Total Knee Replacement with iASSIST Navigation System

Background/Purpose: The iASSIST system is a novel navigation system for total knee replacement. It is based on accelerometers built within electronic pods attached to the instruments within the operative field. The objective of this study was to compare the accuracy of iASSIST navigation with that o...

Full description

Bibliographic Details
Main Authors: Lo Chi-Kin, Li Hok-Yin, Wong Yiu-Chung, Wai Yuk-Leung
Format: Article
Language:English
Published: SAGE Publishing 2018-06-01
Series:Journal of Orthopaedics, Trauma and Rehabilitation
Online Access:http://www.sciencedirect.com/science/article/pii/S2210491716300811
id doaj-f0fbaff4e34f4e48bec96a46c652ee16
record_format Article
spelling doaj-f0fbaff4e34f4e48bec96a46c652ee162020-11-25T03:08:24ZengSAGE PublishingJournal of Orthopaedics, Trauma and Rehabilitation2210-49172018-06-01242933Total Knee Replacement with iASSIST Navigation SystemLo Chi-Kin0Li Hok-Yin1Wong Yiu-Chung2Wai Yuk-Leung3Corresponding author.; Department of Orthopaedics and Traumatology, Yan Chai Hospital, Tsuen Wan, Hong Kong, ChinaDepartment of Orthopaedics and Traumatology, Yan Chai Hospital, Tsuen Wan, Hong Kong, ChinaDepartment of Orthopaedics and Traumatology, Yan Chai Hospital, Tsuen Wan, Hong Kong, ChinaDepartment of Orthopaedics and Traumatology, Yan Chai Hospital, Tsuen Wan, Hong Kong, ChinaBackground/Purpose: The iASSIST system is a novel navigation system for total knee replacement. It is based on accelerometers built within electronic pods attached to the instruments within the operative field. The objective of this study was to compare the accuracy of iASSIST navigation with that of the conventional alignment technique. Methods: A total of 91 patients (92 knees) retrospectively matched for age, gender, preoperative range of motion, and lower limb deformity underwent total knee replacement using iASSIST navigation (45 patients, 46 knees) or conventional instrumentation (46 patients, 46 knees). Operative time and radiological alignments were compared. Results: The use of iASSIST navigation resulted in fewer outliners (as defined by >3° deviation from the neutral mechanical axis) in lower limb alignment. Operative time with iASSIST navigation was not longer than that using conventional instruments.Conclusion: iASSIST navigation reduces the incidence of lower limb malalignment without adding extra time to the procedure. 中文摘要: 簡介: iASSIST是一個全新的全膝關節置換術電腦導航系統。本研究的目的是比較iASSIST 導航系統及傳統全膝關節置換術的準確性。 方法: 回顧性分析91位病人(92膝) 的全膝關節置換術,病人、年齡、性別、術前活動範圍和下肢畸形的狀態匹配。45位病人(46膝) 接受了iASSIST電腦導航全膝關節置換術。46位病人接受了傳統全膝關節置換術。我們對两組病人的手術時間及術前術後的影像對線進行了比較。 結果: 使用iASSIST電腦導航全膝關節置換術之整體下肢對線較傳統全膝關節置換術較少 對線異常值 (>3°偏離中立機械軸)。而使用iASSIST電腦導航全膝關節置換術之手術時間並不比傳統全膝關節置換術長。 結論: iASSIST電腦導航降低整體下肢對線出現偏差的機會,同時無需增加額外手術時間。 Keywords: arthroplasty, case–control studies, computer assisted, knee, operative time, replacement, surgeryhttp://www.sciencedirect.com/science/article/pii/S2210491716300811
collection DOAJ
language English
format Article
sources DOAJ
author Lo Chi-Kin
Li Hok-Yin
Wong Yiu-Chung
Wai Yuk-Leung
spellingShingle Lo Chi-Kin
Li Hok-Yin
Wong Yiu-Chung
Wai Yuk-Leung
Total Knee Replacement with iASSIST Navigation System
Journal of Orthopaedics, Trauma and Rehabilitation
author_facet Lo Chi-Kin
Li Hok-Yin
Wong Yiu-Chung
Wai Yuk-Leung
author_sort Lo Chi-Kin
title Total Knee Replacement with iASSIST Navigation System
title_short Total Knee Replacement with iASSIST Navigation System
title_full Total Knee Replacement with iASSIST Navigation System
title_fullStr Total Knee Replacement with iASSIST Navigation System
title_full_unstemmed Total Knee Replacement with iASSIST Navigation System
title_sort total knee replacement with iassist navigation system
publisher SAGE Publishing
series Journal of Orthopaedics, Trauma and Rehabilitation
issn 2210-4917
publishDate 2018-06-01
description Background/Purpose: The iASSIST system is a novel navigation system for total knee replacement. It is based on accelerometers built within electronic pods attached to the instruments within the operative field. The objective of this study was to compare the accuracy of iASSIST navigation with that of the conventional alignment technique. Methods: A total of 91 patients (92 knees) retrospectively matched for age, gender, preoperative range of motion, and lower limb deformity underwent total knee replacement using iASSIST navigation (45 patients, 46 knees) or conventional instrumentation (46 patients, 46 knees). Operative time and radiological alignments were compared. Results: The use of iASSIST navigation resulted in fewer outliners (as defined by >3° deviation from the neutral mechanical axis) in lower limb alignment. Operative time with iASSIST navigation was not longer than that using conventional instruments.Conclusion: iASSIST navigation reduces the incidence of lower limb malalignment without adding extra time to the procedure. 中文摘要: 簡介: iASSIST是一個全新的全膝關節置換術電腦導航系統。本研究的目的是比較iASSIST 導航系統及傳統全膝關節置換術的準確性。 方法: 回顧性分析91位病人(92膝) 的全膝關節置換術,病人、年齡、性別、術前活動範圍和下肢畸形的狀態匹配。45位病人(46膝) 接受了iASSIST電腦導航全膝關節置換術。46位病人接受了傳統全膝關節置換術。我們對两組病人的手術時間及術前術後的影像對線進行了比較。 結果: 使用iASSIST電腦導航全膝關節置換術之整體下肢對線較傳統全膝關節置換術較少 對線異常值 (>3°偏離中立機械軸)。而使用iASSIST電腦導航全膝關節置換術之手術時間並不比傳統全膝關節置換術長。 結論: iASSIST電腦導航降低整體下肢對線出現偏差的機會,同時無需增加額外手術時間。 Keywords: arthroplasty, case–control studies, computer assisted, knee, operative time, replacement, surgery
url http://www.sciencedirect.com/science/article/pii/S2210491716300811
work_keys_str_mv AT lochikin totalkneereplacementwithiassistnavigationsystem
AT lihokyin totalkneereplacementwithiassistnavigationsystem
AT wongyiuchung totalkneereplacementwithiassistnavigationsystem
AT waiyukleung totalkneereplacementwithiassistnavigationsystem
_version_ 1724666611672023040