Unit A1 of HE 'Pirot' excitation system parameter identification

In the paper, equivalent transfer function models of automatic and manual control of HE 'Pirot' unit A1 excitation system are presented. All determined parameter values are shown and discussed. Using experimentally derived step response records of the excitation system, the equivalent mode...

Full description

Bibliographic Details
Main Authors: Joksimović Dušan, Stojić Đorđe, Ćirić Zoran, Arnautović Dušan, Milinković Milan, Veinović Slavko, Milojčić Nemanja
Format: Article
Language:English
Published: Electrical Engineering Institute Nikola Tesla 2015-01-01
Series:Zbornik Radova: Elektrotehnički Institut "Nikola Tesla"
Subjects:
Online Access:http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2015/0350-85281525155J.pdf
id doaj-e89595c9a1724979b3b7d9d833ce48da
record_format Article
spelling doaj-e89595c9a1724979b3b7d9d833ce48da2020-11-24T23:45:13ZengElectrical Engineering Institute Nikola TeslaZbornik Radova: Elektrotehnički Institut "Nikola Tesla"0350-85282406-12122015-01-0120152515517010.5937/zeint25-92330350-85281525155JUnit A1 of HE 'Pirot' excitation system parameter identificationJoksimović Dušan0Stojić Đorđe1Ćirić Zoran2Arnautović Dušan3Milinković Milan4Veinović Slavko5Milojčić Nemanja6University of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaIn the paper, equivalent transfer function models of automatic and manual control of HE 'Pirot' unit A1 excitation system are presented. All determined parameter values are shown and discussed. Using experimentally derived step response records of the excitation system, the equivalent model parameters are identified and compared to previously adjusted values. The reactive voltage drops at generator terminals, as well as at the HV side of the step-up transformer, are determined.http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2015/0350-85281525155J.pdfexcitation systemgenerator voltage regulationgenerator equivalent modelparameter identification
collection DOAJ
language English
format Article
sources DOAJ
author Joksimović Dušan
Stojić Đorđe
Ćirić Zoran
Arnautović Dušan
Milinković Milan
Veinović Slavko
Milojčić Nemanja
spellingShingle Joksimović Dušan
Stojić Đorđe
Ćirić Zoran
Arnautović Dušan
Milinković Milan
Veinović Slavko
Milojčić Nemanja
Unit A1 of HE 'Pirot' excitation system parameter identification
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla"
excitation system
generator voltage regulation
generator equivalent model
parameter identification
author_facet Joksimović Dušan
Stojić Đorđe
Ćirić Zoran
Arnautović Dušan
Milinković Milan
Veinović Slavko
Milojčić Nemanja
author_sort Joksimović Dušan
title Unit A1 of HE 'Pirot' excitation system parameter identification
title_short Unit A1 of HE 'Pirot' excitation system parameter identification
title_full Unit A1 of HE 'Pirot' excitation system parameter identification
title_fullStr Unit A1 of HE 'Pirot' excitation system parameter identification
title_full_unstemmed Unit A1 of HE 'Pirot' excitation system parameter identification
title_sort unit a1 of he 'pirot' excitation system parameter identification
publisher Electrical Engineering Institute Nikola Tesla
series Zbornik Radova: Elektrotehnički Institut "Nikola Tesla"
issn 0350-8528
2406-1212
publishDate 2015-01-01
description In the paper, equivalent transfer function models of automatic and manual control of HE 'Pirot' unit A1 excitation system are presented. All determined parameter values are shown and discussed. Using experimentally derived step response records of the excitation system, the equivalent model parameters are identified and compared to previously adjusted values. The reactive voltage drops at generator terminals, as well as at the HV side of the step-up transformer, are determined.
topic excitation system
generator voltage regulation
generator equivalent model
parameter identification
url http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2015/0350-85281525155J.pdf
work_keys_str_mv AT joksimovicdusan unita1ofhepirotexcitationsystemparameteridentification
AT stojicđorđe unita1ofhepirotexcitationsystemparameteridentification
AT ciriczoran unita1ofhepirotexcitationsystemparameteridentification
AT arnautovicdusan unita1ofhepirotexcitationsystemparameteridentification
AT milinkovicmilan unita1ofhepirotexcitationsystemparameteridentification
AT veinovicslavko unita1ofhepirotexcitationsystemparameteridentification
AT milojcicnemanja unita1ofhepirotexcitationsystemparameteridentification
_version_ 1725496751623766016