Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
OBJETIVO: Determinar o comportamento dinâmico do fluxo sanguíneo da microcirculação digital, antes e após dois estímulos frios (EF) de diferentes intensidades, utilizando o método do Laser Doppler Imaging (LDI) em pacientes com esclerose sistêmica (ES) e controles saudáveis. MÉTODOS: Foram incluídos...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Reumatologia
2010-04-01
|
Series: | Revista Brasileira de Reumatologia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042010000200003 |
id |
doaj-ff29745837e9462ab0a357272815c22c |
---|---|
record_format |
Article |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Marcelo José Uchoa Corrêa Sandro F Perazzio Luís Eduardo Coelho Andrade Cristiane Kayser |
spellingShingle |
Marcelo José Uchoa Corrêa Sandro F Perazzio Luís Eduardo Coelho Andrade Cristiane Kayser Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis Revista Brasileira de Reumatologia esclerose sistêmica fenômeno de Raynaud microcirculação Laser Doppler imaging systemic sclerosis Raynaud's phenomenon microcirculation Laser Doppler Imaging |
author_facet |
Marcelo José Uchoa Corrêa Sandro F Perazzio Luís Eduardo Coelho Andrade Cristiane Kayser |
author_sort |
Marcelo José Uchoa Corrêa |
title |
Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis |
title_short |
Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis |
title_full |
Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis |
title_fullStr |
Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis |
title_full_unstemmed |
Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis |
title_sort |
laser doppler imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis |
publisher |
Sociedade Brasileira de Reumatologia |
series |
Revista Brasileira de Reumatologia |
issn |
0482-5004 1809-4570 |
publishDate |
2010-04-01 |
description |
OBJETIVO: Determinar o comportamento dinâmico do fluxo sanguíneo da microcirculação digital, antes e após dois estímulos frios (EF) de diferentes intensidades, utilizando o método do Laser Doppler Imaging (LDI) em pacientes com esclerose sistêmica (ES) e controles saudáveis. MÉTODOS: Foram incluídos 14 pacientes com ES (51,2 ± 5,5 anos de idade) e 12 controles saudáveis (44,8 ± 9,9 anos). Foram realizados dois protocolos alternativos de EF (submersão das mãos em água a 10 ºC ou 15 ºC, durante 1 minuto). O fluxo médio das quatro polpas digitais da mão esquerda (FPD) foi mensurado com a utilização do LDI (Moor LDI-VR), em condições basais, nos períodos de 1, 4, 10, 25 e 40 minutos após EF. RESULTADOS: O fluxo basal foi significativamente menor em ambos os protocolos em pacientes com ES comparados a controles (312,9 ± 102,7 versus 465,4 ± 135,4 PU, P = 0,006, no protocolo a 15 ºC; 305,2 ± 121,0 versus 437,9 ± 119,8 PU, P = 0,01, no protocolo a 10 ºC). Nos controles houve declínio significativo do FPD após EF, em comparação aos valores basais apenas no tempo de um minuto após EF a 15 ºC (P = 0,001) e nos tempos de 1 e 25 minutos após EF a 10 ºC (P = 0,005; P = 0,001, respectivamente). Nos pacientes com ES, houve declínio significativo do FPD nos tempos de 1, 4 e 10 minutos após ambos EFs (P < 0,000; P = 0,002; P = 0,014, EF a 15 ºC; P < 0,000; P = 0,004; P = 0,001, EF a 10 ºC, respectivamente). CONCLUSÃO: LDI demonstrou baixa perfusão em polpa digital em condições basais e elevado declínio de perfusão com retardo na recuperação após EF na ES. A quantificação do fluxo sanguíneo pelo LDI pode ser útil para o seguimento longitudinal da doença e para a monitoração de intervenções terapêuticas na ES.<br>OBJECTIVES: The objective of this study was to investigate the dynamic behavior of the blood flow of the microvascular circulation of the fingertips before and after two cold stimuli (CS), using Laser Doppler Imaging with different intensities in patients with systemic sclerosis (SSc) and in healthy individuals. PATIENTS AND METHODS: Fourteen SSc patients (51.2 ± 5.5 years) with Raynaud's phenomenon and 12 healthy controls (44.8 ± 9.0 years) were included in this study. Two CS protocols (submersion of the hands in water at 10 ºC or 15 ºC for 1 minute) were performed on the same day. Mean fingertip blood flow (FBF) of four digits of the left hand was measured using LDI (Moor LDI-VR, Moor Instruments) at baseline and at 1, 4, 10, 25, and 40 minutes after CS. RESULTS: Baseline blood flow was significantly lower in both CS protocols in SSc patients when compared to controls (312.9 ± 102.7 vs 465.4 ± 135.4 PU, P = 0.006 at 15 ºC; 305.2 ± 121.0 vs 437.9 ± 119.8 PU; P = 0.01 at 10 ºC). In the control group, a significant decrease in FBF after CS, when compared to baseline, was observed 1 minute (P = 0.001) after CS at 15 ºC and at 1 (P = 0.005) and 25 minutes (P = 0.001) after CS at 10 ºC. In SSc patients, a significant decrease in FBF was observed in both CS protocols at 1, 4, and 10 minutes (P < 0.000; P = 0.002; P = 0.014, after CS at 15 ºC; P < 0.000; P = 0.004; P = 0.001, after CS at 10 ºC). CONCLUSIONS: Laser Doppler Imaging showed lower baseline fingertip perfusion and further reduction after CS in SSc patients compared to controls. Quantification of fingertip blood flow by LDI may be useful in the longitudinal monitoring of the disease status and therapeutic interventions in SSc. |
topic |
esclerose sistêmica fenômeno de Raynaud microcirculação Laser Doppler imaging systemic sclerosis Raynaud's phenomenon microcirculation Laser Doppler Imaging |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042010000200003 |
work_keys_str_mv |
AT marcelojoseuchoacorrea laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis AT sandrofperazzio laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis AT luiseduardocoelhoandrade laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis AT cristianekayser laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis |
_version_ |
1725078319523692544 |
spelling |
doaj-ff29745837e9462ab0a357272815c22c2020-11-25T01:33:16ZengSociedade Brasileira de Reumatologia Revista Brasileira de Reumatologia0482-50041809-45702010-04-0150212813410.1590/S0482-50042010000200003Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosisMarcelo José Uchoa CorrêaSandro F PerazzioLuís Eduardo Coelho AndradeCristiane KayserOBJETIVO: Determinar o comportamento dinâmico do fluxo sanguíneo da microcirculação digital, antes e após dois estímulos frios (EF) de diferentes intensidades, utilizando o método do Laser Doppler Imaging (LDI) em pacientes com esclerose sistêmica (ES) e controles saudáveis. MÉTODOS: Foram incluídos 14 pacientes com ES (51,2 ± 5,5 anos de idade) e 12 controles saudáveis (44,8 ± 9,9 anos). Foram realizados dois protocolos alternativos de EF (submersão das mãos em água a 10 ºC ou 15 ºC, durante 1 minuto). O fluxo médio das quatro polpas digitais da mão esquerda (FPD) foi mensurado com a utilização do LDI (Moor LDI-VR), em condições basais, nos períodos de 1, 4, 10, 25 e 40 minutos após EF. RESULTADOS: O fluxo basal foi significativamente menor em ambos os protocolos em pacientes com ES comparados a controles (312,9 ± 102,7 versus 465,4 ± 135,4 PU, P = 0,006, no protocolo a 15 ºC; 305,2 ± 121,0 versus 437,9 ± 119,8 PU, P = 0,01, no protocolo a 10 ºC). Nos controles houve declínio significativo do FPD após EF, em comparação aos valores basais apenas no tempo de um minuto após EF a 15 ºC (P = 0,001) e nos tempos de 1 e 25 minutos após EF a 10 ºC (P = 0,005; P = 0,001, respectivamente). Nos pacientes com ES, houve declínio significativo do FPD nos tempos de 1, 4 e 10 minutos após ambos EFs (P < 0,000; P = 0,002; P = 0,014, EF a 15 ºC; P < 0,000; P = 0,004; P = 0,001, EF a 10 ºC, respectivamente). CONCLUSÃO: LDI demonstrou baixa perfusão em polpa digital em condições basais e elevado declínio de perfusão com retardo na recuperação após EF na ES. A quantificação do fluxo sanguíneo pelo LDI pode ser útil para o seguimento longitudinal da doença e para a monitoração de intervenções terapêuticas na ES.<br>OBJECTIVES: The objective of this study was to investigate the dynamic behavior of the blood flow of the microvascular circulation of the fingertips before and after two cold stimuli (CS), using Laser Doppler Imaging with different intensities in patients with systemic sclerosis (SSc) and in healthy individuals. PATIENTS AND METHODS: Fourteen SSc patients (51.2 ± 5.5 years) with Raynaud's phenomenon and 12 healthy controls (44.8 ± 9.0 years) were included in this study. Two CS protocols (submersion of the hands in water at 10 ºC or 15 ºC for 1 minute) were performed on the same day. Mean fingertip blood flow (FBF) of four digits of the left hand was measured using LDI (Moor LDI-VR, Moor Instruments) at baseline and at 1, 4, 10, 25, and 40 minutes after CS. RESULTS: Baseline blood flow was significantly lower in both CS protocols in SSc patients when compared to controls (312.9 ± 102.7 vs 465.4 ± 135.4 PU, P = 0.006 at 15 ºC; 305.2 ± 121.0 vs 437.9 ± 119.8 PU; P = 0.01 at 10 ºC). In the control group, a significant decrease in FBF after CS, when compared to baseline, was observed 1 minute (P = 0.001) after CS at 15 ºC and at 1 (P = 0.005) and 25 minutes (P = 0.001) after CS at 10 ºC. In SSc patients, a significant decrease in FBF was observed in both CS protocols at 1, 4, and 10 minutes (P < 0.000; P = 0.002; P = 0.014, after CS at 15 ºC; P < 0.000; P = 0.004; P = 0.001, after CS at 10 ºC). CONCLUSIONS: Laser Doppler Imaging showed lower baseline fingertip perfusion and further reduction after CS in SSc patients compared to controls. Quantification of fingertip blood flow by LDI may be useful in the longitudinal monitoring of the disease status and therapeutic interventions in SSc.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042010000200003esclerose sistêmicafenômeno de RaynaudmicrocirculaçãoLaser Doppler imagingsystemic sclerosisRaynaud's phenomenonmicrocirculationLaser Doppler Imaging |