A Quality Control Assay to Access the HCl Molarity of Radionuclide Solutions
Strontium-82 is produced by proton activation of a rubidium chloride target in an accelerator or cyclotron and purified by ion exchange chromatography. The Strontrium-82 is used in Cardigen generators to produce Rubidium-82 for cardiac imaging. Quality control testing of the purified Strontium-82 is...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2016-05-01
|
Series: | Chemosensors |
Subjects: | |
Online Access: | http://www.mdpi.com/2227-9040/4/2/9 |
id |
doaj-e26ab9ed7c3b45a2a15cac9886868fc2 |
---|---|
record_format |
Article |
spelling |
doaj-e26ab9ed7c3b45a2a15cac9886868fc22020-11-24T22:51:21ZengMDPI AGChemosensors2227-90402016-05-0142910.3390/chemosensors4020009chemosensors4020009A Quality Control Assay to Access the HCl Molarity of Radionuclide SolutionsJonathan Fitzsimmons0Collider Accelerator Department, Brookhaven National Laboratory, Upton, NY 11973, USAStrontium-82 is produced by proton activation of a rubidium chloride target in an accelerator or cyclotron and purified by ion exchange chromatography. The Strontrium-82 is used in Cardigen generators to produce Rubidium-82 for cardiac imaging. Quality control testing of the purified Strontium-82 is performed with Inductively Coupled Plasma-Optical Emission spectroscopy (ICP-OES) and gamma spectroscopy. To meet Department of Energy specifications for HCl molarity the purified Strontium-82 solution needs to be tested to determine if the isotope is in the 0.05–0.5 M HCl range. This manuscript reports a simple HCl molarity test to determine if the purified Strontium-82 solution meets specifications. Validation of the assay was performed by evaluating all solutions associate with Strontium-82 processing.http://www.mdpi.com/2227-9040/4/2/9molarity testquality controlstrontium-82Sr-82BromoCresol Purple |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jonathan Fitzsimmons |
spellingShingle |
Jonathan Fitzsimmons A Quality Control Assay to Access the HCl Molarity of Radionuclide Solutions Chemosensors molarity test quality control strontium-82 Sr-82 BromoCresol Purple |
author_facet |
Jonathan Fitzsimmons |
author_sort |
Jonathan Fitzsimmons |
title |
A Quality Control Assay to Access the HCl Molarity of Radionuclide Solutions |
title_short |
A Quality Control Assay to Access the HCl Molarity of Radionuclide Solutions |
title_full |
A Quality Control Assay to Access the HCl Molarity of Radionuclide Solutions |
title_fullStr |
A Quality Control Assay to Access the HCl Molarity of Radionuclide Solutions |
title_full_unstemmed |
A Quality Control Assay to Access the HCl Molarity of Radionuclide Solutions |
title_sort |
quality control assay to access the hcl molarity of radionuclide solutions |
publisher |
MDPI AG |
series |
Chemosensors |
issn |
2227-9040 |
publishDate |
2016-05-01 |
description |
Strontium-82 is produced by proton activation of a rubidium chloride target in an accelerator or cyclotron and purified by ion exchange chromatography. The Strontrium-82 is used in Cardigen generators to produce Rubidium-82 for cardiac imaging. Quality control testing of the purified Strontium-82 is performed with Inductively Coupled Plasma-Optical Emission spectroscopy (ICP-OES) and gamma spectroscopy. To meet Department of Energy specifications for HCl molarity the purified Strontium-82 solution needs to be tested to determine if the isotope is in the 0.05–0.5 M HCl range. This manuscript reports a simple HCl molarity test to determine if the purified Strontium-82 solution meets specifications. Validation of the assay was performed by evaluating all solutions associate with Strontium-82 processing. |
topic |
molarity test quality control strontium-82 Sr-82 BromoCresol Purple |
url |
http://www.mdpi.com/2227-9040/4/2/9 |
work_keys_str_mv |
AT jonathanfitzsimmons aqualitycontrolassaytoaccessthehclmolarityofradionuclidesolutions AT jonathanfitzsimmons qualitycontrolassaytoaccessthehclmolarityofradionuclidesolutions |
_version_ |
1725670171677294592 |