Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single Subject

BackgroundMany adaptative deep brain stimulation (DBS) paradigms rely upon the ability to sense neural signatures of specific clinical signs or symptoms in order to modulate therapeutic stimulation. In first-generation bidirectional neurostimulators, the ability to sense neural signals during active...

Full description

Bibliographic Details
Main Authors: Daniel D. Cummins, Ryan B. Kochanski, Roee Gilron, Nicole C. Swann, Simon Little, Lauren H. Hammer, Philip A. Starr
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-08-01
Series:Frontiers in Neuroscience
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fnins.2021.725797/full
id doaj-e4589f501a904f8da92d52a99d082958
record_format Article
spelling doaj-e4589f501a904f8da92d52a99d0829582021-08-10T04:46:51ZengFrontiers Media S.A.Frontiers in Neuroscience1662-453X2021-08-011510.3389/fnins.2021.725797725797Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single SubjectDaniel D. Cummins0Ryan B. Kochanski1Roee Gilron2Nicole C. Swann3Simon Little4Lauren H. Hammer5Philip A. Starr6School of Medicine, University of California, San Francisco, San Francisco, CA, United StatesDepartment of Neurological Surgery, University of California, San Francisco, San Francisco, CA, United StatesDepartment of Neurological Surgery, University of California, San Francisco, San Francisco, CA, United StatesDepartment of Human Physiology, University of Oregon, Eugene, OR, United StatesDepartment of Neurology, University of California, San Francisco, San Francisco, CA, United StatesDepartment of Neurology, University of California, San Francisco, San Francisco, CA, United StatesDepartment of Neurological Surgery, University of California, San Francisco, San Francisco, CA, United StatesBackgroundMany adaptative deep brain stimulation (DBS) paradigms rely upon the ability to sense neural signatures of specific clinical signs or symptoms in order to modulate therapeutic stimulation. In first-generation bidirectional neurostimulators, the ability to sense neural signals during active stimulation was often limited by artifact. Newer devices, with improved design specifications for sensing, have recently been developed and are now clinically available.ObjectiveTo compare the sensing capabilities of the first-generation Medtronic PC + S and second-generation Percept PC neurostimulators within a single patient.MethodsA 42-year-old man with Parkinson’s disease was initially implanted with left STN DBS leads connected to a PC + S implantable pulse generator. Four years later, the PC + S was replaced with the Percept PC. Local field potential (LFP) signals were recorded, both with stimulation OFF and ON, at multiple timepoints with each device and compared. Offline processing of time series data included artifact removal using digital filtering and template subtraction, before subsequent spectral analysis. With Percept PC, embedded processing of spectral power within a narrow frequency band was also utilized.ResultsIn the absence of stimulation, both devices demonstrated a peak in the beta range (approximately 20 Hz), which was stable throughout the 4-year period. Similar to previous reports, recordings with the PC + S during active stimulation demonstrated significant stimulation artifact, limiting the ability to recover meaningful LFP signal. In contrast, the Percept PC, using the same electrodes and stimulation settings, produced time series data during stimulation with spectral analysis revealing a peak in the beta-band. Online analysis by the Percept demonstrated a reduction in beta-band activity with increasing stimulation amplitude.ConclusionThis report highlights recent advances in implantable neurostimulator technology for DBS, demonstrating improvements in sensing capabilities during active stimulation between first- and second-generation devices. The ability to reliably sense during stimulation is an important step toward both the clinical implementation of adaptive algorithms and the further investigation into the neurophysiology underlying movement disorders.https://www.frontiersin.org/articles/10.3389/fnins.2021.725797/fulldeep brain stimulationsubthalamic nucleusbidirectional neural interfacelocal field potentialbeta oscillations
collection DOAJ
language English
format Article
sources DOAJ
author Daniel D. Cummins
Ryan B. Kochanski
Roee Gilron
Nicole C. Swann
Simon Little
Lauren H. Hammer
Philip A. Starr
spellingShingle Daniel D. Cummins
Ryan B. Kochanski
Roee Gilron
Nicole C. Swann
Simon Little
Lauren H. Hammer
Philip A. Starr
Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single Subject
Frontiers in Neuroscience
deep brain stimulation
subthalamic nucleus
bidirectional neural interface
local field potential
beta oscillations
author_facet Daniel D. Cummins
Ryan B. Kochanski
Roee Gilron
Nicole C. Swann
Simon Little
Lauren H. Hammer
Philip A. Starr
author_sort Daniel D. Cummins
title Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single Subject
title_short Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single Subject
title_full Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single Subject
title_fullStr Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single Subject
title_full_unstemmed Chronic Sensing of Subthalamic Local Field Potentials: Comparison of First and Second Generation Implantable Bidirectional Systems Within a Single Subject
title_sort chronic sensing of subthalamic local field potentials: comparison of first and second generation implantable bidirectional systems within a single subject
publisher Frontiers Media S.A.
series Frontiers in Neuroscience
issn 1662-453X
publishDate 2021-08-01
description BackgroundMany adaptative deep brain stimulation (DBS) paradigms rely upon the ability to sense neural signatures of specific clinical signs or symptoms in order to modulate therapeutic stimulation. In first-generation bidirectional neurostimulators, the ability to sense neural signals during active stimulation was often limited by artifact. Newer devices, with improved design specifications for sensing, have recently been developed and are now clinically available.ObjectiveTo compare the sensing capabilities of the first-generation Medtronic PC + S and second-generation Percept PC neurostimulators within a single patient.MethodsA 42-year-old man with Parkinson’s disease was initially implanted with left STN DBS leads connected to a PC + S implantable pulse generator. Four years later, the PC + S was replaced with the Percept PC. Local field potential (LFP) signals were recorded, both with stimulation OFF and ON, at multiple timepoints with each device and compared. Offline processing of time series data included artifact removal using digital filtering and template subtraction, before subsequent spectral analysis. With Percept PC, embedded processing of spectral power within a narrow frequency band was also utilized.ResultsIn the absence of stimulation, both devices demonstrated a peak in the beta range (approximately 20 Hz), which was stable throughout the 4-year period. Similar to previous reports, recordings with the PC + S during active stimulation demonstrated significant stimulation artifact, limiting the ability to recover meaningful LFP signal. In contrast, the Percept PC, using the same electrodes and stimulation settings, produced time series data during stimulation with spectral analysis revealing a peak in the beta-band. Online analysis by the Percept demonstrated a reduction in beta-band activity with increasing stimulation amplitude.ConclusionThis report highlights recent advances in implantable neurostimulator technology for DBS, demonstrating improvements in sensing capabilities during active stimulation between first- and second-generation devices. The ability to reliably sense during stimulation is an important step toward both the clinical implementation of adaptive algorithms and the further investigation into the neurophysiology underlying movement disorders.
topic deep brain stimulation
subthalamic nucleus
bidirectional neural interface
local field potential
beta oscillations
url https://www.frontiersin.org/articles/10.3389/fnins.2021.725797/full
work_keys_str_mv AT danieldcummins chronicsensingofsubthalamiclocalfieldpotentialscomparisonoffirstandsecondgenerationimplantablebidirectionalsystemswithinasinglesubject
AT ryanbkochanski chronicsensingofsubthalamiclocalfieldpotentialscomparisonoffirstandsecondgenerationimplantablebidirectionalsystemswithinasinglesubject
AT roeegilron chronicsensingofsubthalamiclocalfieldpotentialscomparisonoffirstandsecondgenerationimplantablebidirectionalsystemswithinasinglesubject
AT nicolecswann chronicsensingofsubthalamiclocalfieldpotentialscomparisonoffirstandsecondgenerationimplantablebidirectionalsystemswithinasinglesubject
AT simonlittle chronicsensingofsubthalamiclocalfieldpotentialscomparisonoffirstandsecondgenerationimplantablebidirectionalsystemswithinasinglesubject
AT laurenhhammer chronicsensingofsubthalamiclocalfieldpotentialscomparisonoffirstandsecondgenerationimplantablebidirectionalsystemswithinasinglesubject
AT philipastarr chronicsensingofsubthalamiclocalfieldpotentialscomparisonoffirstandsecondgenerationimplantablebidirectionalsystemswithinasinglesubject
_version_ 1721212939145314304