The quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2

Background: Clinical implementation of enhanced dynamic wedges (EDW) requires, as any other dynamic treatment, very serious quality assurance (QA) program. In this work, we presented the results of six-month evaluation of Varian enhanced dynamic wedges and detailed QA program for those wedges. Metho...

Full description

Bibliographic Details
Main Authors: Rutonjski Laza, Kuzmanović Zoran, Baucal Milutin, Petrović Borislava, Teodorović Milan
Format: Article
Language:English
Published: Institute of Oncology, Sremska Kamenica, Serbia 2008-01-01
Series:Archive of Oncology
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/0354-7310/2008/0354-73100802007R.pdf
id doaj-fc4b020428de4e09af5193f9607ed152
record_format Article
spelling doaj-fc4b020428de4e09af5193f9607ed1522020-11-24T22:57:24ZengInstitute of Oncology, Sremska Kamenica, SerbiaArchive of Oncology0354-73102008-01-01161-27910.2298/AOO0802007RThe quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2Rutonjski LazaKuzmanović ZoranBaucal MilutinPetrović BorislavaTeodorović MilanBackground: Clinical implementation of enhanced dynamic wedges (EDW) requires, as any other dynamic treatment, very serious quality assurance (QA) program. In this work, we presented the results of six-month evaluation of Varian enhanced dynamic wedges and detailed QA program for those wedges. Methods: The Sun Nuclear Daily QA Check 2 was used for QA purpose. The QA program included daily and monthly checks. The daily QA program included central axis dose and wedge angle measurements. Within the monthly QA program wedge factors and delivered STTs from the Dynalog files were checked. Results: Our daily QA measurements of dose and wedge angle showed the reproducibility error less than ±1.5%. On the other hand, monthly QA measurements of wedge factor the reproducibility error was less than ±0.5%. The monthly QA check of delivered STTs showed excellent agreement. Conclusion: During the six-month quality control we observed a good reproducibility in the delivery of EDW treatment. Also, the Sun Nuclear Daily QA Check 2 showed to be very satisfying in QA of the EDW treatment. http://www.doiserbia.nb.rs/img/doi/0354-7310/2008/0354-73100802007R.pdfquality assurancehealth careparticle acceleratorsradiotherapyconformalradiotherapy planningcomputer assistedradiometry
collection DOAJ
language English
format Article
sources DOAJ
author Rutonjski Laza
Kuzmanović Zoran
Baucal Milutin
Petrović Borislava
Teodorović Milan
spellingShingle Rutonjski Laza
Kuzmanović Zoran
Baucal Milutin
Petrović Borislava
Teodorović Milan
The quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2
Archive of Oncology
quality assurance
health care
particle accelerators
radiotherapy
conformal
radiotherapy planning
computer assisted
radiometry
author_facet Rutonjski Laza
Kuzmanović Zoran
Baucal Milutin
Petrović Borislava
Teodorović Milan
author_sort Rutonjski Laza
title The quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2
title_short The quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2
title_full The quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2
title_fullStr The quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2
title_full_unstemmed The quality assurance of Varian enhanced dynamic wedges using Daily QA Check 2
title_sort quality assurance of varian enhanced dynamic wedges using daily qa check 2
publisher Institute of Oncology, Sremska Kamenica, Serbia
series Archive of Oncology
issn 0354-7310
publishDate 2008-01-01
description Background: Clinical implementation of enhanced dynamic wedges (EDW) requires, as any other dynamic treatment, very serious quality assurance (QA) program. In this work, we presented the results of six-month evaluation of Varian enhanced dynamic wedges and detailed QA program for those wedges. Methods: The Sun Nuclear Daily QA Check 2 was used for QA purpose. The QA program included daily and monthly checks. The daily QA program included central axis dose and wedge angle measurements. Within the monthly QA program wedge factors and delivered STTs from the Dynalog files were checked. Results: Our daily QA measurements of dose and wedge angle showed the reproducibility error less than ±1.5%. On the other hand, monthly QA measurements of wedge factor the reproducibility error was less than ±0.5%. The monthly QA check of delivered STTs showed excellent agreement. Conclusion: During the six-month quality control we observed a good reproducibility in the delivery of EDW treatment. Also, the Sun Nuclear Daily QA Check 2 showed to be very satisfying in QA of the EDW treatment.
topic quality assurance
health care
particle accelerators
radiotherapy
conformal
radiotherapy planning
computer assisted
radiometry
url http://www.doiserbia.nb.rs/img/doi/0354-7310/2008/0354-73100802007R.pdf
work_keys_str_mv AT rutonjskilaza thequalityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT kuzmanoviczoran thequalityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT baucalmilutin thequalityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT petrovicborislava thequalityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT teodorovicmilan thequalityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT rutonjskilaza qualityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT kuzmanoviczoran qualityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT baucalmilutin qualityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT petrovicborislava qualityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
AT teodorovicmilan qualityassuranceofvarianenhanceddynamicwedgesusingdailyqacheck2
_version_ 1725650856052785152