Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airway
The world is going through the COVID-19 pandemic, which has high virulence and transmission rate. More significant the viral load during exposure, the greater is the likelihood of contracting a severe disease. Healthcare workers (HCWs) involved in airway care of COVID-19 patients are at high risk of...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2020-01-01
|
Series: | Journal of Anaesthesiology Clinical Pharmacology |
Subjects: | |
Online Access: | http://www.joacp.org/article.asp?issn=0970-9185;year=2020;volume=36;issue=5;spage=157;epage=160;aulast=Bidkar |
id |
doaj-f0772e97f3f0468ebe01c4b311e3d32f |
---|---|
record_format |
Article |
spelling |
doaj-f0772e97f3f0468ebe01c4b311e3d32f2020-11-25T02:00:22ZengWolters Kluwer Medknow PublicationsJournal of Anaesthesiology Clinical Pharmacology0970-91852020-01-0136515716010.4103/joacp.JOACP_211_20Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airwayPrasanna BidkarUmesh GoneppanavarJasvinder KaurSrivats Valliyur RamamoorthyThe world is going through the COVID-19 pandemic, which has high virulence and transmission rate. More significant the viral load during exposure, the greater is the likelihood of contracting a severe disease. Healthcare workers (HCWs) involved in airway care of COVID-19 patients are at high risk of getting exposed to large viral loads during aerosol-generating actions such as coughing or sneezing by the patient or during procedures such as bag-mask ventilation, intubation, extubation, and nebulization. This viral load exposure to airway caregivers decreases considerably with the use of an aerosol box during intubation. The safety tent proposed in this article is useful in limiting the viral load that HCWs are exposed to during airway procedures. Its role can be expanded beyond just intubation to protect against all aerosol-generating actions and procedures involving the patient's airway.http://www.joacp.org/article.asp?issn=0970-9185;year=2020;volume=36;issue=5;spage=157;epage=160;aulast=Bidkaraerosol generating procedurescovid-19intubation boxsafety tent |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Prasanna Bidkar Umesh Goneppanavar Jasvinder Kaur Srivats Valliyur Ramamoorthy |
spellingShingle |
Prasanna Bidkar Umesh Goneppanavar Jasvinder Kaur Srivats Valliyur Ramamoorthy Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airway Journal of Anaesthesiology Clinical Pharmacology aerosol generating procedures covid-19 intubation box safety tent |
author_facet |
Prasanna Bidkar Umesh Goneppanavar Jasvinder Kaur Srivats Valliyur Ramamoorthy |
author_sort |
Prasanna Bidkar |
title |
Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airway |
title_short |
Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airway |
title_full |
Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airway |
title_fullStr |
Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airway |
title_full_unstemmed |
Safety tent for enhanced personal protection from aerosol-generating procedures while handling the COVID-19 patient airway |
title_sort |
safety tent for enhanced personal protection from aerosol-generating procedures while handling the covid-19 patient airway |
publisher |
Wolters Kluwer Medknow Publications |
series |
Journal of Anaesthesiology Clinical Pharmacology |
issn |
0970-9185 |
publishDate |
2020-01-01 |
description |
The world is going through the COVID-19 pandemic, which has high virulence and transmission rate. More significant the viral load during exposure, the greater is the likelihood of contracting a severe disease. Healthcare workers (HCWs) involved in airway care of COVID-19 patients are at high risk of getting exposed to large viral loads during aerosol-generating actions such as coughing or sneezing by the patient or during procedures such as bag-mask ventilation, intubation, extubation, and nebulization. This viral load exposure to airway caregivers decreases considerably with the use of an aerosol box during intubation. The safety tent proposed in this article is useful in limiting the viral load that HCWs are exposed to during airway procedures. Its role can be expanded beyond just intubation to protect against all aerosol-generating actions and procedures involving the patient's airway. |
topic |
aerosol generating procedures covid-19 intubation box safety tent |
url |
http://www.joacp.org/article.asp?issn=0970-9185;year=2020;volume=36;issue=5;spage=157;epage=160;aulast=Bidkar |
work_keys_str_mv |
AT prasannabidkar safetytentforenhancedpersonalprotectionfromaerosolgeneratingprocedureswhilehandlingthecovid19patientairway AT umeshgoneppanavar safetytentforenhancedpersonalprotectionfromaerosolgeneratingprocedureswhilehandlingthecovid19patientairway AT jasvinderkaur safetytentforenhancedpersonalprotectionfromaerosolgeneratingprocedureswhilehandlingthecovid19patientairway AT srivatsvalliyurramamoorthy safetytentforenhancedpersonalprotectionfromaerosolgeneratingprocedureswhilehandlingthecovid19patientairway |
_version_ |
1724961004229492736 |