ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOM

This paper is focused on analysis of neighboring noise as a disturbance agent. This problematics is closely connected with psychoacoustics or more generally with psychology. Therefore, methodology of research is based primarily on listening tests and questionnaires. The main research question lies i...

Full description

Bibliographic Details
Main Author: Jaroslav Hejl
Format: Article
Language:ces
Published: Czech Technical University, Prague 2017-04-01
Series:Civil Engineering Journal
Subjects:
Online Access:http://www.civilengineeringjournal.cz/archive/issues/2017/2017_1/1-2017-0009.pdf
id doaj-e94700149b504bccbcc533db24fc9995
record_format Article
spelling doaj-e94700149b504bccbcc533db24fc99952020-11-24T23:00:22ZcesCzech Technical University, PragueCivil Engineering Journal1805-25762017-04-0120171919810.14311/CEJ.2017.01.0009ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOMJaroslav Hejl01. Czech Technical University, Faculty of Civil Engineering, Department of buildings structures, Prague, Thákurova 7, Praha 6 - Dejvice, Czech RepublicThis paper is focused on analysis of neighboring noise as a disturbance agent. This problematics is closely connected with psychoacoustics or more generally with psychology. Therefore, methodology of research is based primarily on listening tests and questionnaires. The main research question lies in evaluation of difference of low/medium/high pitch noise on acoustic comfort of users. For purpose of this a method of auralization was introduced. The model was created by ODEON software and source noises were virtually reproduced through different partition walls. The virtual records in receiving room were accordingly replayed within listening tests. Results have shown that it is not easy to define one exact formula and answers depend on exact sounds and even there is not agreement through all of respondents. It should be mentioned that amount of respondents is too small for any definite statements. However, there is non-obvious and unexpected inclination to evaluated multi-layered light-weight structures as subjectively worse than adequately insulating concrete wall – at least from results obtained in this test. The possible explanation is an unnatural frequency spectrum of resulting sounds which are perceived as more disturbing despite they have lower sound pressure levels then in case of structure from reinforced concrete.http://www.civilengineeringjournal.cz/archive/issues/2017/2017_1/1-2017-0009.pdfListening testsauralizationfrequencysound reduction indexsubjective evaluation
collection DOAJ
language ces
format Article
sources DOAJ
author Jaroslav Hejl
spellingShingle Jaroslav Hejl
ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOM
Civil Engineering Journal
Listening tests
auralization
frequency
sound reduction index
subjective evaluation
author_facet Jaroslav Hejl
author_sort Jaroslav Hejl
title ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOM
title_short ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOM
title_full ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOM
title_fullStr ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOM
title_full_unstemmed ANALYSIS OF NEIGHBOURING NOISE DISTURBANCE IN RECEIVING ROOM
title_sort analysis of neighbouring noise disturbance in receiving room
publisher Czech Technical University, Prague
series Civil Engineering Journal
issn 1805-2576
publishDate 2017-04-01
description This paper is focused on analysis of neighboring noise as a disturbance agent. This problematics is closely connected with psychoacoustics or more generally with psychology. Therefore, methodology of research is based primarily on listening tests and questionnaires. The main research question lies in evaluation of difference of low/medium/high pitch noise on acoustic comfort of users. For purpose of this a method of auralization was introduced. The model was created by ODEON software and source noises were virtually reproduced through different partition walls. The virtual records in receiving room were accordingly replayed within listening tests. Results have shown that it is not easy to define one exact formula and answers depend on exact sounds and even there is not agreement through all of respondents. It should be mentioned that amount of respondents is too small for any definite statements. However, there is non-obvious and unexpected inclination to evaluated multi-layered light-weight structures as subjectively worse than adequately insulating concrete wall – at least from results obtained in this test. The possible explanation is an unnatural frequency spectrum of resulting sounds which are perceived as more disturbing despite they have lower sound pressure levels then in case of structure from reinforced concrete.
topic Listening tests
auralization
frequency
sound reduction index
subjective evaluation
url http://www.civilengineeringjournal.cz/archive/issues/2017/2017_1/1-2017-0009.pdf
work_keys_str_mv AT jaroslavhejl analysisofneighbouringnoisedisturbanceinreceivingroom
_version_ 1725642444898304000