Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator

It is necessary to make sure that the operation of cooling installations of hydro generators could be made in conditions of enhanced security so that the probability of defects occurrence during their exploitation be practically null. The asynchronous regime of direct network start up is accompa...

Full description

Bibliographic Details
Main Authors: Ioan Pădureanu, Marcel Jurcu, Ladislau Augustinov, Cornel Hațiegan, Eugen Răduca, Laurențiu Pădeanu
Format: Article
Language:English
Published: Eftimie Murgu University of Resita 2015-07-01
Series:Analele Universităţii "Eftimie Murgu" Reşiţa: Fascicola I, Inginerie
Subjects:
Online Access:http://anale-ing.uem.ro/2015/36.pdf
id doaj-e8f16091eea541a3979754f4ca6e9801
record_format Article
spelling doaj-e8f16091eea541a3979754f4ca6e98012020-11-25T03:18:20ZengEftimie Murgu University of ResitaAnalele Universităţii "Eftimie Murgu" Reşiţa: Fascicola I, Inginerie1453-73971453-73972015-07-01XXII1345358Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator Ioan Pădureanu0Marcel Jurcu1Ladislau Augustinov2Cornel Hațiegan3Eugen Răduca4Laurențiu Pădeanu 5Eftimie Murgu University of ResitaEftimie Murgu University of ResitaEftimie Murgu University of ResitaEftimie Murgu University of ResitaEftimie Murgu University of ResitaPolitehnica University of TimisoaraIt is necessary to make sure that the operation of cooling installations of hydro generators could be made in conditions of enhanced security so that the probability of defects occurrence during their exploitation be practically null. The asynchronous regime of direct network start up is accompanied by very high values of the start-up current, associated with important voltage drops on supply cables, which results in the extension of the motor starting time. The present paper shows an efficient method of driving the cooling water pumps by the supply of electric driving motors with variable frequency. http://anale-ing.uem.ro/2015/36.pdfhydro generatoroptimisationasynchronous motorpumpsvariable efficiency.
collection DOAJ
language English
format Article
sources DOAJ
author Ioan Pădureanu
Marcel Jurcu
Ladislau Augustinov
Cornel Hațiegan
Eugen Răduca
Laurențiu Pădeanu
spellingShingle Ioan Pădureanu
Marcel Jurcu
Ladislau Augustinov
Cornel Hațiegan
Eugen Răduca
Laurențiu Pădeanu
Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator
Analele Universităţii "Eftimie Murgu" Reşiţa: Fascicola I, Inginerie
hydro generator
optimisation
asynchronous motor
pumps
variable efficiency.
author_facet Ioan Pădureanu
Marcel Jurcu
Ladislau Augustinov
Cornel Hațiegan
Eugen Răduca
Laurențiu Pădeanu
author_sort Ioan Pădureanu
title Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator
title_short Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator
title_full Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator
title_fullStr Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator
title_full_unstemmed Optimisation of the Start-up and Operation Regimes of Cooling Water Pumps of a High-Power Hydro Generator
title_sort optimisation of the start-up and operation regimes of cooling water pumps of a high-power hydro generator
publisher Eftimie Murgu University of Resita
series Analele Universităţii "Eftimie Murgu" Reşiţa: Fascicola I, Inginerie
issn 1453-7397
1453-7397
publishDate 2015-07-01
description It is necessary to make sure that the operation of cooling installations of hydro generators could be made in conditions of enhanced security so that the probability of defects occurrence during their exploitation be practically null. The asynchronous regime of direct network start up is accompanied by very high values of the start-up current, associated with important voltage drops on supply cables, which results in the extension of the motor starting time. The present paper shows an efficient method of driving the cooling water pumps by the supply of electric driving motors with variable frequency.
topic hydro generator
optimisation
asynchronous motor
pumps
variable efficiency.
url http://anale-ing.uem.ro/2015/36.pdf
work_keys_str_mv AT ioanpadureanu optimisationofthestartupandoperationregimesofcoolingwaterpumpsofahighpowerhydrogenerator
AT marceljurcu optimisationofthestartupandoperationregimesofcoolingwaterpumpsofahighpowerhydrogenerator
AT ladislauaugustinov optimisationofthestartupandoperationregimesofcoolingwaterpumpsofahighpowerhydrogenerator
AT cornelhatiegan optimisationofthestartupandoperationregimesofcoolingwaterpumpsofahighpowerhydrogenerator
AT eugenraduca optimisationofthestartupandoperationregimesofcoolingwaterpumpsofahighpowerhydrogenerator
AT laurentiupadeanu optimisationofthestartupandoperationregimesofcoolingwaterpumpsofahighpowerhydrogenerator
_version_ 1724627390826545152