Switched Reluctance Generator Output Voltage Ripple Reduction Based on Fuzzy Sliding Mode

Aiming at the problem of Switched Reluctance Generator output voltage ripple, this paper designs a fuzzy sliding mode controller based on the analysis of various factors affecting the output voltage ripple. The traditional sliding mode controller has quick convergence, but it has chattering problem....

Full description

Bibliographic Details
Main Authors: Xia Fei, Xia Zongze, Huang Xiaobo, Wang Yun
Format: Article
Language:English
Published: EDP Sciences 2015-01-01
Series:MATEC Web of Conferences
Subjects:
Online Access:http://dx.doi.org/10.1051/matecconf/20152501001
Description
Summary:Aiming at the problem of Switched Reluctance Generator output voltage ripple, this paper designs a fuzzy sliding mode controller based on the analysis of various factors affecting the output voltage ripple. The traditional sliding mode controller has quick convergence, but it has chattering problem. This paper introduces the fuzzy control to select the appropriate sliding mode gain. It can combine with traditional angle control to adjust the output voltage by adjusting the conduction angle. It is more effective in shortening the adjustment time and reducing the overshoot and steady-state of error compared with the classical PID control. Meanwhile, it also solves the chattering problem of traditional sliding mode control. Finally, it makes use of nonlinear model structure to validate that it is effective in restraining voltage ripple and improving the dynamic performance of the system and the voltage quality.
ISSN:2261-236X