Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems

INTRODUCCIÓN: el objetivo fue determinar ex vivo la adaptación marginal y ajuste interno en estructuras de zirconiaytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab®. MÉTODOS: se tomaron 15 pilares protésicos prefabricados contorneados de implantes divididos en tres grupos. Se fabric...

Full description

Bibliographic Details
Main Authors: Carlos Bernardo Caparroso Pérez, Diana Virginia Marín Muñoz, Alejandro Echavarría Velásquez
Format: Article
Language:English
Published: Universidad de Antioquia 2011-06-01
Series:Revista Facultad de Odontología Universidad de Antioquia
Subjects:
Online Access:http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0121-246X2011000100006
id doaj-e39840c55d6e43e9af3a50e1b71ccdd7
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Carlos Bernardo Caparroso Pérez
Diana Virginia Marín Muñoz
Alejandro Echavarría Velásquez
spellingShingle Carlos Bernardo Caparroso Pérez
Diana Virginia Marín Muñoz
Alejandro Echavarría Velásquez
Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems
Revista Facultad de Odontología Universidad de Antioquia
zirconia-ytria Procera
zirconia ytria Cerec in-Lab
CAD/CAM
adaptación marginal
ajuste interno
zirconia-ytria Procera
zirconia ytria Cerec in-Lab
CAD/CAM
marginal adaptation
internal adjustment
author_facet Carlos Bernardo Caparroso Pérez
Diana Virginia Marín Muñoz
Alejandro Echavarría Velásquez
author_sort Carlos Bernardo Caparroso Pérez
title Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems
title_short Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems
title_full Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems
title_fullStr Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems
title_full_unstemmed Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems
title_sort adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas cad/cam procera® y cerec in-lab® marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with procera® and cerec in-lab® cad/cam systems
publisher Universidad de Antioquia
series Revista Facultad de Odontología Universidad de Antioquia
issn 0121-246X
2145-7670
publishDate 2011-06-01
description INTRODUCCIÓN: el objetivo fue determinar ex vivo la adaptación marginal y ajuste interno en estructuras de zirconiaytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab®. MÉTODOS: se tomaron 15 pilares protésicos prefabricados contorneados de implantes divididos en tres grupos. Se fabricaron estructuras en aleación noble Pd-Au (control), Procera All Zircon® y Cerec In-lab YZ cubes®. Para evaluar la adaptación marginal se tomaron ocho medidas en la circunferencia del pilar protésico, tomando la distancia entre el borde de la estructura y el pilar. Para determinar el ajuste interno se hicieron ocho medidas desde la superficie externa del pilar a la superficie interna de la restauración. Las mediciones fueron hechas por microscopia óptica (50X). Los datos obtenidos fueron analizados por medio del análisis de varianza de una vía, la t de Student y prueba de Dunnett. RESULTADOS: el promedio de adaptación marginal del grupo control fue 18,24 &micro;m &plusmn;4,81; el grupo Procera® 21,62 &micro;m &plusmn;12,15 y el grupo Cerec In-lab® de 47,34 &micro;m &plusmn;17,72. El promedio de ajuste interno para las estructuras Pd-Au fue 34,60 &micro;m &plusmn;16,16; Procera® 118,67 &micro;m &plusmn;50,84 y el Cerec In-lab® 65,62 &micro;m &plusmn;25,80. CONCLUSIONES: los valores de adaptación marginal de las estructuras de aleación metálica y de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab® están entre los valores clínicamente aceptables. Las medidas de ajuste interno obtenidos para los grupos aleación metálica y Cerec® se encuentran dentro del rango reportado en la literatura. Mientras que el promedio obtenido para el grupo Procera® 118,67 &micro;m &plusmn;50,84, aunque se acercó al límite máximo de ajuste interno reportado en la literatura, no se evidenció diferencia estadísticamente significativa con el sistema Cerec In-lab®.<br>INTRODUCTION: the purpose of this in vitro study was to determine the marginal adaptation and internal fit in zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems. METHODS: fifteen prefabricated implant abutments were divided in three equally sized groups; noble metal alloy Pd-Au structures were then fabricated (control group), Procera® and Cerec In-lab YZ cubes® (n = 5). The marginal gap was determined by measuring 8 points around the abutment circumference taking the distance between the margin of the structure and the abutment. In order to determine internal fit, 8 measures were taken from the abutment&sbquo;s external surface to the internal surface of the restoration. The measures were done with an optical microscope (50X). The data was the statistically analyzed using 1-way ANOVA, Student&sbquo;s paired t test and Dunnett&sbquo;test. RESULTS: marginal adaptation mean for the control group was 18.24&plusmn;4.81&micro;m and Procera® 21.62 &micro;m &plusmn;12.15 &micro;m, while the average for Cerec In-lab® was 47.34 &micro;m &plusmn;17.72 &micro;m. The internal fit for the control group was 34,60 &micro;m &plusmn;16.16 &micro;m and Procera® group was of 118.67 &micro;m &plusmn;50.84 &micro;m in average and Cerec In-lab® 65.62 &micro;m &plusmn;25.80 &micro;m. CONCLUSION: the metal alloy and zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems showed clinically acceptable marginal gap values. The internal fit values for metal alloy and Cerec® frameworks are within the ranges reported in the literature. While the mean for the Procera® group was 118.67 &micro;m &plusmn;50.84, which is close to the internal fit maximum limit reported in the literature, there was no statistically significant difference when compared with the Cerec-In-lab® system.
topic zirconia-ytria Procera
zirconia ytria Cerec in-Lab
CAD/CAM
adaptación marginal
ajuste interno
zirconia-ytria Procera
zirconia ytria Cerec in-Lab
CAD/CAM
marginal adaptation
internal adjustment
url http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0121-246X2011000100006
work_keys_str_mv AT carlosbernardocaparrosoperez adaptacionmarginalyajusteinternoenestructurasdezirconiaytriaelaboradasconlossistemascadcamproceraycerecinlabmarginaladaptationandinternalfitofzirconiaytryaframeworksfabricatedwithproceraandcerecinlabcadcamsystems
AT dianavirginiamarinmunoz adaptacionmarginalyajusteinternoenestructurasdezirconiaytriaelaboradasconlossistemascadcamproceraycerecinlabmarginaladaptationandinternalfitofzirconiaytryaframeworksfabricatedwithproceraandcerecinlabcadcamsystems
AT alejandroechavarriavelasquez adaptacionmarginalyajusteinternoenestructurasdezirconiaytriaelaboradasconlossistemascadcamproceraycerecinlabmarginaladaptationandinternalfitofzirconiaytryaframeworksfabricatedwithproceraandcerecinlabcadcamsystems
_version_ 1724508481555267584
spelling doaj-e39840c55d6e43e9af3a50e1b71ccdd72020-11-25T03:46:00ZengUniversidad de AntioquiaRevista Facultad de Odontología Universidad de Antioquia0121-246X2145-76702011-06-01222186197Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec in-Lab® Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systemsCarlos Bernardo Caparroso PérezDiana Virginia Marín MuñozAlejandro Echavarría VelásquezINTRODUCCIÓN: el objetivo fue determinar ex vivo la adaptación marginal y ajuste interno en estructuras de zirconiaytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab®. MÉTODOS: se tomaron 15 pilares protésicos prefabricados contorneados de implantes divididos en tres grupos. Se fabricaron estructuras en aleación noble Pd-Au (control), Procera All Zircon® y Cerec In-lab YZ cubes®. Para evaluar la adaptación marginal se tomaron ocho medidas en la circunferencia del pilar protésico, tomando la distancia entre el borde de la estructura y el pilar. Para determinar el ajuste interno se hicieron ocho medidas desde la superficie externa del pilar a la superficie interna de la restauración. Las mediciones fueron hechas por microscopia óptica (50X). Los datos obtenidos fueron analizados por medio del análisis de varianza de una vía, la t de Student y prueba de Dunnett. RESULTADOS: el promedio de adaptación marginal del grupo control fue 18,24 &micro;m &plusmn;4,81; el grupo Procera® 21,62 &micro;m &plusmn;12,15 y el grupo Cerec In-lab® de 47,34 &micro;m &plusmn;17,72. El promedio de ajuste interno para las estructuras Pd-Au fue 34,60 &micro;m &plusmn;16,16; Procera® 118,67 &micro;m &plusmn;50,84 y el Cerec In-lab® 65,62 &micro;m &plusmn;25,80. CONCLUSIONES: los valores de adaptación marginal de las estructuras de aleación metálica y de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab® están entre los valores clínicamente aceptables. Las medidas de ajuste interno obtenidos para los grupos aleación metálica y Cerec® se encuentran dentro del rango reportado en la literatura. Mientras que el promedio obtenido para el grupo Procera® 118,67 &micro;m &plusmn;50,84, aunque se acercó al límite máximo de ajuste interno reportado en la literatura, no se evidenció diferencia estadísticamente significativa con el sistema Cerec In-lab®.<br>INTRODUCTION: the purpose of this in vitro study was to determine the marginal adaptation and internal fit in zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems. METHODS: fifteen prefabricated implant abutments were divided in three equally sized groups; noble metal alloy Pd-Au structures were then fabricated (control group), Procera® and Cerec In-lab YZ cubes® (n = 5). The marginal gap was determined by measuring 8 points around the abutment circumference taking the distance between the margin of the structure and the abutment. In order to determine internal fit, 8 measures were taken from the abutment&sbquo;s external surface to the internal surface of the restoration. The measures were done with an optical microscope (50X). The data was the statistically analyzed using 1-way ANOVA, Student&sbquo;s paired t test and Dunnett&sbquo;test. RESULTS: marginal adaptation mean for the control group was 18.24&plusmn;4.81&micro;m and Procera® 21.62 &micro;m &plusmn;12.15 &micro;m, while the average for Cerec In-lab® was 47.34 &micro;m &plusmn;17.72 &micro;m. The internal fit for the control group was 34,60 &micro;m &plusmn;16.16 &micro;m and Procera® group was of 118.67 &micro;m &plusmn;50.84 &micro;m in average and Cerec In-lab® 65.62 &micro;m &plusmn;25.80 &micro;m. CONCLUSION: the metal alloy and zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems showed clinically acceptable marginal gap values. The internal fit values for metal alloy and Cerec® frameworks are within the ranges reported in the literature. While the mean for the Procera® group was 118.67 &micro;m &plusmn;50.84, which is close to the internal fit maximum limit reported in the literature, there was no statistically significant difference when compared with the Cerec-In-lab® system.http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0121-246X2011000100006zirconia-ytria Procerazirconia ytria Cerec in-LabCAD/CAMadaptación marginalajuste internozirconia-ytria Procerazirconia ytria Cerec in-LabCAD/CAMmarginal adaptationinternal adjustment