Near-common-path interferometer for imaging Fourier-transform spectroscopy in wide-field microscopy

Imaging Fourier-transform spectroscopy (IFTS) is a powerful method for biological hyperspectral analysis based on various imaging modalities, such as fluorescence or Raman. Since the measurements are taken in the Fourier space of the spectrum, it can also take advantage of compressed sensing strateg...

Full description

Bibliographic Details
Main Authors: Heemskerk, Hans (Author), Wadduwage, Dushan Nawoda (Contributor), Singh, Vijay Raj (Contributor), Choi, Heejin (Contributor), Yaqoob, Zahid (Contributor), So, Peter T. C. (Contributor), Matsudaira, Paul T. (Author)
Other Authors: Institute for Medical Engineering and Science (Contributor), Massachusetts Institute of Technology. Department of Biological Engineering (Contributor), Massachusetts Institute of Technology. Department of Biology (Contributor), Massachusetts Institute of Technology. Department of Chemistry (Contributor), Massachusetts Institute of Technology. Department of Mechanical Engineering (Contributor), Massachusetts Institute of Technology. Spectroscopy Laboratory (Contributor), Matsudaira, Paul T (Contributor)
Format: Article
Language:English
Published: The Optical Society, 2019-02-11T18:30:36Z.
Subjects:
Online Access:Get fulltext
Description
Summary:Imaging Fourier-transform spectroscopy (IFTS) is a powerful method for biological hyperspectral analysis based on various imaging modalities, such as fluorescence or Raman. Since the measurements are taken in the Fourier space of the spectrum, it can also take advantage of compressed sensing strategies. IFTS has been readily implemented in high-throughput, high-content microscope systems based on wide-field imaging modalities. However, there are limitations in existing wide-field IFTS designs. Non-common-path approaches are less phase-stable. Alternatively, designs based on the common-path Sagnac interferometer are stable, but incompatible with high-throughput imaging. They require exhaustive sequential scanning over large interferometric path delays, making compressive strategic data acquisition impossible. In this paper, we present a novel phase-stable, near-common-path interferometer enabling high-throughput hyperspectral imaging based on strategic data acquisition. Our results suggest that this approach can improve throughput over those of many other wide-field spectral techniques by more than an order of magnitude without compromising phase stability.
National Institutes of Health (U.S.) (1R01HL121386-01A1)
National Institutes of Health (U.S.) (1U01CA202177-01)
National Institutes of Health (U.S.) (4R44EB012415)
National Institutes of Health (U.S.) (5R01NS051320)
National Institutes of Health (U.S.) (9P41EB015871-26A1)
Singapore-MIT Alliance. BioSystems and Micromechanics (BioSyM) Inter-Disciplinary Research Group
Hamamatsu Corporation
Samsung Advanced Institute of Technology