23-valent polysaccharide vaccine (PPSV23)-targeted serotype-specific identification of Streptococcus pneumoniae using the loop-mediated isothermal amplification (LAMP) method.

Reports of invasive disease due to Streptococcus pneumoniae have declined since the introduction of pneumococcal conjugate vaccines (PCV7 and PCV13). The incidence of invasive diseases due to S. pneumoniae that are not addressed by the vaccines, however, has increased in children and adults, creatin...

Full description

Bibliographic Details
Main Authors: Jiwon Lee, Youngbae Yoon, Eun Jin Kim, Donghyun Lee, Yeongjun Baek, Chika Takano, Bin Chang, Takahiro Iijima, Paul E Kilgore, Satoshi Hayakawa, Tomonori Hoshino, Dong Wook Kim, Mitsuko Seki
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2021-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0246699
Description
Summary:Reports of invasive disease due to Streptococcus pneumoniae have declined since the introduction of pneumococcal conjugate vaccines (PCV7 and PCV13). The incidence of invasive diseases due to S. pneumoniae that are not addressed by the vaccines, however, has increased in children and adults, creating a global public health problem. Previously, we established the loop-mediated isothermal amplification (LAMP) method for a PCV13 serotype-specific assay. In the current study, we developed a rapid, simple, and cost-effective assay to detect serotypes in the 23-valent pneumococcal polysaccharide vaccine (PPSV23) using the LAMP method. In this study, LAMP primer sets for serotypes 2, 8, 9N, 10A, 11A, 12F, 15B, 17F, 20, 22F, and 33F of S. pneumoniae were developed. The reactivity, specificity, and sensitivity of LAMP assays were determined and compared to those of conventional PCR. The feasibility of LAMP assays in clinical application in patients with invasive pneumococcal diseases was validated by defining the detection limit of the LAMP assay with bacterial genomic DNA-spiked blood specimens. The specificity of each LAMP assay was determined using 44 serotypes of pneumococcal strains. Their sensitivity was 100 copies per reaction versus 103 to 106 copies per reaction for PCR assays. Using DNA-spiked blood specimens, excluding the LAMP assay that targeted serotype 22F (103 copies per reaction), the limit of detection of the LAMP assay was similar to that with purified DNA as the template (102 copies per reaction), compared with 103 to >106 copies per reaction for PCR assays. In conclusion, a rapid and simple LAMP-based PPSV23-targeted serotype detection assay was developed for use in many countries. This study is the first report of a LAMP-based assay for identification of PPSV23 serotypes. Further evaluation of this assay is needed through surveillance and vaccine efficacy studies.
ISSN:1932-6203