Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis

OBJETIVO: Determinar o comportamento dinâmico do fluxo sanguíneo da microcirculação digital, antes e após dois estímulos frios (EF) de diferentes intensidades, utilizando o método do Laser Doppler Imaging (LDI) em pacientes com esclerose sistêmica (ES) e controles saudáveis. MÉTODOS: Foram incluídos...

Full description

Bibliographic Details
Main Authors: Marcelo José Uchoa Corrêa, Sandro F Perazzio, Luís Eduardo Coelho Andrade, Cristiane Kayser
Format: Article
Language:English
Published: Sociedade Brasileira de Reumatologia 2010-04-01
Series:Revista Brasileira de Reumatologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042010000200003
id doaj-ff29745837e9462ab0a357272815c22c
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Marcelo José Uchoa Corrêa
Sandro F Perazzio
Luís Eduardo Coelho Andrade
Cristiane Kayser
spellingShingle Marcelo José Uchoa Corrêa
Sandro F Perazzio
Luís Eduardo Coelho Andrade
Cristiane Kayser
Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
Revista Brasileira de Reumatologia
esclerose sistêmica
fenômeno de Raynaud
microcirculação
Laser Doppler imaging
systemic sclerosis
Raynaud's phenomenon
microcirculation
Laser Doppler Imaging
author_facet Marcelo José Uchoa Corrêa
Sandro F Perazzio
Luís Eduardo Coelho Andrade
Cristiane Kayser
author_sort Marcelo José Uchoa Corrêa
title Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
title_short Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
title_full Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
title_fullStr Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
title_full_unstemmed Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
title_sort laser doppler imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis
publisher Sociedade Brasileira de Reumatologia
series Revista Brasileira de Reumatologia
issn 0482-5004
1809-4570
publishDate 2010-04-01
description OBJETIVO: Determinar o comportamento dinâmico do fluxo sanguíneo da microcirculação digital, antes e após dois estímulos frios (EF) de diferentes intensidades, utilizando o método do Laser Doppler Imaging (LDI) em pacientes com esclerose sistêmica (ES) e controles saudáveis. MÉTODOS: Foram incluídos 14 pacientes com ES (51,2 ± 5,5 anos de idade) e 12 controles saudáveis (44,8 ± 9,9 anos). Foram realizados dois protocolos alternativos de EF (submersão das mãos em água a 10 ºC ou 15 ºC, durante 1 minuto). O fluxo médio das quatro polpas digitais da mão esquerda (FPD) foi mensurado com a utilização do LDI (Moor LDI-VR), em condições basais, nos períodos de 1, 4, 10, 25 e 40 minutos após EF. RESULTADOS: O fluxo basal foi significativamente menor em ambos os protocolos em pacientes com ES comparados a controles (312,9 ± 102,7 versus 465,4 ± 135,4 PU, P = 0,006, no protocolo a 15 ºC; 305,2 ± 121,0 versus 437,9 ± 119,8 PU, P = 0,01, no protocolo a 10 ºC). Nos controles houve declínio significativo do FPD após EF, em comparação aos valores basais apenas no tempo de um minuto após EF a 15 ºC (P = 0,001) e nos tempos de 1 e 25 minutos após EF a 10 ºC (P = 0,005; P = 0,001, respectivamente). Nos pacientes com ES, houve declínio significativo do FPD nos tempos de 1, 4 e 10 minutos após ambos EFs (P < 0,000; P = 0,002; P = 0,014, EF a 15 ºC; P < 0,000; P = 0,004; P = 0,001, EF a 10 ºC, respectivamente). CONCLUSÃO: LDI demonstrou baixa perfusão em polpa digital em condições basais e elevado declínio de perfusão com retardo na recuperação após EF na ES. A quantificação do fluxo sanguíneo pelo LDI pode ser útil para o seguimento longitudinal da doença e para a monitoração de intervenções terapêuticas na ES.<br>OBJECTIVES: The objective of this study was to investigate the dynamic behavior of the blood flow of the microvascular circulation of the fingertips before and after two cold stimuli (CS), using Laser Doppler Imaging with different intensities in patients with systemic sclerosis (SSc) and in healthy individuals. PATIENTS AND METHODS: Fourteen SSc patients (51.2 ± 5.5 years) with Raynaud's phenomenon and 12 healthy controls (44.8 ± 9.0 years) were included in this study. Two CS protocols (submersion of the hands in water at 10 ºC or 15 ºC for 1 minute) were performed on the same day. Mean fingertip blood flow (FBF) of four digits of the left hand was measured using LDI (Moor LDI-VR, Moor Instruments) at baseline and at 1, 4, 10, 25, and 40 minutes after CS. RESULTS: Baseline blood flow was significantly lower in both CS protocols in SSc patients when compared to controls (312.9 ± 102.7 vs 465.4 ± 135.4 PU, P = 0.006 at 15 ºC; 305.2 ± 121.0 vs 437.9 ± 119.8 PU; P = 0.01 at 10 ºC). In the control group, a significant decrease in FBF after CS, when compared to baseline, was observed 1 minute (P = 0.001) after CS at 15 ºC and at 1 (P = 0.005) and 25 minutes (P = 0.001) after CS at 10 ºC. In SSc patients, a significant decrease in FBF was observed in both CS protocols at 1, 4, and 10 minutes (P < 0.000; P = 0.002; P = 0.014, after CS at 15 ºC; P < 0.000; P = 0.004; P = 0.001, after CS at 10 ºC). CONCLUSIONS: Laser Doppler Imaging showed lower baseline fingertip perfusion and further reduction after CS in SSc patients compared to controls. Quantification of fingertip blood flow by LDI may be useful in the longitudinal monitoring of the disease status and therapeutic interventions in SSc.
topic esclerose sistêmica
fenômeno de Raynaud
microcirculação
Laser Doppler imaging
systemic sclerosis
Raynaud's phenomenon
microcirculation
Laser Doppler Imaging
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042010000200003
work_keys_str_mv AT marcelojoseuchoacorrea laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis
AT sandrofperazzio laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis
AT luiseduardocoelhoandrade laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis
AT cristianekayser laserdopplerimagingparaquantificacaodofluxosanguineodepolpadigitalemcondicoesbasaiseaposestimulofrioempacientescomesclerosesistemicaquantificationofbasaldigitalbloodflowandaftercoldstimulusbylaserdopplerimaginginpatientswithsystemicsclerosis
_version_ 1725078319523692544
spelling doaj-ff29745837e9462ab0a357272815c22c2020-11-25T01:33:16ZengSociedade Brasileira de Reumatologia Revista Brasileira de Reumatologia0482-50041809-45702010-04-0150212813410.1590/S0482-50042010000200003Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosisMarcelo José Uchoa CorrêaSandro F PerazzioLuís Eduardo Coelho AndradeCristiane KayserOBJETIVO: Determinar o comportamento dinâmico do fluxo sanguíneo da microcirculação digital, antes e após dois estímulos frios (EF) de diferentes intensidades, utilizando o método do Laser Doppler Imaging (LDI) em pacientes com esclerose sistêmica (ES) e controles saudáveis. MÉTODOS: Foram incluídos 14 pacientes com ES (51,2 ± 5,5 anos de idade) e 12 controles saudáveis (44,8 ± 9,9 anos). Foram realizados dois protocolos alternativos de EF (submersão das mãos em água a 10 ºC ou 15 ºC, durante 1 minuto). O fluxo médio das quatro polpas digitais da mão esquerda (FPD) foi mensurado com a utilização do LDI (Moor LDI-VR), em condições basais, nos períodos de 1, 4, 10, 25 e 40 minutos após EF. RESULTADOS: O fluxo basal foi significativamente menor em ambos os protocolos em pacientes com ES comparados a controles (312,9 ± 102,7 versus 465,4 ± 135,4 PU, P = 0,006, no protocolo a 15 ºC; 305,2 ± 121,0 versus 437,9 ± 119,8 PU, P = 0,01, no protocolo a 10 ºC). Nos controles houve declínio significativo do FPD após EF, em comparação aos valores basais apenas no tempo de um minuto após EF a 15 ºC (P = 0,001) e nos tempos de 1 e 25 minutos após EF a 10 ºC (P = 0,005; P = 0,001, respectivamente). Nos pacientes com ES, houve declínio significativo do FPD nos tempos de 1, 4 e 10 minutos após ambos EFs (P < 0,000; P = 0,002; P = 0,014, EF a 15 ºC; P < 0,000; P = 0,004; P = 0,001, EF a 10 ºC, respectivamente). CONCLUSÃO: LDI demonstrou baixa perfusão em polpa digital em condições basais e elevado declínio de perfusão com retardo na recuperação após EF na ES. A quantificação do fluxo sanguíneo pelo LDI pode ser útil para o seguimento longitudinal da doença e para a monitoração de intervenções terapêuticas na ES.<br>OBJECTIVES: The objective of this study was to investigate the dynamic behavior of the blood flow of the microvascular circulation of the fingertips before and after two cold stimuli (CS), using Laser Doppler Imaging with different intensities in patients with systemic sclerosis (SSc) and in healthy individuals. PATIENTS AND METHODS: Fourteen SSc patients (51.2 ± 5.5 years) with Raynaud's phenomenon and 12 healthy controls (44.8 ± 9.0 years) were included in this study. Two CS protocols (submersion of the hands in water at 10 ºC or 15 ºC for 1 minute) were performed on the same day. Mean fingertip blood flow (FBF) of four digits of the left hand was measured using LDI (Moor LDI-VR, Moor Instruments) at baseline and at 1, 4, 10, 25, and 40 minutes after CS. RESULTS: Baseline blood flow was significantly lower in both CS protocols in SSc patients when compared to controls (312.9 ± 102.7 vs 465.4 ± 135.4 PU, P = 0.006 at 15 ºC; 305.2 ± 121.0 vs 437.9 ± 119.8 PU; P = 0.01 at 10 ºC). In the control group, a significant decrease in FBF after CS, when compared to baseline, was observed 1 minute (P = 0.001) after CS at 15 ºC and at 1 (P = 0.005) and 25 minutes (P = 0.001) after CS at 10 ºC. In SSc patients, a significant decrease in FBF was observed in both CS protocols at 1, 4, and 10 minutes (P < 0.000; P = 0.002; P = 0.014, after CS at 15 ºC; P < 0.000; P = 0.004; P = 0.001, after CS at 10 ºC). CONCLUSIONS: Laser Doppler Imaging showed lower baseline fingertip perfusion and further reduction after CS in SSc patients compared to controls. Quantification of fingertip blood flow by LDI may be useful in the longitudinal monitoring of the disease status and therapeutic interventions in SSc.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042010000200003esclerose sistêmicafenômeno de RaynaudmicrocirculaçãoLaser Doppler imagingsystemic sclerosisRaynaud's phenomenonmicrocirculationLaser Doppler Imaging