Copper-Graphene-Based Photonic Crystal Fiber Plasmonic Biosensor

We propose a photonic crystal fiber surface plasmon resonance biosensor where the plasmonic metal layer and the sensing layer are placed outside the fiber structure, which makes the sensor configuration practically simpler and the sensing process more straightforward. Considering the long-term stabi...

Full description

Bibliographic Details
Main Authors: Ahmmed A. Rifat, G. Amouzad Mahdiraji, Rajib Ahmed, Desmond M. Chow, Y. M. Sua, Y. G. Shee, F. R. Mahamd Adikan
Format: Article
Language:English
Published: IEEE 2016-01-01
Series:IEEE Photonics Journal
Subjects:
Online Access:https://ieeexplore.ieee.org/document/7361738/
id doaj-ea66a4ba78a640e3b6e8b6aae618930f
record_format Article
spelling doaj-ea66a4ba78a640e3b6e8b6aae618930f2021-03-29T17:29:59ZengIEEEIEEE Photonics Journal1943-06552016-01-01811810.1109/JPHOT.2015.25106327361738Copper-Graphene-Based Photonic Crystal Fiber Plasmonic BiosensorAhmmed A. Rifat0G. Amouzad Mahdiraji1Rajib Ahmed2Desmond M. Chow3Y. M. Sua4Y. G. Shee5F. R. Mahamd Adikan6Integrated Lightwave Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, MalaysiaIntegrated Lightwave Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, MalaysiaNanotechnology Laboratory, School of Mechanical Engineering, University of Birmingham, Birmingham, U.K.Integrated Lightwave Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, MalaysiaIntegrated Lightwave Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, MalaysiaIntegrated Lightwave Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, MalaysiaIntegrated Lightwave Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, MalaysiaWe propose a photonic crystal fiber surface plasmon resonance biosensor where the plasmonic metal layer and the sensing layer are placed outside the fiber structure, which makes the sensor configuration practically simpler and the sensing process more straightforward. Considering the long-term stability of the plasmonic performance, copper (Cu) is used as the plasmonic material, and graphene is used to prevent Cu oxidation and enhance sensing performance. Numerical investigation of guiding properties and sensing performance is performed by using a finite-element method. The proposed sensor shows average wavelength interrogation sensitivity of 2000 nm/refractive index unit (RIU) over the analyte refractive indices ranging from 1.33 to 1.37, which leads to a sensor resolution of 5 &#x00D7; 10<sup>-5</sup> RIU. Due to the simple structure and promising results, the proposed sensor could be a potential candidate for detecting biomolecules, organic chemicals, and other analytes.https://ieeexplore.ieee.org/document/7361738/Photonic crystal fibersurface plasmon resonanceoptical fiber sensorsoptical sensing and sensors
collection DOAJ
language English
format Article
sources DOAJ
author Ahmmed A. Rifat
G. Amouzad Mahdiraji
Rajib Ahmed
Desmond M. Chow
Y. M. Sua
Y. G. Shee
F. R. Mahamd Adikan
spellingShingle Ahmmed A. Rifat
G. Amouzad Mahdiraji
Rajib Ahmed
Desmond M. Chow
Y. M. Sua
Y. G. Shee
F. R. Mahamd Adikan
Copper-Graphene-Based Photonic Crystal Fiber Plasmonic Biosensor
IEEE Photonics Journal
Photonic crystal fiber
surface plasmon resonance
optical fiber sensors
optical sensing and sensors
author_facet Ahmmed A. Rifat
G. Amouzad Mahdiraji
Rajib Ahmed
Desmond M. Chow
Y. M. Sua
Y. G. Shee
F. R. Mahamd Adikan
author_sort Ahmmed A. Rifat
title Copper-Graphene-Based Photonic Crystal Fiber Plasmonic Biosensor
title_short Copper-Graphene-Based Photonic Crystal Fiber Plasmonic Biosensor
title_full Copper-Graphene-Based Photonic Crystal Fiber Plasmonic Biosensor
title_fullStr Copper-Graphene-Based Photonic Crystal Fiber Plasmonic Biosensor
title_full_unstemmed Copper-Graphene-Based Photonic Crystal Fiber Plasmonic Biosensor
title_sort copper-graphene-based photonic crystal fiber plasmonic biosensor
publisher IEEE
series IEEE Photonics Journal
issn 1943-0655
publishDate 2016-01-01
description We propose a photonic crystal fiber surface plasmon resonance biosensor where the plasmonic metal layer and the sensing layer are placed outside the fiber structure, which makes the sensor configuration practically simpler and the sensing process more straightforward. Considering the long-term stability of the plasmonic performance, copper (Cu) is used as the plasmonic material, and graphene is used to prevent Cu oxidation and enhance sensing performance. Numerical investigation of guiding properties and sensing performance is performed by using a finite-element method. The proposed sensor shows average wavelength interrogation sensitivity of 2000 nm/refractive index unit (RIU) over the analyte refractive indices ranging from 1.33 to 1.37, which leads to a sensor resolution of 5 &#x00D7; 10<sup>-5</sup> RIU. Due to the simple structure and promising results, the proposed sensor could be a potential candidate for detecting biomolecules, organic chemicals, and other analytes.
topic Photonic crystal fiber
surface plasmon resonance
optical fiber sensors
optical sensing and sensors
url https://ieeexplore.ieee.org/document/7361738/
work_keys_str_mv AT ahmmedarifat coppergraphenebasedphotoniccrystalfiberplasmonicbiosensor
AT gamouzadmahdiraji coppergraphenebasedphotoniccrystalfiberplasmonicbiosensor
AT rajibahmed coppergraphenebasedphotoniccrystalfiberplasmonicbiosensor
AT desmondmchow coppergraphenebasedphotoniccrystalfiberplasmonicbiosensor
AT ymsua coppergraphenebasedphotoniccrystalfiberplasmonicbiosensor
AT ygshee coppergraphenebasedphotoniccrystalfiberplasmonicbiosensor
AT frmahamdadikan coppergraphenebasedphotoniccrystalfiberplasmonicbiosensor
_version_ 1724197788151971840