Bending strength of steel fibre reinforced concrete ribbed slab panel / Amir Syafiq Samsudin ... [et al.].

Nowadays, demands in the application of fibre in concrete increase gradually as an engineering material. Rapid cost increment of material causes the increase in demand of new technology that provides safe, efficient and economical design for the present and future application. The introduction ofrib...

Full description

Bibliographic Details
Main Authors: Samsudin, Amir Syafiq (Author), Mohd Hashim, Mohd Hisbany (Author), Hamzah, Siti Hawa (Author), Abu Bakar, Afidah (Author)
Format: Article
Language:English
Published: Institute of Research Management and Innovation and UiTM Press, 2018.
Subjects:
Online Access:Get fulltext
View Fulltext in UiTM IR
LEADER 02181 am a22002053u 4500
001 21288
042 |a dc 
100 1 0 |a Samsudin, Amir Syafiq  |e author 
700 1 0 |a Mohd Hashim, Mohd Hisbany  |e author 
700 1 0 |a Hamzah, Siti Hawa  |e author 
700 1 0 |a Abu Bakar, Afidah  |e author 
245 0 0 |a Bending strength of steel fibre reinforced concrete ribbed slab panel / Amir Syafiq Samsudin ... [et al.]. 
260 |b Institute of Research Management and Innovation and UiTM Press,   |c 2018. 
856 |z Get fulltext  |u https://ir.uitm.edu.my/id/eprint/21288/1/AJ_AMIR%20SYAFIQ%20SAMSUDIN%20SRJ%2018.pdf 
856 |z View Fulltext in UiTM IR  |u https://ir.uitm.edu.my/id/eprint/21288/ 
520 |a Nowadays, demands in the application of fibre in concrete increase gradually as an engineering material. Rapid cost increment of material causes the increase in demand of new technology that provides safe, efficient and economical design for the present and future application. The introduction ofribbed slab reduces concrete materials and thusthe cost, but the strength of the structure also reduces due to the reducing of material. Steel fibre reinforced concrete (SFRC) has the ability to maintain a part of its tensile strength prior to crack in order to resist more loading compared to conventional concrete. Meanwhile, the ribbed slab can help in material reduction. This research investigated on the bending strength of 2-ribbed and 3-ribbed concrete slab with steel fibre reinforcement under static loading with a span of 1500 mm and 1000 mm x 75 mm in cross section. An amount of 40 kg/m steel fibre of all total concrete volume was used as reinforcement instead of conventional bars with concrete grade 30 N/mm2 . The slab wastested underthree-point bending. Load versus deflection curve was plotted to illustrate the result and to compare the deflection between control and ribbed slab. Thisresearch showsthat SFRCRibbed Slab capable to withstand the same amount of load as normal slab structure, although the concrete volume reduces up to 20%. 
546 |a en 
650 0 4 |a Dynamic loading conditions. Structural dynamics. Vibrations 
650 0 4 |a Earthwork. Foundations 
655 7 |a Article