TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPA
In order to anticipate the impact of face loading due to severe earthquakes on infilled wall panels of a frame structure, the maximum area or span of these panels needs to be restricted as recommended in the Design Manual for Ordinary Reinforced Concrete Structures and Reinforced Wall Structures 198...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Petra Christian University
2000-01-01
|
Series: | Civil Engineering Dimension |
Subjects: | |
Online Access: | http://puslit2.petra.ac.id/ejournal/index.php/civ/article/view/15515 |
id |
doaj-e77704684f064fa1a42afef83e904d9a |
---|---|
record_format |
Article |
spelling |
doaj-e77704684f064fa1a42afef83e904d9a2020-11-25T02:41:27ZengPetra Christian UniversityCivil Engineering Dimension1410-95301979-570X2000-01-012118TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPAGideon Hadi KusumaTakim AndrionoIn order to anticipate the impact of face loading due to severe earthquakes on infilled wall panels of a frame structure, the maximum area or span of these panels needs to be restricted as recommended in the Design Manual for Ordinary Reinforced Concrete Structures and Reinforced Wall Structures 1983. However, this restriction is merely based on the seismic zone and soil condition where the structure is located; the wall's position, whether it is on the ground or top floor and whether it is located inside or on the perimeter of the building. A study which was carried out to re-evaluate the above recommendation found that there are some other parameters which need also to be considered, such as the width of brick units, the effective wall thickness, the ratio of clear height to span of wall panel. Furthermore, for design purposes, it is suggested to put into consideration the crack state condition of walls due to seismic face loads. Abstract in Bahasa Indonesia : Dalam rangka mengantisipasi terjadinya beban muka akibat gempa kuat yang bekerja pada bidang dinding pengisi suatu struktur rangka, luas maksimum atau bentang bidang dinding perlu dibatasi seperti yang direkomendasikan dalam Pedoman Perencanaan untuk Struktur Beton Bertulang Biasa dan Struktur Tembok Bertulang untuk Gedung 1983. Namun, pembatasan ini tampak hanya bergantung pada wilayah gempa dan kondisi tanah dimana bangunan berada serta posisi tembok, apakah di lantai dasar atau puncak gedung dan apakah dinding terletak di dalam atau di sekeliling luar bangunan. Sebuah studi yang telah dilakukan untuk mengevaluasi kembali ketentuan pembatasan tersebut di atas menyimpulkan bahwa terdapat beberapa parameter lain yang seharusnya juga diperhitungkan, seperti lebar unit bata, tebal efektif dinding, rasio tinggi beban dinding terhadap lebar bentangnya. Di samping itu, untuk keperluan perencanaan diusulkan pula agar tahap kondisi retak dinding akibat beban muka diperhitungkan pula. Kata kunci: tembok pengisi, beban muka, tahap kondisi retak tembok http://puslit2.petra.ac.id/ejournal/index.php/civ/article/view/15515infilled wallface loadingcrack state condition of walls. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gideon Hadi Kusuma Takim Andriono |
spellingShingle |
Gideon Hadi Kusuma Takim Andriono TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPA Civil Engineering Dimension infilled wall face loading crack state condition of walls. |
author_facet |
Gideon Hadi Kusuma Takim Andriono |
author_sort |
Gideon Hadi Kusuma |
title |
TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPA |
title_short |
TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPA |
title_full |
TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPA |
title_fullStr |
TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPA |
title_full_unstemmed |
TINJAUAN TERHADAP PEMBATASAN DIMENSI TEMBOK PENGISI YANG MENERIMA BEBAN MUKA AKIBAT GEMPA |
title_sort |
tinjauan terhadap pembatasan dimensi tembok pengisi yang menerima beban muka akibat gempa |
publisher |
Petra Christian University |
series |
Civil Engineering Dimension |
issn |
1410-9530 1979-570X |
publishDate |
2000-01-01 |
description |
In order to anticipate the impact of face loading due to severe earthquakes on infilled wall panels of a frame structure, the maximum area or span of these panels needs to be restricted as recommended in the Design Manual for Ordinary Reinforced Concrete Structures and Reinforced Wall Structures 1983. However, this restriction is merely based on the seismic zone and soil condition where the structure is located; the wall's position, whether it is on the ground or top floor and whether it is located inside or on the perimeter of the building. A study which was carried out to re-evaluate the above recommendation found that there are some other parameters which need also to be considered, such as the width of brick units, the effective wall thickness, the ratio of clear height to span of wall panel. Furthermore, for design purposes, it is suggested to put into consideration the crack state condition of walls due to seismic face loads. Abstract in Bahasa Indonesia : Dalam rangka mengantisipasi terjadinya beban muka akibat gempa kuat yang bekerja pada bidang dinding pengisi suatu struktur rangka, luas maksimum atau bentang bidang dinding perlu dibatasi seperti yang direkomendasikan dalam Pedoman Perencanaan untuk Struktur Beton Bertulang Biasa dan Struktur Tembok Bertulang untuk Gedung 1983. Namun, pembatasan ini tampak hanya bergantung pada wilayah gempa dan kondisi tanah dimana bangunan berada serta posisi tembok, apakah di lantai dasar atau puncak gedung dan apakah dinding terletak di dalam atau di sekeliling luar bangunan. Sebuah studi yang telah dilakukan untuk mengevaluasi kembali ketentuan pembatasan tersebut di atas menyimpulkan bahwa terdapat beberapa parameter lain yang seharusnya juga diperhitungkan, seperti lebar unit bata, tebal efektif dinding, rasio tinggi beban dinding terhadap lebar bentangnya. Di samping itu, untuk keperluan perencanaan diusulkan pula agar tahap kondisi retak dinding akibat beban muka diperhitungkan pula. Kata kunci: tembok pengisi, beban muka, tahap kondisi retak tembok |
topic |
infilled wall face loading crack state condition of walls. |
url |
http://puslit2.petra.ac.id/ejournal/index.php/civ/article/view/15515 |
work_keys_str_mv |
AT gideonhadikusuma tinjauanterhadappembatasandimensitembokpengisiyangmenerimabebanmukaakibatgempa AT takimandriono tinjauanterhadappembatasandimensitembokpengisiyangmenerimabebanmukaakibatgempa |
_version_ |
1724778325830795264 |