The effectiveness of facade systems

The article discusses the results of studying the thermotechnical properties and energy saving factors of insulation systems based on mineral wool products and products based on extruded polystyrene foam under conditions close to natural ones. The studies were carried out on the basis of the hypothe...

Full description

Bibliographic Details
Main Authors: Umnyakova Nina, Bessonov Igor, Zhukov Alex, Zinoveva Ekaterina
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2019/47/matecconf_icmtmte18_00013.pdf
id doaj-f5ed2d285524444992fc3fdd92a0831b
record_format Article
spelling doaj-f5ed2d285524444992fc3fdd92a0831b2021-04-02T13:33:36ZengEDP SciencesMATEC Web of Conferences2261-236X2019-01-012980001310.1051/matecconf/201929800013matecconf_icmtmte18_00013The effectiveness of facade systemsUmnyakova Nina0Bessonov Igor1Zhukov Alex2Zinoveva Ekaterina3NIISF RAASNNIISF RAASNNRU MGSUNRU MGSUThe article discusses the results of studying the thermotechnical properties and energy saving factors of insulation systems based on mineral wool products and products based on extruded polystyrene foam under conditions close to natural ones. The studies were carried out on the basis of the hypothesis according to which the heat-saving characteristics of the facade insulation systems are most dependent on the thermal resistance along the surface of the wall, on the thermotechnical uniformity of the insulating sheath and on the stability of the properties of the heat-insulating materials under real operating conditions. The implemented complex made it possible to establish that the smallest difference between the air temperature in the room and the surface temperature in the lower zone was achieved on a fragment of the building envelope with a mounted facade system with XPS as insulation. For the same type of facade system, the maximum heat transfer resistance in the lower zone of the building envelope was reached - 2.72 m2 ° C / W for the cold period of the year, which significantly exceeds the characteristics of the system of mounted ventilated facades with mineral wool thermal insulation in the corresponding zones. The factor of “additional warming” from the soil, which is used to justify the rejection of warming in the buried part of the structure, does not work in the cold season. Flooding at thezone with the junction of the wall with the soil significantly affects the values and nature of the distribution of operating humidity inside the insulation layers.https://www.matec-conferences.org/articles/matecconf/pdf/2019/47/matecconf_icmtmte18_00013.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Umnyakova Nina
Bessonov Igor
Zhukov Alex
Zinoveva Ekaterina
spellingShingle Umnyakova Nina
Bessonov Igor
Zhukov Alex
Zinoveva Ekaterina
The effectiveness of facade systems
MATEC Web of Conferences
author_facet Umnyakova Nina
Bessonov Igor
Zhukov Alex
Zinoveva Ekaterina
author_sort Umnyakova Nina
title The effectiveness of facade systems
title_short The effectiveness of facade systems
title_full The effectiveness of facade systems
title_fullStr The effectiveness of facade systems
title_full_unstemmed The effectiveness of facade systems
title_sort effectiveness of facade systems
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2019-01-01
description The article discusses the results of studying the thermotechnical properties and energy saving factors of insulation systems based on mineral wool products and products based on extruded polystyrene foam under conditions close to natural ones. The studies were carried out on the basis of the hypothesis according to which the heat-saving characteristics of the facade insulation systems are most dependent on the thermal resistance along the surface of the wall, on the thermotechnical uniformity of the insulating sheath and on the stability of the properties of the heat-insulating materials under real operating conditions. The implemented complex made it possible to establish that the smallest difference between the air temperature in the room and the surface temperature in the lower zone was achieved on a fragment of the building envelope with a mounted facade system with XPS as insulation. For the same type of facade system, the maximum heat transfer resistance in the lower zone of the building envelope was reached - 2.72 m2 ° C / W for the cold period of the year, which significantly exceeds the characteristics of the system of mounted ventilated facades with mineral wool thermal insulation in the corresponding zones. The factor of “additional warming” from the soil, which is used to justify the rejection of warming in the buried part of the structure, does not work in the cold season. Flooding at thezone with the junction of the wall with the soil significantly affects the values and nature of the distribution of operating humidity inside the insulation layers.
url https://www.matec-conferences.org/articles/matecconf/pdf/2019/47/matecconf_icmtmte18_00013.pdf
work_keys_str_mv AT umnyakovanina theeffectivenessoffacadesystems
AT bessonovigor theeffectivenessoffacadesystems
AT zhukovalex theeffectivenessoffacadesystems
AT zinovevaekaterina theeffectivenessoffacadesystems
AT umnyakovanina effectivenessoffacadesystems
AT bessonovigor effectivenessoffacadesystems
AT zhukovalex effectivenessoffacadesystems
AT zinovevaekaterina effectivenessoffacadesystems
_version_ 1721564649332146176