CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSIS

The capability of initial microbial adhesion to dental restorative composites surface is influenced by the surface wettability of the materials. The common method to evaluate surface wettability of materials is contact angle measurement. The existing conventional method to measure contact angle is b...

Full description

Bibliographic Details
Main Author: H. D. K. Yulianto dan M. Rinastiti
Format: Article
Language:English
Published: Universitas Gadjah Mada 2014-06-01
Series:Jurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi
Subjects:
Online Access:https://jurnal.ugm.ac.id/teknosains/article/view/6023
id doaj-f11ce8507ae549e9a2bbb3c4b265c84b
record_format Article
spelling doaj-f11ce8507ae549e9a2bbb3c4b265c84b2020-11-24T21:17:48ZengUniversitas Gadjah MadaJurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi2089-61312443-13112014-06-013210.22146/teknosains.60235207CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSISH. D. K. Yulianto dan M. Rinastiti0Faculty of Dentistry Universitas Gadjah MadaThe capability of initial microbial adhesion to dental restorative composites surface is influenced by the surface wettability of the materials. The common method to evaluate surface wettability of materials is contact angle measurement. The existing conventional method to measure contact angle is by means of a contact angle (CA)-Goniometer device, which is less practically applicable in clinical circumstances. Therefore, a more practical and applicable method is needed to measure contact angle in clinical circumstances. This research was performed to compare between contact angles measured by means of a CA-Goniometer device and a new practical method of drop profile image analysis. In addition, since there were two different formulas that can be used to calculate contact angle value from a drop profile image, then we also need to evaluate which formula is more reliable to be used. Tests were carried out using three composite discs (Clearfill-Kuraray Medical, Inc.) sample and deionised water for different measurement procedures. One drop of 3µl liquid was dropped onto the surface of the composite discs, and the drop profile image was captured by means of a customized home-made device connected to a digital camera. Two different formulas were used to calculate the contact angle value from the drop profile image, namely the “linier gradient equation” and the “tangential line”. The contact angle values obtained from the two different formulas were compared with the value obtained from the conventional method descriptively. Tests were carried out using three composite discs (Clearfill-Kuraray Medical, Inc.) sample and deionised water for different measurement procedures. One drop of 3µl liquid was dropped onto the surface of the composite discs, and the drop profile image was captured by means of a customized home-made device connected to a digital camera. Two different formulas were used to calculate the contact angle value from the drop profile image, namely the “linier gradient equation” and the “tangential line”. The contact angle values obtained from the two different formulas were compared with the value obtained from the conventional method descriptively. The differences in percentage between the contact angle value calculated by the “linier gradient equation” and “tangential line” formulas, and those calculated by means of the CA-Goniometer are 20,56% and 3,51%, respectively. It is obviously demonstrated that the value obtained by the “tangential line” formula has a smaller difference compared to those obtained by the “linier equation gradient” formula. Among the two different formulas, it is confirmed that the contact angle value calculated with the “tangential line” formula has closer similarity with the value obtained from the CA-Goniometer. This result confirms that the new practical method of drop profile image analysis is promising for measuring contact angle values in clinical circumstances. Related to the drop profile image analysis, the “tangential line” formula is more accurate compared to the “linier gradient equation” formula.https://jurnal.ugm.ac.id/teknosains/article/view/6023Contact angle, Microbial adhesion, Dentalrestorative materials
collection DOAJ
language English
format Article
sources DOAJ
author H. D. K. Yulianto dan M. Rinastiti
spellingShingle H. D. K. Yulianto dan M. Rinastiti
CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSIS
Jurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi
Contact angle, Microbial adhesion, Dentalrestorative materials
author_facet H. D. K. Yulianto dan M. Rinastiti
author_sort H. D. K. Yulianto dan M. Rinastiti
title CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSIS
title_short CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSIS
title_full CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSIS
title_fullStr CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSIS
title_full_unstemmed CONTACT ANGLE MEASUREMENT OF DENTAL RESTORATIVE MATERIALS BY DROP PROFILE IMAGE ANALYSIS
title_sort contact angle measurement of dental restorative materials by drop profile image analysis
publisher Universitas Gadjah Mada
series Jurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi
issn 2089-6131
2443-1311
publishDate 2014-06-01
description The capability of initial microbial adhesion to dental restorative composites surface is influenced by the surface wettability of the materials. The common method to evaluate surface wettability of materials is contact angle measurement. The existing conventional method to measure contact angle is by means of a contact angle (CA)-Goniometer device, which is less practically applicable in clinical circumstances. Therefore, a more practical and applicable method is needed to measure contact angle in clinical circumstances. This research was performed to compare between contact angles measured by means of a CA-Goniometer device and a new practical method of drop profile image analysis. In addition, since there were two different formulas that can be used to calculate contact angle value from a drop profile image, then we also need to evaluate which formula is more reliable to be used. Tests were carried out using three composite discs (Clearfill-Kuraray Medical, Inc.) sample and deionised water for different measurement procedures. One drop of 3µl liquid was dropped onto the surface of the composite discs, and the drop profile image was captured by means of a customized home-made device connected to a digital camera. Two different formulas were used to calculate the contact angle value from the drop profile image, namely the “linier gradient equation” and the “tangential line”. The contact angle values obtained from the two different formulas were compared with the value obtained from the conventional method descriptively. Tests were carried out using three composite discs (Clearfill-Kuraray Medical, Inc.) sample and deionised water for different measurement procedures. One drop of 3µl liquid was dropped onto the surface of the composite discs, and the drop profile image was captured by means of a customized home-made device connected to a digital camera. Two different formulas were used to calculate the contact angle value from the drop profile image, namely the “linier gradient equation” and the “tangential line”. The contact angle values obtained from the two different formulas were compared with the value obtained from the conventional method descriptively. The differences in percentage between the contact angle value calculated by the “linier gradient equation” and “tangential line” formulas, and those calculated by means of the CA-Goniometer are 20,56% and 3,51%, respectively. It is obviously demonstrated that the value obtained by the “tangential line” formula has a smaller difference compared to those obtained by the “linier equation gradient” formula. Among the two different formulas, it is confirmed that the contact angle value calculated with the “tangential line” formula has closer similarity with the value obtained from the CA-Goniometer. This result confirms that the new practical method of drop profile image analysis is promising for measuring contact angle values in clinical circumstances. Related to the drop profile image analysis, the “tangential line” formula is more accurate compared to the “linier gradient equation” formula.
topic Contact angle, Microbial adhesion, Dentalrestorative materials
url https://jurnal.ugm.ac.id/teknosains/article/view/6023
work_keys_str_mv AT hdkyuliantodanmrinastiti contactanglemeasurementofdentalrestorativematerialsbydropprofileimageanalysis
_version_ 1716740029395501056