Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal Phonocardiography

Fetal phonocardiography (fPCG) is a non-invasive technique for detection of fetal heart sounds (fHSs), murmurs and vibrations. This acoustic recording is passive and provides an alternative low-cost method to ultrasonographic cardiotocography (CTG). Unfortunately, the fPCG signal is often disturbed...

Full description

Bibliographic Details
Main Authors: Radek Martinek, Katerina Barnova, Rene Jaros, Radana Kahankova, Tomasz Kupka, Michal Jezewski, Robert Czabanski, Adam Matonia, Janusz Jezewski, Krzysztof Horoba
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9288669/
id doaj-f1b9727455644119a52816a73dfc1f4b
record_format Article
spelling doaj-f1b9727455644119a52816a73dfc1f4b2021-03-30T03:50:55ZengIEEEIEEE Access2169-35362020-01-01822194222196210.1109/ACCESS.2020.30434969288669Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal PhonocardiographyRadek Martinek0https://orcid.org/0000-0003-2054-143XKaterina Barnova1https://orcid.org/0000-0001-5594-8294Rene Jaros2https://orcid.org/0000-0003-3346-6467Radana Kahankova3https://orcid.org/0000-0003-1555-9889Tomasz Kupka4Michal Jezewski5https://orcid.org/0000-0002-6026-0264Robert Czabanski6https://orcid.org/0000-0003-4737-2138Adam Matonia7Janusz Jezewski8Krzysztof Horoba9Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB&#x2014;Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB&#x2014;Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB&#x2014;Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB&#x2014;Technical University of Ostrava, Ostrava, Czech RepublicŁkasiewicz Research Network, Institute of Medical Technology and Equipment, Wroc&#x0142;aw, PolandDepartment of Cybernetics, Nanotechnology, and Data Processing, Silesian University of Technology, Gliwice, PolandDepartment of Cybernetics, Nanotechnology, and Data Processing, Silesian University of Technology, Gliwice, PolandŁkasiewicz Research Network, Institute of Medical Technology and Equipment, Wroc&#x0142;aw, PolandŁkasiewicz Research Network, Institute of Medical Technology and Equipment, Wroc&#x0142;aw, PolandŁkasiewicz Research Network, Institute of Medical Technology and Equipment, Wroc&#x0142;aw, PolandFetal phonocardiography (fPCG) is a non-invasive technique for detection of fetal heart sounds (fHSs), murmurs and vibrations. This acoustic recording is passive and provides an alternative low-cost method to ultrasonographic cardiotocography (CTG). Unfortunately, the fPCG signal is often disturbed by the wide range of artifacts that make it difficult to obtain significant diagnostic information from this signal. The study focuses on the filtering of an fPCG signal containing three types of noise (ambient noise, Gaussian noise, and movement artifacts of the mother and the fetus) having different amplitudes. Three advanced signal processing methods: empirical mode decomposition (EMD), ensemble empirical mode decomposition (EEMD), and adaptive wavelet transform (AWT) were tested and compared. The evaluation of the extraction was performed by determining the accuracy of S1 sounds detection and by determining the fetal heart rate (fHR). The evaluation of the effectiveness of the method was performed using signal-to-noise ratio (SNR), mean error of heart interval measurement (|&#x0394;T<sub>i</sub>| ), and the statistical parameters of accuracy (ACC), sensitivity (SE), positive predictive value (PPV), and harmonic mean between SE and PPV (F1). Using the EMD method, ACC &gt; 95$ % was achieved in 7 out of 12 types and levels of interference with average values of ACC = 88.73 %, SE = 91.57 %, PPV = 94.80 % and $\text {F1} = 93.12$ %. Using the EEMD method, ACC &gt; 95$ % was achieved in 9 out of 12 types and levels of interference with average values of ACC = 97.49 %, SE = 97.89 %, PV = 99.53 % and F1 = 98.69 %. In this study, the best results were achieved using the AWT method, which provided ACC &gt; 95 % in all 12 types and levels of interference with average values of ACC = 99.34 %, SE = 99.49 %, PPV = 99.85 % a F1 = 99.67 %.https://ieeexplore.ieee.org/document/9288669/Fetal phonocardiography (fPCG)fetal heart rate (fHR)non-invasive fetal monitoringempirical mode decomposition (EMD)ensemble empirical mode decomposition (EEMD)adaptive wavelet transform (AWT)
collection DOAJ
language English
format Article
sources DOAJ
author Radek Martinek
Katerina Barnova
Rene Jaros
Radana Kahankova
Tomasz Kupka
Michal Jezewski
Robert Czabanski
Adam Matonia
Janusz Jezewski
Krzysztof Horoba
spellingShingle Radek Martinek
Katerina Barnova
Rene Jaros
Radana Kahankova
Tomasz Kupka
Michal Jezewski
Robert Czabanski
Adam Matonia
Janusz Jezewski
Krzysztof Horoba
Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal Phonocardiography
IEEE Access
Fetal phonocardiography (fPCG)
fetal heart rate (fHR)
non-invasive fetal monitoring
empirical mode decomposition (EMD)
ensemble empirical mode decomposition (EEMD)
adaptive wavelet transform (AWT)
author_facet Radek Martinek
Katerina Barnova
Rene Jaros
Radana Kahankova
Tomasz Kupka
Michal Jezewski
Robert Czabanski
Adam Matonia
Janusz Jezewski
Krzysztof Horoba
author_sort Radek Martinek
title Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal Phonocardiography
title_short Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal Phonocardiography
title_full Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal Phonocardiography
title_fullStr Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal Phonocardiography
title_full_unstemmed Passive Fetal Monitoring by Advanced Signal Processing Methods in Fetal Phonocardiography
title_sort passive fetal monitoring by advanced signal processing methods in fetal phonocardiography
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2020-01-01
description Fetal phonocardiography (fPCG) is a non-invasive technique for detection of fetal heart sounds (fHSs), murmurs and vibrations. This acoustic recording is passive and provides an alternative low-cost method to ultrasonographic cardiotocography (CTG). Unfortunately, the fPCG signal is often disturbed by the wide range of artifacts that make it difficult to obtain significant diagnostic information from this signal. The study focuses on the filtering of an fPCG signal containing three types of noise (ambient noise, Gaussian noise, and movement artifacts of the mother and the fetus) having different amplitudes. Three advanced signal processing methods: empirical mode decomposition (EMD), ensemble empirical mode decomposition (EEMD), and adaptive wavelet transform (AWT) were tested and compared. The evaluation of the extraction was performed by determining the accuracy of S1 sounds detection and by determining the fetal heart rate (fHR). The evaluation of the effectiveness of the method was performed using signal-to-noise ratio (SNR), mean error of heart interval measurement (|&#x0394;T<sub>i</sub>| ), and the statistical parameters of accuracy (ACC), sensitivity (SE), positive predictive value (PPV), and harmonic mean between SE and PPV (F1). Using the EMD method, ACC &gt; 95$ % was achieved in 7 out of 12 types and levels of interference with average values of ACC = 88.73 %, SE = 91.57 %, PPV = 94.80 % and $\text {F1} = 93.12$ %. Using the EEMD method, ACC &gt; 95$ % was achieved in 9 out of 12 types and levels of interference with average values of ACC = 97.49 %, SE = 97.89 %, PV = 99.53 % and F1 = 98.69 %. In this study, the best results were achieved using the AWT method, which provided ACC &gt; 95 % in all 12 types and levels of interference with average values of ACC = 99.34 %, SE = 99.49 %, PPV = 99.85 % a F1 = 99.67 %.
topic Fetal phonocardiography (fPCG)
fetal heart rate (fHR)
non-invasive fetal monitoring
empirical mode decomposition (EMD)
ensemble empirical mode decomposition (EEMD)
adaptive wavelet transform (AWT)
url https://ieeexplore.ieee.org/document/9288669/
work_keys_str_mv AT radekmartinek passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT katerinabarnova passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT renejaros passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT radanakahankova passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT tomaszkupka passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT michaljezewski passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT robertczabanski passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT adammatonia passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT januszjezewski passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
AT krzysztofhoroba passivefetalmonitoringbyadvancedsignalprocessingmethodsinfetalphonocardiography
_version_ 1724182795634343936