Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes

Suzuki Indomobil Motor Plant (SIMP) Cakung, East Jakarta, Indonesia generates wastewater containing heavy metals such as nickel, zinc, chromium, copper, and COD derived from the metal coating process using the electroplating system. Electroplating wastewater produced by this company contains Nickel...

Full description

Bibliographic Details
Main Authors: Setyo Sarwanto Moersidik, Rudi Nugroho, Mira Handayani, Kamilawati, Mochamad A. Pratama
Format: Article
Language:English
Published: Elsevier 2020-02-01
Series:Heliyon
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S240584402030164X
id doaj-fb12c24e44094b369277e2044b6c2d01
record_format Article
spelling doaj-fb12c24e44094b369277e2044b6c2d012020-11-25T03:01:15ZengElsevierHeliyon2405-84402020-02-0162e03319Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation ProcessesSetyo Sarwanto Moersidik0Rudi Nugroho1Mira Handayani2 Kamilawati3Mochamad A. Pratama4Study Program of Civil Engineering-Specialization in Environmental Engineering, Departement of Civil Engineering, Faculty of Engineering, Indonesia University, Depok, 16424, Indonesia; Corresponding author.Pusat Teknologi Lingkungan, Badan Pengkajian dan Penerapan Teknologi, Gedung Geostech Komplek Puspitek, Serpong, Tangerang, IndonesiaStudy Program of Civil Engineering-Specialization in Environmental Engineering, Departement of Civil Engineering, Faculty of Engineering, Indonesia University, Depok, 16424, IndonesiaStudy Program of Civil Engineering-Specialization in Environmental Engineering, Departement of Civil Engineering, Faculty of Engineering, Indonesia University, Depok, 16424, IndonesiaStudy Program of Civil Engineering-Specialization in Environmental Engineering, Departement of Civil Engineering, Faculty of Engineering, Indonesia University, Depok, 16424, IndonesiaSuzuki Indomobil Motor Plant (SIMP) Cakung, East Jakarta, Indonesia generates wastewater containing heavy metals such as nickel, zinc, chromium, copper, and COD derived from the metal coating process using the electroplating system. Electroplating wastewater produced by this company contains Nickel and COD above the quality standards set by the Government of DKI Jakarta (Governor Regulation No. 69/2013). This research aims to analyze and compare the efficiency and kinetics of Nickel complexes and COD removal using the Advanced Oxidation Process (AOP) and Electrocoagulation (EC) method. Electroplating wastewater generated by SIMP Cakung (ratio of plating wastewater to overflow plating wastewater is 1:30) in this study had characteristics of 379–568 ppm (effluent standard = 75 ppm) of COD, and 87.555–121 ppm (effluent standard = 1 ppm) of Nickel. Preliminary experiments with the factorial design method indicated that independent variables (pH, current density, ozone flow rate, and contact time) had a critical influence/significance on the removal efficiency of Nickel complexes, while the influence of the above variables in COD removal efficiency was not significant. Optimum operating conditions for Nickel complexes and COD removal using both AOP and EC reactor were found in this study as well as the reaction kinetics of the removal rate. Our study found that the optimum operating conditions for Nickel complexes and COD removal using the AOP reactor were at the pH of 10, the ozone flow rate of 2 L/min, the contact time of 60 min (99.75% and 51.25% for Nickel and COD removal, respectively). For the EC reactor, the optimum condition for Nickel and COD removal are pH of 6.5, the current density of 20 mA/cm2 and the contact time of 50 min (99.75% and 51.25% for Nickel and COD removal, respectively). In these conditions, the AOP reactor in its optimum condition could remove Nickel and COD more compared to the EC reactor. This finding suggests that AOP technology is not only reliable in removing Nickel from electroplating industrial wastewater, but also it could reduce the loading of COD for further treatment units by more than 50%. Further studies in the effect of the longer contact time and higher ozone flowrate on COD removal is suggested.http://www.sciencedirect.com/science/article/pii/S240584402030164XEnvironmental chemical engineeringWaste treatmentWasteWastewater managementElectroplating wastewaterWastewater treatment
collection DOAJ
language English
format Article
sources DOAJ
author Setyo Sarwanto Moersidik
Rudi Nugroho
Mira Handayani
Kamilawati
Mochamad A. Pratama
spellingShingle Setyo Sarwanto Moersidik
Rudi Nugroho
Mira Handayani
Kamilawati
Mochamad A. Pratama
Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes
Heliyon
Environmental chemical engineering
Waste treatment
Waste
Wastewater management
Electroplating wastewater
Wastewater treatment
author_facet Setyo Sarwanto Moersidik
Rudi Nugroho
Mira Handayani
Kamilawati
Mochamad A. Pratama
author_sort Setyo Sarwanto Moersidik
title Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes
title_short Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes
title_full Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes
title_fullStr Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes
title_full_unstemmed Optimization and reaction kinetics on the removal of Nickel and COD from wastewater from electroplating industry using Electrocoagulation and Advanced Oxidation Processes
title_sort optimization and reaction kinetics on the removal of nickel and cod from wastewater from electroplating industry using electrocoagulation and advanced oxidation processes
publisher Elsevier
series Heliyon
issn 2405-8440
publishDate 2020-02-01
description Suzuki Indomobil Motor Plant (SIMP) Cakung, East Jakarta, Indonesia generates wastewater containing heavy metals such as nickel, zinc, chromium, copper, and COD derived from the metal coating process using the electroplating system. Electroplating wastewater produced by this company contains Nickel and COD above the quality standards set by the Government of DKI Jakarta (Governor Regulation No. 69/2013). This research aims to analyze and compare the efficiency and kinetics of Nickel complexes and COD removal using the Advanced Oxidation Process (AOP) and Electrocoagulation (EC) method. Electroplating wastewater generated by SIMP Cakung (ratio of plating wastewater to overflow plating wastewater is 1:30) in this study had characteristics of 379–568 ppm (effluent standard = 75 ppm) of COD, and 87.555–121 ppm (effluent standard = 1 ppm) of Nickel. Preliminary experiments with the factorial design method indicated that independent variables (pH, current density, ozone flow rate, and contact time) had a critical influence/significance on the removal efficiency of Nickel complexes, while the influence of the above variables in COD removal efficiency was not significant. Optimum operating conditions for Nickel complexes and COD removal using both AOP and EC reactor were found in this study as well as the reaction kinetics of the removal rate. Our study found that the optimum operating conditions for Nickel complexes and COD removal using the AOP reactor were at the pH of 10, the ozone flow rate of 2 L/min, the contact time of 60 min (99.75% and 51.25% for Nickel and COD removal, respectively). For the EC reactor, the optimum condition for Nickel and COD removal are pH of 6.5, the current density of 20 mA/cm2 and the contact time of 50 min (99.75% and 51.25% for Nickel and COD removal, respectively). In these conditions, the AOP reactor in its optimum condition could remove Nickel and COD more compared to the EC reactor. This finding suggests that AOP technology is not only reliable in removing Nickel from electroplating industrial wastewater, but also it could reduce the loading of COD for further treatment units by more than 50%. Further studies in the effect of the longer contact time and higher ozone flowrate on COD removal is suggested.
topic Environmental chemical engineering
Waste treatment
Waste
Wastewater management
Electroplating wastewater
Wastewater treatment
url http://www.sciencedirect.com/science/article/pii/S240584402030164X
work_keys_str_mv AT setyosarwantomoersidik optimizationandreactionkineticsontheremovalofnickelandcodfromwastewaterfromelectroplatingindustryusingelectrocoagulationandadvancedoxidationprocesses
AT rudinugroho optimizationandreactionkineticsontheremovalofnickelandcodfromwastewaterfromelectroplatingindustryusingelectrocoagulationandadvancedoxidationprocesses
AT mirahandayani optimizationandreactionkineticsontheremovalofnickelandcodfromwastewaterfromelectroplatingindustryusingelectrocoagulationandadvancedoxidationprocesses
AT kamilawati optimizationandreactionkineticsontheremovalofnickelandcodfromwastewaterfromelectroplatingindustryusingelectrocoagulationandadvancedoxidationprocesses
AT mochamadapratama optimizationandreactionkineticsontheremovalofnickelandcodfromwastewaterfromelectroplatingindustryusingelectrocoagulationandadvancedoxidationprocesses
_version_ 1724694124309774336