Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column

A flow injection chemiluminescence immunoassay for rapid and sensitive detection of carcinoembryonic antigen (CEA) by using a phenylboronic acid-based immunoaffinity column as a glycoprotein collector was proposed in this paper. The column was prepared by coupling of 3-aminophenylboronic acid on the...

Full description

Bibliographic Details
Main Authors: Xiaodi Yang, Chong Sun, Laifa Li, Min Wu, Xiaoling Ma, Huihui Li
Format: Article
Language:English
Published: MDPI AG 2009-12-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/9/12/10389/
id doaj-f4d557dad2f74e7c83bf4857e6dfd3ca
record_format Article
spelling doaj-f4d557dad2f74e7c83bf4857e6dfd3ca2020-11-25T00:14:39ZengMDPI AGSensors1424-82202009-12-01912103891039910.3390/s91210389Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity ColumnXiaodi YangChong SunLaifa LiMin WuXiaoling MaHuihui LiA flow injection chemiluminescence immunoassay for rapid and sensitive detection of carcinoembryonic antigen (CEA) by using a phenylboronic acid-based immunoaffinity column as a glycoprotein collector was proposed in this paper. The column was prepared by coupling of 3-aminophenylboronic acid on the glass beads through a γ-glycidoxypropyltrimethoxysilane (GPMS) linkage. Based on an indirect competitive immunoreaction, the mixture of CEA sample and enzyme conjugated CEA antibody (HRP-anti-CEA) was incubated in advance, followed by direct injection to the column to capture free HRP-labeled CEA antibody in the column. The trapped HRP-labeled antibody was detected by flow inject chemiluminescence in the presence of luminol and hydrogen peroxide. The decreased chemiluminescent signal was proportional to the concentration of CEA in the range of 3.0–30.0 ng/mL with a correlation coefficient of 0.998. The column showed an acceptable reproducibility and stability and is potentially used for practical clinical detection of the serum CEA level. http://www.mdpi.com/1424-8220/9/12/10389/flow injection chemiluminescence immunoassaycarcinoembryonic antigenboronic immunoaffinity column
collection DOAJ
language English
format Article
sources DOAJ
author Xiaodi Yang
Chong Sun
Laifa Li
Min Wu
Xiaoling Ma
Huihui Li
spellingShingle Xiaodi Yang
Chong Sun
Laifa Li
Min Wu
Xiaoling Ma
Huihui Li
Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
Sensors
flow injection chemiluminescence immunoassay
carcinoembryonic antigen
boronic immunoaffinity column
author_facet Xiaodi Yang
Chong Sun
Laifa Li
Min Wu
Xiaoling Ma
Huihui Li
author_sort Xiaodi Yang
title Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_short Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_full Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_fullStr Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_full_unstemmed Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_sort flow injection chemiluminescent immunoassay for carcinoembryonic antigen using boronic immunoaffinity column
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2009-12-01
description A flow injection chemiluminescence immunoassay for rapid and sensitive detection of carcinoembryonic antigen (CEA) by using a phenylboronic acid-based immunoaffinity column as a glycoprotein collector was proposed in this paper. The column was prepared by coupling of 3-aminophenylboronic acid on the glass beads through a γ-glycidoxypropyltrimethoxysilane (GPMS) linkage. Based on an indirect competitive immunoreaction, the mixture of CEA sample and enzyme conjugated CEA antibody (HRP-anti-CEA) was incubated in advance, followed by direct injection to the column to capture free HRP-labeled CEA antibody in the column. The trapped HRP-labeled antibody was detected by flow inject chemiluminescence in the presence of luminol and hydrogen peroxide. The decreased chemiluminescent signal was proportional to the concentration of CEA in the range of 3.0–30.0 ng/mL with a correlation coefficient of 0.998. The column showed an acceptable reproducibility and stability and is potentially used for practical clinical detection of the serum CEA level.
topic flow injection chemiluminescence immunoassay
carcinoembryonic antigen
boronic immunoaffinity column
url http://www.mdpi.com/1424-8220/9/12/10389/
work_keys_str_mv AT xiaodiyang flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT chongsun flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT laifali flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT minwu flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT xiaolingma flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT huihuili flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
_version_ 1725389361216749568