Performance based approach of Cellular Steel Beam (CSB) exposed to fire / Fariz Aswan Ahmad Zakwan...[et al.]

This paper presents a numerical analysis of simply supported cellular steel beam (CSB) at elevated temperatures. Currently, CSB is increasingly used as the main structural element in multi-storey buildings, warehouses and any steel structures. Typical steel beams are mainly used as a dwelling load b...

Full description

Bibliographic Details
Main Authors: Ahmad Zakwan, Fariz Aswan (Author), Renga, Rao Krishnamoorthy (Author), Ibrahim, Azmi (Author), Mohd. Ismail, Abdul Manaff (Author)
Format: Article
Language:English
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM), 2019.
Subjects:
Online Access:Get fulltext
View Fulltext in UiTM IR
LEADER 01722 am a22001933u 4500
001 36357
042 |a dc 
100 1 0 |a Ahmad Zakwan, Fariz Aswan  |e author 
700 1 0 |a Renga, Rao Krishnamoorthy  |e author 
700 1 0 |a Ibrahim, Azmi  |e author 
700 1 0 |a Mohd. Ismail, Abdul Manaff  |e author 
245 0 0 |a Performance based approach of Cellular Steel Beam (CSB) exposed to fire / Fariz Aswan Ahmad Zakwan...[et al.] 
260 |b Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM),   |c 2019. 
856 |z Get fulltext  |u https://ir.uitm.edu.my/id/eprint/36357/1/36357.pdf 
856 |z View Fulltext in UiTM IR  |u https://ir.uitm.edu.my/id/eprint/36357/ 
520 |a This paper presents a numerical analysis of simply supported cellular steel beam (CSB) at elevated temperatures. Currently, CSB is increasingly used as the main structural element in multi-storey buildings, warehouses and any steel structures. Typical steel beams are mainly used as a dwelling load bearing capacity. CSB is one of the options to replace the former steel beam. Several advantages can be gained when adopting CSB as the main structural element in structures. However, several drawbacks have restricted the structural performance of CSB under applied load, especially under fire exposure. Fire is one of the major catastrophe that may endanger any structural steel member in a steel frame building under certain duration. It is important to reduce the member temperature induce by fire exposure to prolong the time before the CSB failed. Experimental data available in the literature review will be used to validate with numerical simulation in this research. 
546 |a en 
650 0 4 |a TJ Mechanical engineering and machinery 
655 7 |a Article