Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams

Yes === This paper presents the experimental results of five large-scale hybrid glass fiber reinforced polymer (GFRP)-steel reinforced concrete continuous beams compared with two concrete continuous beams reinforced with either steel or GFRP bars as reference beams. In addition, two simply supported...

Full description

Bibliographic Details
Main Authors: Araba, Almahdi M.A.A., Ashour, Ashraf F.
Language:en
Published: 2019
Subjects:
Online Access:http://hdl.handle.net/10454/16853
id ndltd-BRADFORD-oai-bradscholars.brad.ac.uk-10454-16853
record_format oai_dc
spelling ndltd-BRADFORD-oai-bradscholars.brad.ac.uk-10454-168532021-10-13T05:01:14Z Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams Araba, Almahdi M.A.A. Ashour, Ashraf F. Glass fiber reinforced polymer (GFRP)-steel Reinforced concrete continuous beams Flexural performance Yes This paper presents the experimental results of five large-scale hybrid glass fiber reinforced polymer (GFRP)-steel reinforced concrete continuous beams compared with two concrete continuous beams reinforced with either steel or GFRP bars as reference beams. In addition, two simply supported concrete beams reinforced with hybrid GFRP/steel were tested. The amount of longitudinal GFRP, steel reinforcements and area of steel bars to GFRP bars were the main investigated parameter in this study. The experimental results showed that increasing the GFRP reinforcement ratio simultaneously at the sagging and hogging zones resulted in an increase in the load capacity, however, less ductile behaviour. On the other hand, increasing the steel reinforcement ratio at critical sections resulted in more ductile behaviour, however, less load capacity increase after yielding of steel. The test results were compared with code equations and available theoretical models for predicting the beam load capacity and load-deflection response. It was concluded that Yoon's model reasonably predicted the deflection of the hybrid beams tested, whereas, the ACI.440.1R-15 equation underestimated the hybrid beam deflections. It was also shown that the load capacity prediction for hybrid reinforced concrete continuous beams based on a collapse mechanism with plastic hinges at mid-span and central support sections was reasonably close to the experimental failure load. Higher Education of Libya (972/2007). 2019-02-27T10:02:25Z 2019-02-27T10:02:25Z 2018-12-01 2018-08-20 2018-08-30 Article Accepted manuscript Araba AM and Ashour AF (2018) Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams. Composites Part B: Engineering. 154: 321-336. http://hdl.handle.net/10454/16853 en https://doi.org/10.1016/j.compositesb.2018.08.077 Crown Copyright © 2018 Published by Elsevier Ltd. All rights reserved. Reproduced in accordance with the publisher's self-archiving policy. This manuscript version is made available under the CC-BY-NC-ND 4.0 license.
collection NDLTD
language en
sources NDLTD
topic Glass fiber reinforced polymer (GFRP)-steel
Reinforced concrete continuous beams
Flexural performance
spellingShingle Glass fiber reinforced polymer (GFRP)-steel
Reinforced concrete continuous beams
Flexural performance
Araba, Almahdi M.A.A.
Ashour, Ashraf F.
Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams
description Yes === This paper presents the experimental results of five large-scale hybrid glass fiber reinforced polymer (GFRP)-steel reinforced concrete continuous beams compared with two concrete continuous beams reinforced with either steel or GFRP bars as reference beams. In addition, two simply supported concrete beams reinforced with hybrid GFRP/steel were tested. The amount of longitudinal GFRP, steel reinforcements and area of steel bars to GFRP bars were the main investigated parameter in this study. The experimental results showed that increasing the GFRP reinforcement ratio simultaneously at the sagging and hogging zones resulted in an increase in the load capacity, however, less ductile behaviour. On the other hand, increasing the steel reinforcement ratio at critical sections resulted in more ductile behaviour, however, less load capacity increase after yielding of steel. The test results were compared with code equations and available theoretical models for predicting the beam load capacity and load-deflection response. It was concluded that Yoon's model reasonably predicted the deflection of the hybrid beams tested, whereas, the ACI.440.1R-15 equation underestimated the hybrid beam deflections. It was also shown that the load capacity prediction for hybrid reinforced concrete continuous beams based on a collapse mechanism with plastic hinges at mid-span and central support sections was reasonably close to the experimental failure load. === Higher Education of Libya (972/2007).
author Araba, Almahdi M.A.A.
Ashour, Ashraf F.
author_facet Araba, Almahdi M.A.A.
Ashour, Ashraf F.
author_sort Araba, Almahdi M.A.A.
title Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams
title_short Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams
title_full Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams
title_fullStr Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams
title_full_unstemmed Flexural performance of hybrid GFRP-steel reinforced concrete continuous beams
title_sort flexural performance of hybrid gfrp-steel reinforced concrete continuous beams
publishDate 2019
url http://hdl.handle.net/10454/16853
work_keys_str_mv AT arabaalmahdimaa flexuralperformanceofhybridgfrpsteelreinforcedconcretecontinuousbeams
AT ashourashraff flexuralperformanceofhybridgfrpsteelreinforcedconcretecontinuousbeams
_version_ 1719489516158320640