Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft

OBJETIVO: Avaliação radiográfica do alinhamento do membro inferior, nos planos frontal e sagital, após osteotomia alta da tíbia. Para estabilização da osteotomia foi utilizado enxerto tricortical de ilíaco e parafuso de posicionamento. MÉTODOS: Estudo prospectivo envolvendo 46 pacientes com idade en...

Full description

Bibliographic Details
Main Authors: Roberto da Cunha Luciano, Getúlio Danival de Moura Souza, Juliano Rispoli, Rodrigo Galvão Cardoso, Marcus Vinícius Martins do Nascimento, Gustavo Gontijo Domingos, Dyego Vilela Luciano
Format: Article
Language:English
Published: Sociedade Brasileira de Ortopedia e Traumatologia 2010-01-01
Series:Revista Brasileira de Ortopedia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162010000600006
id doaj-f4a8ae427b8d4258899a709c65b4a451
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Roberto da Cunha Luciano
Getúlio Danival de Moura Souza
Juliano Rispoli
Rodrigo Galvão Cardoso
Marcus Vinícius Martins do Nascimento
Gustavo Gontijo Domingos
Dyego Vilela Luciano
spellingShingle Roberto da Cunha Luciano
Getúlio Danival de Moura Souza
Juliano Rispoli
Rodrigo Galvão Cardoso
Marcus Vinícius Martins do Nascimento
Gustavo Gontijo Domingos
Dyego Vilela Luciano
Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft
Revista Brasileira de Ortopedia
Osteotomia
Joelho
Osteoartrite
Tíbia
Osteotomy
Knee
Osteoarthritis
Tibia
author_facet Roberto da Cunha Luciano
Getúlio Danival de Moura Souza
Juliano Rispoli
Rodrigo Galvão Cardoso
Marcus Vinícius Martins do Nascimento
Gustavo Gontijo Domingos
Dyego Vilela Luciano
author_sort Roberto da Cunha Luciano
title Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft
title_short Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft
title_full Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft
title_fullStr Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft
title_full_unstemmed Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft
title_sort osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graft
publisher Sociedade Brasileira de Ortopedia e Traumatologia
series Revista Brasileira de Ortopedia
issn 0102-3616
1982-4378
publishDate 2010-01-01
description OBJETIVO: Avaliação radiográfica do alinhamento do membro inferior, nos planos frontal e sagital, após osteotomia alta da tíbia. Para estabilização da osteotomia foi utilizado enxerto tricortical de ilíaco e parafuso de posicionamento. MÉTODOS: Estudo prospectivo envolvendo 46 pacientes com idade entre 17 e 61 anos, sendo 42 portadores de geno varo secundário à osteoartrose e quatro por outras causas. A telerradiografia foi realizada para planejamento cirúrgico, utilizando o método de Frank Noyes modificado por Fugizawa. Foi realizado acesso cirúrgico convencional de 3cm para retirada do enxerto tricortical de ilíaco. A osteotomia foi realizada sob controle de radioscopia, por incisão anteromedial de 3cm com liberação da porção superficial do ligamento colateral medial. O enxerto foi colocado na porção posterior da osteotomia, para manter inalterado o slope tibial. O parafuso cruzou a osteotomia ortogonalmente para proteger a cortical lateral. Foram estabelecidos critérios radiográficos pré e pós-operatórios para avaliação dos resultados. RESULTADOS: Houve consolidação em 100% dos casos e manutenção do eixo mecânico, obtido no intraoperatório, em 94%. A inclinação posterior do platô tibial, no plano sagital, variou entre 7º e 12º. A mobilidade articular foi restabelecida em todos os pacientes operados. Onze pacientes apresentaram dor temporária no local da retirada do enxerto; no entanto, nenhum apresentou parestesia. A incidência de complicações foi de 8% (infecção, perda da correção, fratura articular). CONCLUSÃO: A técnica mostrou-se reprodutível, simples, biológica, precisa e com baixos custos, podendo ser uma alternativa às técnicas já existentes.<br>OBJECTIVE: Roentgenographic assessment of lower limb alignment, in the frontal and sagittal planes, after a high tibial osteotomy. To stabilize the osteotomy, a tricortical iliac graft was used along with a positioning screw. METHODS: Prospective study of 46 patients with ages ranging from 17 to 61 years. Among them, 42 patients were carriers of genu varum secondary to knee osteoarthritis and four from other causes. Radiography was performed for surgical planning, using the Frank Noyes method modified by Fugizawa. Three cm conventional surgical access was performed to remove a tricortical iliac graft. The osteotomy was performed under fluoroscopic control, by 3 cm anteromedial incision with release of the superficial portion of the medial collateral ligament. The graft was placed in the posterior portion of the osteotomy to maintain an unaltered tibial slope. The screw crossed the osteotomy orthogonally to protect the lateral cortex. Radiographic criteria were established pre-and postoperatively to assess the results. RESULTS: There was consolidation in 100% of cases and maintenance of the mechanical axis, obtained intraoperatively in 94% of cases. Correction of mechanical axis occurred in 94% (43 patients / 47 osteotomies). The posterior slope of the tibial plateau in the sagittal plane ranged from 7º to 12º. Joint mobility was restored in all patients. Eleven patients had temporary pain at the site of graft removal, however, none had paraesthesia. The incidence of complications was 8% (infection, loss of correction, joint fracture). CONCLUSION: This technique is reproducible, simple, biologic, accurate, low-cost, and can be used as an alternative to existing techniques.
topic Osteotomia
Joelho
Osteoartrite
Tíbia
Osteotomy
Knee
Osteoarthritis
Tibia
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162010000600006
work_keys_str_mv AT robertodacunhaluciano osteotomiaproximaldatibiaestabilizacaodaaberturamedialcomenxertotricorticaldeiliacoproximaltibialosteotomystabilizationofthemedialopeningwithatricorticaliliacbonegraft
AT getuliodanivaldemourasouza osteotomiaproximaldatibiaestabilizacaodaaberturamedialcomenxertotricorticaldeiliacoproximaltibialosteotomystabilizationofthemedialopeningwithatricorticaliliacbonegraft
AT julianorispoli osteotomiaproximaldatibiaestabilizacaodaaberturamedialcomenxertotricorticaldeiliacoproximaltibialosteotomystabilizationofthemedialopeningwithatricorticaliliacbonegraft
AT rodrigogalvaocardoso osteotomiaproximaldatibiaestabilizacaodaaberturamedialcomenxertotricorticaldeiliacoproximaltibialosteotomystabilizationofthemedialopeningwithatricorticaliliacbonegraft
AT marcusviniciusmartinsdonascimento osteotomiaproximaldatibiaestabilizacaodaaberturamedialcomenxertotricorticaldeiliacoproximaltibialosteotomystabilizationofthemedialopeningwithatricorticaliliacbonegraft
AT gustavogontijodomingos osteotomiaproximaldatibiaestabilizacaodaaberturamedialcomenxertotricorticaldeiliacoproximaltibialosteotomystabilizationofthemedialopeningwithatricorticaliliacbonegraft
AT dyegovilelaluciano osteotomiaproximaldatibiaestabilizacaodaaberturamedialcomenxertotricorticaldeiliacoproximaltibialosteotomystabilizationofthemedialopeningwithatricorticaliliacbonegraft
_version_ 1725648802031861760
spelling doaj-f4a8ae427b8d4258899a709c65b4a4512020-11-24T22:58:00ZengSociedade Brasileira de Ortopedia e TraumatologiaRevista Brasileira de Ortopedia0102-36161982-43782010-01-0145654354810.1590/S0102-36162010000600006Osteotomia proximal da tíbia: estabilização da abertura medial com enxerto tricortical de ilíaco Proximal tibial osteotomy: stabilization of the medial opening with atricortical iliac bone graftRoberto da Cunha LucianoGetúlio Danival de Moura SouzaJuliano RispoliRodrigo Galvão CardosoMarcus Vinícius Martins do NascimentoGustavo Gontijo DomingosDyego Vilela LucianoOBJETIVO: Avaliação radiográfica do alinhamento do membro inferior, nos planos frontal e sagital, após osteotomia alta da tíbia. Para estabilização da osteotomia foi utilizado enxerto tricortical de ilíaco e parafuso de posicionamento. MÉTODOS: Estudo prospectivo envolvendo 46 pacientes com idade entre 17 e 61 anos, sendo 42 portadores de geno varo secundário à osteoartrose e quatro por outras causas. A telerradiografia foi realizada para planejamento cirúrgico, utilizando o método de Frank Noyes modificado por Fugizawa. Foi realizado acesso cirúrgico convencional de 3cm para retirada do enxerto tricortical de ilíaco. A osteotomia foi realizada sob controle de radioscopia, por incisão anteromedial de 3cm com liberação da porção superficial do ligamento colateral medial. O enxerto foi colocado na porção posterior da osteotomia, para manter inalterado o slope tibial. O parafuso cruzou a osteotomia ortogonalmente para proteger a cortical lateral. Foram estabelecidos critérios radiográficos pré e pós-operatórios para avaliação dos resultados. RESULTADOS: Houve consolidação em 100% dos casos e manutenção do eixo mecânico, obtido no intraoperatório, em 94%. A inclinação posterior do platô tibial, no plano sagital, variou entre 7º e 12º. A mobilidade articular foi restabelecida em todos os pacientes operados. Onze pacientes apresentaram dor temporária no local da retirada do enxerto; no entanto, nenhum apresentou parestesia. A incidência de complicações foi de 8% (infecção, perda da correção, fratura articular). CONCLUSÃO: A técnica mostrou-se reprodutível, simples, biológica, precisa e com baixos custos, podendo ser uma alternativa às técnicas já existentes.<br>OBJECTIVE: Roentgenographic assessment of lower limb alignment, in the frontal and sagittal planes, after a high tibial osteotomy. To stabilize the osteotomy, a tricortical iliac graft was used along with a positioning screw. METHODS: Prospective study of 46 patients with ages ranging from 17 to 61 years. Among them, 42 patients were carriers of genu varum secondary to knee osteoarthritis and four from other causes. Radiography was performed for surgical planning, using the Frank Noyes method modified by Fugizawa. Three cm conventional surgical access was performed to remove a tricortical iliac graft. The osteotomy was performed under fluoroscopic control, by 3 cm anteromedial incision with release of the superficial portion of the medial collateral ligament. The graft was placed in the posterior portion of the osteotomy to maintain an unaltered tibial slope. The screw crossed the osteotomy orthogonally to protect the lateral cortex. Radiographic criteria were established pre-and postoperatively to assess the results. RESULTS: There was consolidation in 100% of cases and maintenance of the mechanical axis, obtained intraoperatively in 94% of cases. Correction of mechanical axis occurred in 94% (43 patients / 47 osteotomies). The posterior slope of the tibial plateau in the sagittal plane ranged from 7º to 12º. Joint mobility was restored in all patients. Eleven patients had temporary pain at the site of graft removal, however, none had paraesthesia. The incidence of complications was 8% (infection, loss of correction, joint fracture). CONCLUSION: This technique is reproducible, simple, biologic, accurate, low-cost, and can be used as an alternative to existing techniques.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162010000600006OsteotomiaJoelhoOsteoartriteTíbiaOsteotomyKneeOsteoarthritisTibia