Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducti...

Full description

Bibliographic Details
Main Authors: R. Voutta, S. Gerstl, S. Casalbuoni, A. W. Grau, T. Holubek, D. Saez de Jauregui, R. Bartolini, M. P. Cox, E. C. Longhi, G. Rehm, J. C. Schouten, R. P. Walker, M. Migliorati, B. Spataro
Format: Article
Language:English
Published: American Physical Society 2016-05-01
Series:Physical Review Accelerators and Beams
Online Access:http://doi.org/10.1103/PhysRevAccelBeams.19.053201
id doaj-e7fbd842b4fa4cac94e751eae8a3a96b
record_format Article
spelling doaj-e7fbd842b4fa4cac94e751eae8a3a96b2020-11-24T20:49:08ZengAmerican Physical SocietyPhysical Review Accelerators and Beams2469-98882016-05-0119505320110.1103/PhysRevAccelBeams.19.053201Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurementsR. VouttaS. GerstlS. CasalbuoniA. W. GrauT. HolubekD. Saez de JaureguiR. BartoliniM. P. CoxE. C. LonghiG. RehmJ. C. SchoutenR. P. WalkerM. MiglioratiB. SpataroThe beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS). In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014)]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.http://doi.org/10.1103/PhysRevAccelBeams.19.053201
collection DOAJ
language English
format Article
sources DOAJ
author R. Voutta
S. Gerstl
S. Casalbuoni
A. W. Grau
T. Holubek
D. Saez de Jauregui
R. Bartolini
M. P. Cox
E. C. Longhi
G. Rehm
J. C. Schouten
R. P. Walker
M. Migliorati
B. Spataro
spellingShingle R. Voutta
S. Gerstl
S. Casalbuoni
A. W. Grau
T. Holubek
D. Saez de Jauregui
R. Bartolini
M. P. Cox
E. C. Longhi
G. Rehm
J. C. Schouten
R. P. Walker
M. Migliorati
B. Spataro
Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements
Physical Review Accelerators and Beams
author_facet R. Voutta
S. Gerstl
S. Casalbuoni
A. W. Grau
T. Holubek
D. Saez de Jauregui
R. Bartolini
M. P. Cox
E. C. Longhi
G. Rehm
J. C. Schouten
R. P. Walker
M. Migliorati
B. Spataro
author_sort R. Voutta
title Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements
title_short Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements
title_full Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements
title_fullStr Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements
title_full_unstemmed Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements
title_sort cold vacuum chamber for diagnostics: analysis of the measurements at the diamond light source and impedance bench measurements
publisher American Physical Society
series Physical Review Accelerators and Beams
issn 2469-9888
publishDate 2016-05-01
description The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS). In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014)]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.
url http://doi.org/10.1103/PhysRevAccelBeams.19.053201
work_keys_str_mv AT rvoutta coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT sgerstl coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT scasalbuoni coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT awgrau coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT tholubek coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT dsaezdejauregui coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT rbartolini coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT mpcox coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT eclonghi coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT grehm coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT jcschouten coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT rpwalker coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT mmigliorati coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
AT bspataro coldvacuumchamberfordiagnosticsanalysisofthemeasurementsatthediamondlightsourceandimpedancebenchmeasurements
_version_ 1716806724744118272