Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina

INTRODUCTION: Disinfection of dentin surfaces is desirable so long as it does not interfere with subsequent bonding of adhesive resins. OBJECTIVE: To test the null hypothesis that bond strengths to dentin are not affected by previous application of an iodine disinfecting solution. MATERIALS AND METH...

Full description

Bibliographic Details
Main Authors: Nelson Renato Franca Alves da Silva, Christine S. Calamia, Paulo G. Coelho, Marcela Rocha de Oliveira Carrilho, Ricardo Marins de Carvalho, Page Caufield, Van P. Thompson
Format: Article
Language:English
Published: University of São Paulo 2006-12-01
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000600003
id doaj-f134be13d7d3438bb8c80a62fa92086a
record_format Article
spelling doaj-f134be13d7d3438bb8c80a62fa92086a2020-11-25T00:19:19ZengUniversity of São PauloJournal of Applied Oral Science1678-77571678-77652006-12-0114639940410.1590/S1678-77572006000600003Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentinaNelson Renato Franca Alves da SilvaChristine S. CalamiaPaulo G. CoelhoMarcela Rocha de Oliveira CarrilhoRicardo Marins de CarvalhoPage CaufieldVan P. ThompsonINTRODUCTION: Disinfection of dentin surfaces is desirable so long as it does not interfere with subsequent bonding of adhesive resins. OBJECTIVE: To test the null hypothesis that bond strengths to dentin are not affected by previous application of an iodine disinfecting solution. MATERIALS AND METHODS: Twenty-four extracted non-carious molars were selected. Occlusal enamel was removed producing a flat dentin substrate. Test teeth were all treated with 2% Iodine disclosing/disinfecting solution (I2DDS) for 20 sec and rinsed for 20 sec followed by the application of self- or total- etching bonding systems, generating five adhesive groups (n=3): Single Bond; ; Prime & Bond NT; Clearfil SE Bond; Opti-Bond Plus. The control groups (n=3 per adhesive) had no disclosing/disinfectant application prior to adhesive application. A 4-mm thick resin restoration was built up on each tooth for microtensile testing. Statistical analyses between experimental and control groups were performed by student's t-test (alpha= 0.05). RESULTS: In general, experimental groups (previously treated with I2DDS) showed significantly lower bond strength values when compared with their respective controls (p<0.05), except for group Prime &Bond I2 that did not significantly differ from its control (p>0.05). CONCLUSION: Acetone-base adhesive systems seem not to be affected by the application of I2DDS prior to etching and bonding procedures.<br>INTRODUÇÃO: A desinfecção das superfícies de dentina é desejada desde que não haja interferência na adesão dos agentes adesivos. OBJETIVO: Testar a hipótese nula de que a resistência adesiva não é afetada pela aplicação prévia de uma solução desinfetante de iodo. MATERIAL AND MÉTODO: Vinte e quatro molares hígidos foram selecionados. O esmalte oclusal destes dentes foi removido, e sobre as superfícies planas de dentina expostas foi aplicada da solução desinfetante de Iodo a 2% (I2DDS), que permaneceu sobre a superfície por 20 s e foi lavada por 20 s com água deionizada. Sobre as superfícies desinfetadas foram aplicados um dos seguintes sistemas adesivos (n=3): Single Bond; Prime & Bond NT; Clearfil SE Bond; Opti-Bond Plus. Os grupos controle (n=3) não tiveram a supeficie de dentina tratada com I2DDS antes dos precedimentos adesivos. Em todos os grupos, após hibridização da dentina, foi construída uma "restauração" de resina composta com cerca de 4 mm de espessura. Após 7 dias de armazenagem em água destilada, os dentes foram secionados de modo a originarem espécimes a serem submetidos ao teste de microtração (palitos). Análise estatística para comparação dos dados foi realizada pelo teste t de student (alfa=0,05). RESULTADOS: De forma geral, os grupos experimentais (tratados com I2DDS) apresentraram resistência adesiva significativamente menor do que os respectivos grupos controle (p<0.05), exceção se fez apenas para o grupo P&BI2, que não diferiu significativamente de seu grupo controle P&BC (p>0.05). Assim, a hipótese nula deve ser rejeitada para os adesivos a base de etanol e/ou a base de água, mas aceita para o adesivo a base de acetona. CONCLUSÃO: O uso da solução experimental de iodo previamente à realização dos procedimentos adesivos afetou a efetividade da união à dentina apenas quando do emprego de sistemas adesivos a base de etanol e/ou água.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000600003DentinaAdesivos dentináriosIodoSensibilidade dentináriaDentinDentin-bonding agentsIodineDentin sensitivity
collection DOAJ
language English
format Article
sources DOAJ
author Nelson Renato Franca Alves da Silva
Christine S. Calamia
Paulo G. Coelho
Marcela Rocha de Oliveira Carrilho
Ricardo Marins de Carvalho
Page Caufield
Van P. Thompson
spellingShingle Nelson Renato Franca Alves da Silva
Christine S. Calamia
Paulo G. Coelho
Marcela Rocha de Oliveira Carrilho
Ricardo Marins de Carvalho
Page Caufield
Van P. Thompson
Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina
Journal of Applied Oral Science
Dentina
Adesivos dentinários
Iodo
Sensibilidade dentinária
Dentin
Dentin-bonding agents
Iodine
Dentin sensitivity
author_facet Nelson Renato Franca Alves da Silva
Christine S. Calamia
Paulo G. Coelho
Marcela Rocha de Oliveira Carrilho
Ricardo Marins de Carvalho
Page Caufield
Van P. Thompson
author_sort Nelson Renato Franca Alves da Silva
title Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina
title_short Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina
title_full Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina
title_fullStr Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina
title_full_unstemmed Effect of 2% iodine disinfecting solution on bond strength to dentin Efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina
title_sort effect of 2% iodine disinfecting solution on bond strength to dentin efeito da solução desinfetante de iodo a 2% sobre a adesão à dentina
publisher University of São Paulo
series Journal of Applied Oral Science
issn 1678-7757
1678-7765
publishDate 2006-12-01
description INTRODUCTION: Disinfection of dentin surfaces is desirable so long as it does not interfere with subsequent bonding of adhesive resins. OBJECTIVE: To test the null hypothesis that bond strengths to dentin are not affected by previous application of an iodine disinfecting solution. MATERIALS AND METHODS: Twenty-four extracted non-carious molars were selected. Occlusal enamel was removed producing a flat dentin substrate. Test teeth were all treated with 2% Iodine disclosing/disinfecting solution (I2DDS) for 20 sec and rinsed for 20 sec followed by the application of self- or total- etching bonding systems, generating five adhesive groups (n=3): Single Bond; ; Prime & Bond NT; Clearfil SE Bond; Opti-Bond Plus. The control groups (n=3 per adhesive) had no disclosing/disinfectant application prior to adhesive application. A 4-mm thick resin restoration was built up on each tooth for microtensile testing. Statistical analyses between experimental and control groups were performed by student's t-test (alpha= 0.05). RESULTS: In general, experimental groups (previously treated with I2DDS) showed significantly lower bond strength values when compared with their respective controls (p<0.05), except for group Prime &Bond I2 that did not significantly differ from its control (p>0.05). CONCLUSION: Acetone-base adhesive systems seem not to be affected by the application of I2DDS prior to etching and bonding procedures.<br>INTRODUÇÃO: A desinfecção das superfícies de dentina é desejada desde que não haja interferência na adesão dos agentes adesivos. OBJETIVO: Testar a hipótese nula de que a resistência adesiva não é afetada pela aplicação prévia de uma solução desinfetante de iodo. MATERIAL AND MÉTODO: Vinte e quatro molares hígidos foram selecionados. O esmalte oclusal destes dentes foi removido, e sobre as superfícies planas de dentina expostas foi aplicada da solução desinfetante de Iodo a 2% (I2DDS), que permaneceu sobre a superfície por 20 s e foi lavada por 20 s com água deionizada. Sobre as superfícies desinfetadas foram aplicados um dos seguintes sistemas adesivos (n=3): Single Bond; Prime & Bond NT; Clearfil SE Bond; Opti-Bond Plus. Os grupos controle (n=3) não tiveram a supeficie de dentina tratada com I2DDS antes dos precedimentos adesivos. Em todos os grupos, após hibridização da dentina, foi construída uma "restauração" de resina composta com cerca de 4 mm de espessura. Após 7 dias de armazenagem em água destilada, os dentes foram secionados de modo a originarem espécimes a serem submetidos ao teste de microtração (palitos). Análise estatística para comparação dos dados foi realizada pelo teste t de student (alfa=0,05). RESULTADOS: De forma geral, os grupos experimentais (tratados com I2DDS) apresentraram resistência adesiva significativamente menor do que os respectivos grupos controle (p<0.05), exceção se fez apenas para o grupo P&BI2, que não diferiu significativamente de seu grupo controle P&BC (p>0.05). Assim, a hipótese nula deve ser rejeitada para os adesivos a base de etanol e/ou a base de água, mas aceita para o adesivo a base de acetona. CONCLUSÃO: O uso da solução experimental de iodo previamente à realização dos procedimentos adesivos afetou a efetividade da união à dentina apenas quando do emprego de sistemas adesivos a base de etanol e/ou água.
topic Dentina
Adesivos dentinários
Iodo
Sensibilidade dentinária
Dentin
Dentin-bonding agents
Iodine
Dentin sensitivity
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000600003
work_keys_str_mv AT nelsonrenatofrancaalvesdasilva effectof2iodinedisinfectingsolutiononbondstrengthtodentinefeitodasolucaodesinfetantedeiodoa2sobreaadesaoadentina
AT christinescalamia effectof2iodinedisinfectingsolutiononbondstrengthtodentinefeitodasolucaodesinfetantedeiodoa2sobreaadesaoadentina
AT paulogcoelho effectof2iodinedisinfectingsolutiononbondstrengthtodentinefeitodasolucaodesinfetantedeiodoa2sobreaadesaoadentina
AT marcelarochadeoliveiracarrilho effectof2iodinedisinfectingsolutiononbondstrengthtodentinefeitodasolucaodesinfetantedeiodoa2sobreaadesaoadentina
AT ricardomarinsdecarvalho effectof2iodinedisinfectingsolutiononbondstrengthtodentinefeitodasolucaodesinfetantedeiodoa2sobreaadesaoadentina
AT pagecaufield effectof2iodinedisinfectingsolutiononbondstrengthtodentinefeitodasolucaodesinfetantedeiodoa2sobreaadesaoadentina
AT vanpthompson effectof2iodinedisinfectingsolutiononbondstrengthtodentinefeitodasolucaodesinfetantedeiodoa2sobreaadesaoadentina
_version_ 1725372099274473472