Sparsity-Promoting Calibration for GRAPPA Accelerated Parallel MRI Reconstruction

The amount of calibration data needed to produce images of adequate quality can prevent auto-calibrating parallel imaging reconstruction methods like generalized autocalibrating partially parallel acquisitions (GRAPPA) from achieving a high total acceleration factor. To improve the quality of calibr...

Full description

Bibliographic Details
Main Authors: Weller, Daniel S. (Author), Polimeni, Jonathan R. (Author), Grady, Leo (Author), Wald, Lawrence L. (Author), Adalsteinsson, Elfar (Contributor), Goyal, Vivek K. (Contributor)
Other Authors: Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science (Contributor), Massachusetts Institute of Technology. Research Laboratory of Electronics (Contributor)
Format: Article
Language:English
Published: Institute of Electrical and Electronics Engineers (IEEE), 2014-03-21T16:02:04Z.
Subjects:
Online Access:Get fulltext
LEADER 02812 am a22003373u 4500
001 85875
042 |a dc 
100 1 0 |a Weller, Daniel S.  |e author 
100 1 0 |a Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science  |e contributor 
100 1 0 |a Massachusetts Institute of Technology. Research Laboratory of Electronics  |e contributor 
100 1 0 |a Adalsteinsson, Elfar  |e contributor 
100 1 0 |a Goyal, Vivek K.  |e contributor 
700 1 0 |a Polimeni, Jonathan R.  |e author 
700 1 0 |a Grady, Leo  |e author 
700 1 0 |a Wald, Lawrence L.  |e author 
700 1 0 |a Adalsteinsson, Elfar  |e author 
700 1 0 |a Goyal, Vivek K.  |e author 
245 0 0 |a Sparsity-Promoting Calibration for GRAPPA Accelerated Parallel MRI Reconstruction 
260 |b Institute of Electrical and Electronics Engineers (IEEE),   |c 2014-03-21T16:02:04Z. 
856 |z Get fulltext  |u http://hdl.handle.net/1721.1/85875 
520 |a The amount of calibration data needed to produce images of adequate quality can prevent auto-calibrating parallel imaging reconstruction methods like generalized autocalibrating partially parallel acquisitions (GRAPPA) from achieving a high total acceleration factor. To improve the quality of calibration when the number of auto-calibration signal (ACS) lines is restricted, we propose a sparsity-promoting regularized calibration method that finds a GRAPPA kernel consistent with the ACS fit equations that yields jointly sparse reconstructed coil channel images. Several experiments evaluate the performance of the proposed method relative to unregularized and existing regularized calibration methods for both low-quality and underdetermined fits from the ACS lines. These experiments demonstrate that the proposed method, like other regularization methods, is capable of mitigating noise amplification, and in addition, the proposed method is particularly effective at minimizing coherent aliasing artifacts caused by poor kernel calibration in real data. Using the proposed method, we can increase the total achievable acceleration while reducing degradation of the reconstructed image better than existing regularized calibration methods. 
520 |a National Science Foundation (U.S.) (CAREER Grant 0643836) 
520 |a National Institutes of Health (U.S.) (Grant NIH R01 EB007942) 
520 |a National Institutes of Health (U.S.) (Grant NIH R01 EB006847) 
520 |a National Institutes of Health (U.S.) (Grant NIH P41 RR014075) 
520 |a National Institutes of Health (U.S.) (Grant NIH K01 EB011498) 
520 |a National Institutes of Health (U.S.) (Grant NIH F32 EB015914) 
520 |a National Science Foundation (U.S.). Graduate Research Fellowship Program 
546 |a en_US 
655 7 |a Article 
773 |t IEEE Transactions on Medical Imaging