mv AT micheledesantis initialresultsofanextensivelongtermstudyoftheforecastingofvoltagesags
AT leonardodistasio initialresultsofanextensivelongtermstudyoftheforecastingofvoltagesags
AT christiannoce initialresultsofanextensivelongtermstudyoftheforecastingofvoltagesags
AT paolaverde initialresultsofanextensivelongtermstudyoftheforecastingofvoltagesags
AT pietrovarilone initialresultsofanextensivelongtermstudyoftheforecastingofvoltagesags
_version_ 1724250423937728512