Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up Results

Abstract Background: Left atrial appendage (LAA) occlusion is an alternative therapy for atrial fibrillation patients who have high embolic risk and contraindications to anticoagulant therapy. Objective: To evaluate the feasibility, safety, and mid-term outcomes of percutaneous LAA occlusion, incl...

Full description

Bibliographic Details
Main Authors: Mehmet Levent Şahiner, Ergun Baris Kaya, Cem Çöteli, Kudret Aytemir
Format: Article
Language:English
Published: Sociedade Brasileira de Cardiologia (SBC)
Series:Arquivos Brasileiros de Cardiologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2019005001302&lng=en&tlng=en
id doaj-ed388422f58c43a2b97b7735e2f4dfb9
record_format Article
spelling doaj-ed388422f58c43a2b97b7735e2f4dfb92020-11-24T21:23:55ZengSociedade Brasileira de Cardiologia (SBC)Arquivos Brasileiros de Cardiologia1678-417010.5935/abc.20190138S0066-782X2019005001302Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up ResultsMehmet Levent ŞahinerErgun Baris KayaCem ÇöteliKudret AytemirAbstract Background: Left atrial appendage (LAA) occlusion is an alternative therapy for atrial fibrillation patients who have high embolic risk and contraindications to anticoagulant therapy. Objective: To evaluate the feasibility, safety, and mid-term outcomes of percutaneous LAA occlusion, including device-related thrombosis. Methods: Sixty consecutive patients who had undergone percutaneous LAA occlusion with AMPLATZER™ Amulet™ device from September 2015 to March 2018 were enrolled. Patients were followed for 21 ± 15 months (median - 20 months, interquartile range - 9 to 27 months). The postprocedural assessment was done at the 1(st), 6(th), and 12(th) month. Patients were clinically evaluated, and transesophageal echocardiography was performed at each visit. We evaluated the condition of normality of variables using the Kolmogorov-Smirnov test. P-values < 0.05 were statistically significant. Results: The most common indication for the procedure was major bleeding with anticoagulants (n: 53, 88.3%). The procedure was completed successfully in 59 (98.3%) patients. Periprocedural mortality was observed in one patient. Postprocedural antiplatelet treatment was planned as dual or single antiplatelet therapy or low-dose anticoagulant therapy in 52 (88.1%), 2 (3.4%), and 5 (8.5%) patients, respectively. We found no clinically significant cerebrovascular events, device-related thrombus, or embolization in any patient during the follow-up. Two (3.4 %) patients presented significant peri-device leak (>3 mm) at the 1st month evaluation, which disappeared at the 12th month follow-up. Conclusion: We concluded that LAA occlusion using the Amulet™ LAA occluder can be performed with high procedural success and acceptable outcomes.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2019005001302&lng=en&tlng=enAtrial FibrillationAtrial AppendageMortalityEchocardiography/methodsCardiac CatheterizationAnticoagulants/therapeutic use
collection DOAJ
language English
format Article
sources DOAJ
author Mehmet Levent Şahiner
Ergun Baris Kaya
Cem Çöteli
Kudret Aytemir
spellingShingle Mehmet Levent Şahiner
Ergun Baris Kaya
Cem Çöteli
Kudret Aytemir
Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up Results
Arquivos Brasileiros de Cardiologia
Atrial Fibrillation
Atrial Appendage
Mortality
Echocardiography/methods
Cardiac Catheterization
Anticoagulants/therapeutic use
author_facet Mehmet Levent Şahiner
Ergun Baris Kaya
Cem Çöteli
Kudret Aytemir
author_sort Mehmet Levent Şahiner
title Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up Results
title_short Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up Results
title_full Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up Results
title_fullStr Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up Results
title_full_unstemmed Left Atrial Appendage Transcatheter Occlusion with AMPLATZER™ Amulet™ Device: Real Life Data with Mid-Term Follow-Up Results
title_sort left atrial appendage transcatheter occlusion with amplatzer™ amulet™ device: real life data with mid-term follow-up results
publisher Sociedade Brasileira de Cardiologia (SBC)
series Arquivos Brasileiros de Cardiologia
issn 1678-4170
description Abstract Background: Left atrial appendage (LAA) occlusion is an alternative therapy for atrial fibrillation patients who have high embolic risk and contraindications to anticoagulant therapy. Objective: To evaluate the feasibility, safety, and mid-term outcomes of percutaneous LAA occlusion, including device-related thrombosis. Methods: Sixty consecutive patients who had undergone percutaneous LAA occlusion with AMPLATZER™ Amulet™ device from September 2015 to March 2018 were enrolled. Patients were followed for 21 ± 15 months (median - 20 months, interquartile range - 9 to 27 months). The postprocedural assessment was done at the 1(st), 6(th), and 12(th) month. Patients were clinically evaluated, and transesophageal echocardiography was performed at each visit. We evaluated the condition of normality of variables using the Kolmogorov-Smirnov test. P-values < 0.05 were statistically significant. Results: The most common indication for the procedure was major bleeding with anticoagulants (n: 53, 88.3%). The procedure was completed successfully in 59 (98.3%) patients. Periprocedural mortality was observed in one patient. Postprocedural antiplatelet treatment was planned as dual or single antiplatelet therapy or low-dose anticoagulant therapy in 52 (88.1%), 2 (3.4%), and 5 (8.5%) patients, respectively. We found no clinically significant cerebrovascular events, device-related thrombus, or embolization in any patient during the follow-up. Two (3.4 %) patients presented significant peri-device leak (>3 mm) at the 1st month evaluation, which disappeared at the 12th month follow-up. Conclusion: We concluded that LAA occlusion using the Amulet™ LAA occluder can be performed with high procedural success and acceptable outcomes.
topic Atrial Fibrillation
Atrial Appendage
Mortality
Echocardiography/methods
Cardiac Catheterization
Anticoagulants/therapeutic use
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2019005001302&lng=en&tlng=en
work_keys_str_mv AT mehmetleventsahiner leftatrialappendagetranscatheterocclusionwithamplatzeramuletdevicereallifedatawithmidtermfollowupresults
AT ergunbariskaya leftatrialappendagetranscatheterocclusionwithamplatzeramuletdevicereallifedatawithmidtermfollowupresults
AT cemcoteli leftatrialappendagetranscatheterocclusionwithamplatzeramuletdevicereallifedatawithmidtermfollowupresults
AT kudretaytemir leftatrialappendagetranscatheterocclusionwithamplatzeramuletdevicereallifedatawithmidtermfollowupresults
_version_ 1725990405031329792