Suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study

Abstract Background Online hemodiafiltration (OL-HDF), whether in pre-dilution OL-HDF (pre-HDF) or post-dilution OL-HDF (post-HDF), is conducted to efficiently remove low molecular weight proteins from the blood of patients requiring dialysis. β2-microglobulin (β2-MG) and α1-microglobulin (α1-MG) ar...

Full description

Bibliographic Details
Main Authors: Kenji Sakurai, Hiromi Hosoya, Yoshitaka Kurihara, Takeshi Saito
Format: Article
Language:English
Published: BMC 2021-02-01
Series:Renal Replacement Therapy
Subjects:
Online Access:https://doi.org/10.1186/s41100-021-00326-y
id doaj-ec33e9c3ebe1489ba084e6dd38fc769d
record_format Article
spelling doaj-ec33e9c3ebe1489ba084e6dd38fc769d2021-02-21T12:47:48ZengBMCRenal Replacement Therapy2059-13812021-02-01711610.1186/s41100-021-00326-ySuitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort studyKenji Sakurai0Hiromi Hosoya1Yoshitaka Kurihara2Takeshi Saito3Hashimoto ClinicHashimoto ClinicHashimoto ClinicHashimoto ClinicAbstract Background Online hemodiafiltration (OL-HDF), whether in pre-dilution OL-HDF (pre-HDF) or post-dilution OL-HDF (post-HDF), is conducted to efficiently remove low molecular weight proteins from the blood of patients requiring dialysis. β2-microglobulin (β2-MG) and α1-microglobulin (α1-MG) are used as biomarkers to evaluate removal efficiency of OL-HDF. We aimed to evaluate the relationship between β2-MG and α1-MG reduction rates and the amount of albumin leakage. Furthermore, we statistically analyzed the relationship between the α1-MG reduction rate and α1-MG removal amount, and its suitability as a biomarker for evaluating the removal efficiency of OL-HDF. Methods We collected the results of regularly conducted routine evaluations to assess the efficiency of OL-HDF from cases of patients undergoing maintenance dialysis at our clinic from 2018 to 2019. Data on was collected on both pre-HDF and post-HDF sessions. β2-MG and α1-MG reduction rates were analyzed. Regression analysis on reduction rates showed a significant correlation between the α1-MG reduction rate and the α1-MG removal amount. Results We conducted 435 tests on OL-HDF efficiency in 87 cases undergoing maintenance dialysis at our clinic in 2018 and 2019. There were 80.7 ± 4.5% for the β2-MG reduction rate, 33.8 ± 9.4% for the α1-MG reduction rate, and 3.9 ± 1.8 g/s for the amount of albumin leakage. There was no correlation between the β2-MG reduction rate and the α1-MG reduction rate, or between the amount of albumin leakage and β2-MG reduction rate. Conclusion α1-MG reduction rate was found to correlate with its removal amount, demonstrating its suitability as a biomarker for evaluating the removal efficiency of OL-HDF. Trial registration Retrospectively registered.https://doi.org/10.1186/s41100-021-00326-yα1-microglobulinReduction rate of α1-microglobulinOnline hemodiafiltrationBiomarker for evaluation of removal efficiency
collection DOAJ
language English
format Article
sources DOAJ
author Kenji Sakurai
Hiromi Hosoya
Yoshitaka Kurihara
Takeshi Saito
spellingShingle Kenji Sakurai
Hiromi Hosoya
Yoshitaka Kurihara
Takeshi Saito
Suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study
Renal Replacement Therapy
α1-microglobulin
Reduction rate of α1-microglobulin
Online hemodiafiltration
Biomarker for evaluation of removal efficiency
author_facet Kenji Sakurai
Hiromi Hosoya
Yoshitaka Kurihara
Takeshi Saito
author_sort Kenji Sakurai
title Suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study
title_short Suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study
title_full Suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study
title_fullStr Suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study
title_full_unstemmed Suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study
title_sort suitability of α1-microglobulin reduction rate as a biomarker of removal efficiency of online hemodiafiltration: a retrospective cohort study
publisher BMC
series Renal Replacement Therapy
issn 2059-1381
publishDate 2021-02-01
description Abstract Background Online hemodiafiltration (OL-HDF), whether in pre-dilution OL-HDF (pre-HDF) or post-dilution OL-HDF (post-HDF), is conducted to efficiently remove low molecular weight proteins from the blood of patients requiring dialysis. β2-microglobulin (β2-MG) and α1-microglobulin (α1-MG) are used as biomarkers to evaluate removal efficiency of OL-HDF. We aimed to evaluate the relationship between β2-MG and α1-MG reduction rates and the amount of albumin leakage. Furthermore, we statistically analyzed the relationship between the α1-MG reduction rate and α1-MG removal amount, and its suitability as a biomarker for evaluating the removal efficiency of OL-HDF. Methods We collected the results of regularly conducted routine evaluations to assess the efficiency of OL-HDF from cases of patients undergoing maintenance dialysis at our clinic from 2018 to 2019. Data on was collected on both pre-HDF and post-HDF sessions. β2-MG and α1-MG reduction rates were analyzed. Regression analysis on reduction rates showed a significant correlation between the α1-MG reduction rate and the α1-MG removal amount. Results We conducted 435 tests on OL-HDF efficiency in 87 cases undergoing maintenance dialysis at our clinic in 2018 and 2019. There were 80.7 ± 4.5% for the β2-MG reduction rate, 33.8 ± 9.4% for the α1-MG reduction rate, and 3.9 ± 1.8 g/s for the amount of albumin leakage. There was no correlation between the β2-MG reduction rate and the α1-MG reduction rate, or between the amount of albumin leakage and β2-MG reduction rate. Conclusion α1-MG reduction rate was found to correlate with its removal amount, demonstrating its suitability as a biomarker for evaluating the removal efficiency of OL-HDF. Trial registration Retrospectively registered.
topic α1-microglobulin
Reduction rate of α1-microglobulin
Online hemodiafiltration
Biomarker for evaluation of removal efficiency
url https://doi.org/10.1186/s41100-021-00326-y
work_keys_str_mv AT kenjisakurai suitabilityofa1microglobulinreductionrateasabiomarkerofremovalefficiencyofonlinehemodiafiltrationaretrospectivecohortstudy
AT hiromihosoya suitabilityofa1microglobulinreductionrateasabiomarkerofremovalefficiencyofonlinehemodiafiltrationaretrospectivecohortstudy
AT yoshitakakurihara suitabilityofa1microglobulinreductionrateasabiomarkerofremovalefficiencyofonlinehemodiafiltrationaretrospectivecohortstudy
AT takeshisaito suitabilityofa1microglobulinreductionrateasabiomarkerofremovalefficiencyofonlinehemodiafiltrationaretrospectivecohortstudy
_version_ 1724257754600701952