Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas Pipeline
This paper discussed on the material selection and its robustness analysis towards the design of magnetic flux leakage capsule that most applied in oil and gas pipeline. Magnetic Flux Leakage is among the most famous and expensive technique in large scale oil and gas pipe diagnosis system. This tech...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IFSA Publishing, S.L.
2013-09-01
|
Series: | Sensors & Transducers |
Subjects: | |
Online Access: | http://www.sensorsportal.com/HTML/DIGEST/september_2013/P_1328.pdf |
id |
doaj-fd9875ef0f334175a3709261d3699ec5 |
---|---|
record_format |
Article |
spelling |
doaj-fd9875ef0f334175a3709261d3699ec52020-11-24T21:38:08ZengIFSA Publishing, S.L.Sensors & Transducers2306-85151726-54792013-09-0115696774Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas PipelineMaliki IBRAHIM0Zulkarnay ZAKARIA1Ali Aiman MUSTAPHA2Dennis Desmond SURIN3Mohd Nasir AYOB4Ibrahim BALKHIS5Ruzairi ABDUL RAHIM6School of Manufacturing Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, MalaysiaSchool of Mechatronic Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, MalaysiaSchool of Mechatronic Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, MalaysiaSchool of Manufacturing Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, MalaysiaSchool of Mechatronic Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, MalaysiaSchool of Mechatronic Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, MalaysiaProcess Tomography and Instrumentation Research Group (PROTOM-i), INFOCOMM Research Alliance, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor Bahru, MalaysiaThis paper discussed on the material selection and its robustness analysis towards the design of magnetic flux leakage capsule that most applied in oil and gas pipeline. Magnetic Flux Leakage is among the most famous and expensive technique in large scale oil and gas pipe diagnosis system. This technique applies strong magnetic fields to detect any strange in the inner surface of the pipes such as corrosion, crack or other symptoms which is bad to the pipe condition. The aim of this research is to study and develop a small scale, low cost and portable Magnetic Flux Leakage diagnosis system which suitable in detecting the defect in the inner side of steel pipe or steel tank structures. This system uses strong permanent magnet to generate strong magnetic field while Hall Effect sensor act as a receiver. It is found that the best suitable material for the Magnetic Flux Leakage Capsule is carbon steel. http://www.sensorsportal.com/HTML/DIGEST/september_2013/P_1328.pdfMagnetic Flux LeakageMaterial selectionRobustness analysis. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Maliki IBRAHIM Zulkarnay ZAKARIA Ali Aiman MUSTAPHA Dennis Desmond SURIN Mohd Nasir AYOB Ibrahim BALKHIS Ruzairi ABDUL RAHIM |
spellingShingle |
Maliki IBRAHIM Zulkarnay ZAKARIA Ali Aiman MUSTAPHA Dennis Desmond SURIN Mohd Nasir AYOB Ibrahim BALKHIS Ruzairi ABDUL RAHIM Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas Pipeline Sensors & Transducers Magnetic Flux Leakage Material selection Robustness analysis. |
author_facet |
Maliki IBRAHIM Zulkarnay ZAKARIA Ali Aiman MUSTAPHA Dennis Desmond SURIN Mohd Nasir AYOB Ibrahim BALKHIS Ruzairi ABDUL RAHIM |
author_sort |
Maliki IBRAHIM |
title |
Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas Pipeline |
title_short |
Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas Pipeline |
title_full |
Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas Pipeline |
title_fullStr |
Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas Pipeline |
title_full_unstemmed |
Magnetic Flux Leakage (MFL) Capsule Material Selection and Its Robustness Analysis in Oil and Gas Pipeline |
title_sort |
magnetic flux leakage (mfl) capsule material selection and its robustness analysis in oil and gas pipeline |
publisher |
IFSA Publishing, S.L. |
series |
Sensors & Transducers |
issn |
2306-8515 1726-5479 |
publishDate |
2013-09-01 |
description |
This paper discussed on the material selection and its robustness analysis towards the design of magnetic flux leakage capsule that most applied in oil and gas pipeline. Magnetic Flux Leakage is among the most famous and expensive technique in large scale oil and gas pipe diagnosis system. This technique applies strong magnetic fields to detect any strange in the inner surface of the pipes such as corrosion, crack or other symptoms which is bad to the pipe condition. The aim of this research is to study and develop a small scale, low cost and portable Magnetic Flux Leakage diagnosis system which suitable in detecting the defect in the inner side of steel pipe or steel tank structures. This system uses strong permanent magnet to generate strong magnetic field while Hall Effect sensor act as a receiver. It is found that the best suitable material for the Magnetic Flux Leakage Capsule is carbon steel.
|
topic |
Magnetic Flux Leakage Material selection Robustness analysis. |
url |
http://www.sensorsportal.com/HTML/DIGEST/september_2013/P_1328.pdf |
work_keys_str_mv |
AT malikiibrahim magneticfluxleakagemflcapsulematerialselectionanditsrobustnessanalysisinoilandgaspipeline AT zulkarnayzakaria magneticfluxleakagemflcapsulematerialselectionanditsrobustnessanalysisinoilandgaspipeline AT aliaimanmustapha magneticfluxleakagemflcapsulematerialselectionanditsrobustnessanalysisinoilandgaspipeline AT dennisdesmondsurin magneticfluxleakagemflcapsulematerialselectionanditsrobustnessanalysisinoilandgaspipeline AT mohdnasirayob magneticfluxleakagemflcapsulematerialselectionanditsrobustnessanalysisinoilandgaspipeline AT ibrahimbalkhis magneticfluxleakagemflcapsulematerialselectionanditsrobustnessanalysisinoilandgaspipeline AT ruzairiabdulrahim magneticfluxleakagemflcapsulematerialselectionanditsrobustnessanalysisinoilandgaspipeline |
_version_ |
1725935324655255552 |